Search results for: 'Can I'
-
T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASKREFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More -
L-4890 TRUTZSCHLER TC-03 CARDING MACHINES, WITH DFK CHUTES & AUTO CAN CHANGER, YEAR 2005REFERENCE NUMBER: L-4890
Learn More
BRAND: TRUTZSCHLER
MODEL: TC-03
YEAR: 2005
QUANTITY: 1 -
K-3843 KAPOK FILLING MACHINEREFERENCE NUMBER: K-3843 KAPOK FILLING MACHINE STUFFING MACHINE AND BLOWER KAPOK FEEDING HOPPER AIR COMPRESSOR QUANTITY AVAILABLE: 1 Learn More -
M-5202 KB10 REBEAMER FOR ACETATE WITH DISK BRAKES - TSUDAKOMAREFERENCE NUMBER: M-5202 (1313VTYFXX12) L KB10 REBEAMER FOR ACETATE WITH DISK BRAKES - TSUDAKOMA QUANTITY AVAILABLE: 1 Learn More -
M-1943 BELT PUNCHING LINE YEAR 1996 (DYE CUTTER WITH CONVEYOR TRANSPORT)REFERENCE NUMBER: M-1943
BELT PUNCHING LINE YEAR 1996 (DYE CUTTER WITH CONVEYOR TRANSPORT)
BRAND: HANDSAEME
SIZE: 2250mm X 2000mm – HYDRAULIC POWER OF 150 TONS
PUNCHING IS DONE ON A TRANSPORT BELT.
PUNCHING ADJUSTABLE HEIGTH TILL 200mm
PRESSURE CAN BE ADJUSTED
PRESSURE IS DELIVERED BY A HYDRAULIC GROUP IN CONNECTION WITH A MECHANICAL LEVER
CAN BE USED ON FOAM
SOME DYES INCLUDED
NEW DYES CAN BE ORDERED
IN EXCELLENT CONDITION, USED ONLY OCCASIONALLY
Learn More -
M-5064 TSUDAKOMA WIDE WIDTH WATER JET WEAVING LOOMS FOR ACETATE YEAR 2006 WIDTH 3400mmREFERENCE NUMBER: M-5064 (121225HTJ11UX) L TSUDAKOMA WIDE WIDTH WATER JET WEAVING LOOMS FOR ACETATE YEAR 2006 WIDTH 3400mm TSUDAKOMA WATER JET LOOMS MANUFACTURING YEAR: 2006 WIDTH: 3400mm 2 WEFT FEEDERS CRANK SHEDDING 6 SHAFTS THESE LOOMS ARE SPECIAL EXECUTION OF TSUDAKOMA SPECIALLY PRODUCED FOR WIDE WIDTH WATER JET WEAVING SAMPLE WARP CAN BE SIZED FOR TRIAL AND CUSTOMER CAN SEE IT DURING RUNNING IF REQUESTED, 1 PIECE BEAM CAN ALSO BE SUPPLIED FOR ACETATE RUNNING NOW AT 450ppm AT 95% EFFICIENCY INCLUDES 1.5 PCS BEAM AND 1 PC REED QUANTITY AVAILABLE: 36 Learn More -
P-2121 RIETER D30 DRAW FRAMES YEAR 2001REFERENCE NUMBER: P-2121 RIETER D30 DRAW FRAMES YEAR 2001 RIETER TYPE: D30 DRAW FRAMES YEAR: 2001 SUITABLE FOR COTTON, POLYESTER OR MIXED UP TO 80mm SPEED 250 to 1000 M/MIN DRAFTING 3 OVER 3 PRESSION BAR REGULATION – ELECTRONIC INTEGRATED DUST ASPIRATION AUTOMATIC CAN CHANGER 18 INCHES x 42 INCHES CAN SIZE CREEL WITH SENSORS RIETER QUALITY MONITORS VOLTAGE: 220 VOLTS, 60 HERTZ 11.6 KILOWATTS POWER PNEUMATIC DRAFTING SYSTEM RSB D30 YEAR 2001 CARDS: C 1/2 – 1976 - COTTON C 1/3 – 1984 – POLYESTER C 1/3 – 1982 – POLYESTER ADDITIONAL DRAW FRAMES: 2 DO/2 YEAR: 1985 QUANTITY AVAILABLE: 2 Learn More -
TEXPA HEMMING AND LABEL SEWING MACHINES, MODEL QRSN RUNNING TERRYREFERENCE NUMBER: L-6890 TEXPA HEMMING AND LABEL SEWING MACHINES, MODEL QRSN RUNNING TERRY ITEM 001 TEXPA LONGITUDINAL HEMMING MACHINE YEAR 2005 QUANTITY: 1 ITEM 002 TEXPA CROSS HEMMING AND LABEL SEWING MACHINE YEAR: 2005 MODEL: QRSN POSSIBILE TO SEW THREE TYPES OF LABELS: U, V, FLAG PFAFF SEWING MACHINES EQUIPPED FOR TERRY TOWEL WORKING WIDTH: 300mm TO 2000mm QUANTITY: 1 STATUS: STOPPED, NOT DISMANTLED DELIVERY: DISMANTLING AND LOADING WILL NEED 3 WEEKS, REQUIRES TWO 40 FT CONTAINERS TO SHIP Learn More -
T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTERREFERENCE NUMBER: T-6545
MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
PRODUCT INTRODUCTION:
MASK BACTERIA FILTRATION EFFICIENCY KEY PERFORMANCE INDICATORS (BFE) DETECTOR TESTER NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASKS TECHNOLOGY YY0469-2011 APPENDIX B IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST B. 1.1.1 TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL ASTMF2100, ASTMF2101, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING,IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENTIFIC RESEARCH INSTITUTES, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY.
EXECUTION STANDARD:
Q/0212 ZRB003-2015 MEDICAL SURGICAL MASK
BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR RELATED INTELLECTUAL PROPERTY:
NO.: ZL200820224142.6 ELECTRIC FLOW CONTROL VALVE
NO.: ZL200820224143.0 GAS CAPACITY
NO.: ZL200920308391.8 AIR FILTRATIONMATERIAL FILTRATION EFFICIENCY DETECTOR
PRODUCT FEATURES:
NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS;
BUILT -IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET, A, B TWO -WAY, SIX ANDERSEN; THE PERISTALTIC PUMP FLOW CAN BE SET;
THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD.
EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL; 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN;
USB INTERFACE, SUPPORT U DISK DATA STORAGE;
CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS; BUILT-IN LEAKAGE PROTECTION SWITCH TO PROTECT THE SAFETY OF OPERATORS;
THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT.
THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE.
DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT; SUPPORTING AND MOVING DUAL PURPOSE CASTERS.
QUANTITY: 1
Learn More -
T-6575 NON-INVASIVE VENTILATORNON-INVASIVE VENTILATOR
Learn More
CERTIFICATE: CE
MEDICAL VENTILATOR
TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
VENTILATOR TYPE: ELECTRIC CONTROL
SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
*VENTILATION MODE: CPAP, S, S/T, T
PRESSURE RANGE:
PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
PRESSURE ACCURACY: + 0.5CMH2O
PARAMETER SETTING:
DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
INSPIRATORY PHASE PRESSURE: 4-30CMH2O
EXPIRATORY PRESSURE: 4-30CMH2O
EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
INSPIRATORY SENSITIVITY: 1-8 STALLS
EXPIRATORY SENSITIVITY: 1-8 STALLS
RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
INSPIRATORY TIME: 0.3-3.0S
BACKUP RATE: ON / OFF, DEFAULT 10
PRESSURE RISE TIME: 1-4 STALLS
HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
*TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
*DATA MANAGEMENT:
NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
PARTS:
SD CARD: STANDARD
SD CARD SLOT: STANDARD
PIPING: 9 22MM, 1.8M LONG
FACE SHIELD: F2 NOSE MASK AS STANDARD
NOISE: LESS THAN 30DB
ENVIRONMENT CONDITION:
TEMPERATURE:
(WHEN USED) 5 -35 C
(DURING TRANSPORTATION AND STORAGE) -20 C -55 C
ATMOSPHERIC PRESSURE:
(WHEN USED) 760-1060HPA
(DURING TRANSPORTATION AND STORAGE) 760-1060HPA
WORKING HOURS: MORE THAN 8 HOURS
POWER SUPPLY REQUIREMENTS:
AC VOLTAGE: 100-240V
FREQUENCY: 50HZ/60HZ
INPUT POWER: LESS THAN 2A
WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
INSTRUMENT SIZE: 290mm X 180mm X 134mm
WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
ITEM 001
QUANTITY: 10 SETS-999 SETS
ITEM 002
QUANTITY: 1,000 SETS-9,999SETS
ITEM 003
QUANTITY: ≥10,000 SETS