Search results for: 'and ma'
-
T-9596 BUTTON PULL TEST MACHINET-9596 BUTTON PULL TEST MACHINE FEATURE: 1. SNAP BUTTON PULL TEST MACHINE IS A SIMPLE BUT EFFECTIVE DESIGN MAINLY CONSISTING OF A HIGH PRECISION GAUGE, A STURDY REQUIRED BY STANDARDS & REGULATIONS IS BE FIXED HORIZONTALLY (CONSTANT FORCE IS APPLIED TO SECURE THE SAMPLE) SO THAT SNAP OR OTHER ACCESSORIES ATTACHED IN FABRIC CAN BE CLAMPED INTO. 2. MOREOVER, A STANDARD WEIGHT IS ALSO OFFERED SO THAT IT CAN BE REGULARLY CHECKED IF IT MEETS THE SAFETY REQUIREMENTS. 3. THE CAPABILITY OF THE BUTTON PULL TEST MACHINE CAN BE ENHANCED WITH CLAMPS & ACCESSORIES FOR TESTING OF OTHER SNAPS, JEAN BUTTONS, FOUR HOLE BUTTONS & GARMENTS ACCESSORIES SUCH AS ZIPPERS, BOWS, APPLIQUÉ, TOGGLES, HOOKS/BARS, AND D-RINGS, AMONGST OTHERS. SPECIFICATION: DIMENSIONS: 260 X 310 X 820mm NET WEIGHT: 32KG ACCESSORIES: STANDARD ACCESSORIES 1PC - IMADA FORCE GAUGE FB-30K 1PC - UPPER UNIVERSAL GRIP 1PC - UPPER STUD GRIP 1PC - LOWER FABRIC CLAMP & LEVEL ARM LOCKING 1PC - LOWER GRASP BUTTON ACCESSORY KIT 1PC - CALIBRATION WEIGHT 15LB 1PC - THREE PRONGED GRIP 1PC - UPPER LONG NOSE VISE GRIP Learn More -
T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENTREFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More -
YY-2183 OZONE AGING TEST CHAMBER, TEMPERATURE RANGE RT +10°C ~ 60°CYY-2183 OZONE AGING TEST CHAMBER, TEMPERATURE RANGE RT +10°C ~ 60°C DETAILS: IT IS WIDELY USED TO MEASURE QUALITY CONTROL; RUBBER & PLASTICS; AUTOMOBILE PRODUCTION; WIRES AND CABLES; PACKING MATERIALS; INSTRUMENTS AND MEASURING DEVICES; MEDICAL EQUIPMENT; CIVILIAN NUCLEAR ENERGY; CIVIL AVIATION; COLLEGES AND UNIVERSITIES; RESEARCH LABORATORIES; INSPECTION ARBITRATION, AND TECHNICAL SUPERVISION DEPARTMENTS AND OTHER PRODUCTS. CORRESPONDING STANDARDS: JIS K 6259, ASTM1149, ASTM1171, ISO1431, DIN53509, GB/T13642, GB/T 7762-2003, GB 2951. QUANTITY: 1 Learn More -
T-6546 PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKREFERENCE NUMBER: T-6546PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKINTRODUCTIONMEDICAL SURGICAL MASK PARTICLE FILTRATION EFFICIENCY PFE TESTER IS SUITABLE FOR MEDICAL INSTRUMENT INSPECTION CENTER, SAFETY PROTECTION INSPECTION CENTER, LABOR PROTECTION INSPECTION CENTER, DRUG INSPECTION CENTER, DISEASE PREVENTION AND CONTROL CENTER, TEXTILE INSPECTION CENTER, HOSPITAL, MASK AND RESPIRATOR MANUFACTURERS, ETC.FEATURESTHE PFE TESTER FOR PARTICLE FILTRATION EFFICIENCY OF SURGICAL MASKS IS EQUIPPED WITH A SPECIAL SALT AEROSOL GENERATOR, WHICH CAN PRODUCE AEROSOLS WITH SPECIFIC PARTICLE SIZE AND CONCENTRATION.EQUIPPED WITH A SERIES OF SPECIAL FIXTURE, SUITABLE FOR THE DETECTION OF ALL KINDS OF MASKS.BUILT-IN HIGH LIFE PHOTOMETER MODULE, SAMPLING TIME ACCUMULATION, PROMPT LIGHT CLEANING.AUTOMATIC CONTROL OF AEROSOL GENERATION, AUTOMATIC CALCULATION OF CAPTURE EFFICIENCY AND MASK AIRFLOW RESISTANCE, REDUCE HUMAN INTERVENTION.BUILT-IN HIGH PRECISION ELECTRONIC FLOWMETER AND HIGH PERFORMANCE SAMPLING PUMP TO ENSURE FLOW STABILITY.PARAMETERTEST FLOW: PARAMETER RANGE: (5 ~ 100) L/MIN; RESOLUTION: (5 ~ 100) L/MIN;MAXIMUM ALLOWABLE ERROR: ±1%PRESSURE DETECTION RANGE: PARAMETER RANGE: (0 ~ 2500) PA; RESOLUTION: 0.1PA; MAXIMUM ALLOWABLE ERROR: ±1%CONCENTRATION DETECTION RANGE: PARAMETER RANGE: (0.001 ~ 100) 0 G/L;DETECTION ACCURACY: 1% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100%DETECTION REPEATABILITY: 5% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100% MEDIAN DIAMETER OF SALT AEROSOL PARTICLES (CMD): (0.075±0.02)MMEDIAN AEROSOL PARTICLE NUMBER DIAMETER (CMD) (OPTIONAL): (0.185±0.02) MOPERATING TEMPERATURE: 20±5CLearn MoreINSTRUMENT NOISE: <60DB(A)POWER SUPPLY: AC220V±10%, 50HZMAIN MACHINE SIZE: (LENGTH 700 X WIDTH 720 X HEIGHT 1450) mmQUANTITY: 1 -
T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More -
T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASKREFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More -
T-9597 FABRIC BURSTING STRENGTH TESTERT-9597 FABRIC BURSTING STRENGTH TESTER KEY SPECIFICATION: RANGE: 2.00MPA TO 10.000MPA THE MIN. DIVISION VALUE: 0.001MPA TO 0.003MPA TEST AREA: 73mm2 (Φ30.5mm), 100mm2 (Φ35.7mm), 500mm2 (Φ79.8mm), 1000mm2 (Φ112.8mm) CAN BE OPTION THICKNESS OF RUBBER DIAPHRAGM: ≤2mm PRESSURE SPEED: 20ML/MIN - 600ML/MIN MAXIMUM EXPANSION HEIGHT: 75 ± 0.02mm TESTING UNITS: KPA, KGF/ CM2, ATM, MMHG, LB/IN2 FREE SHIFT TEST METHOD: CONSTANT RATE BURSTING CONSTANT EXPANSION CONSTANT PRESSURE CONSTANT TIME BURSTING OUTPUT: PRINTER, DISPLAY OUTPUT AND CAN BE CONNECTED TO THE COMPUTER POWER SUPPLY: AC 220V 50/60HZ 200W DIMENSIONS: 550 × 450 × 700mm NET WEIGHT: 125KG Learn More -
T-9599 PERSPIROMETER / PERSPIRATION FASTNESS TESTERT-9599 PERSPIROMETER / PERSPIRATION FASTNESS TESTER KEY SPECIFICATION: WEIGHTS: A: 3.63KG (8LB), B: 0.45 (1LB), C: 0.90KG (2LB, PALLET) AATCC LOAD: A+C=10LB ISO LOAD: A+B+C=11LB DIMENSIONS: 165 X 75 X 145mm (L X W X H) WEIGHT: 8 KG Learn More -
T-9598 TEXTILE COLOR FASTNESS TO WASHING TESTERT-9598 TEXTILE COLOR FASTNESS TO WASHING TESTER KEY SPECIFICATION: CUP COMPOSITE MODE: 2A+2B, 4A+4B, 6A+6B, 8A+8B, 8A+12B, 12A, 8B, CUSTOMIZED AATCC CUP VOLUME (A): 1200ML ISO CUP VOLUME (B): 550ML CONTROL MODE: LCD COUNTER DISPLAY ROTATION SPEED: 40±2 RPM TEMPERATURE CONTROL RANGE: RT TO 100℃ HEATING METHODS: ELECTRICAL HEATING STAINLESS STEEL BALLS:¢6mm STAINLESS STEEL DRY CLEANING DISCS:¢30mm, THICKNESS: 3mm, MASS: 20G POWER SUPPLY: 3∮AC 380V 50/60Hz PACKED DIMENSIONS: 890 x 690 x 1200mm PACKED WEIGHT: 130 KG Learn More -
T-9593 CROCKMETER RUBBING FASTNESS TESTERT-9593 CROCKMETER RUBBING FASTNESS TESTER CROCKMETER RUBBING FASTNESS TESTER SUPPLY CAPACITY 500 SETS COMES WITH A STANDARD WEIGHT (9 N) ARM THAT COMPLIES TO A VARIETY OF STANDARDS INCLUDING AATCC 8 AND 165 AND TRADITIONAL SAMPLE HOLDER. APPLICATION: CROCKMETER RUBBING FASTNESS TESTER TO DETERMINE THE COLOR FASTNESS OF TEXTILES TO DRY OR WET RUBBING. A PINNED ACRYLIC SAMPLE HOLDER ENSURES RAPID SAMPLE MOUNTING AND REPEATABILITY OF RESULTS. FEATURE: 1. METAL BOX, HIGH-TEMPERATURE BAKING COATING, EASY MAINTENANCE. 2. ELECTRIC MOTOR, FITTED WITH A PRE-DETERMINED ELECTRONIC COUNTER FOR STROKES UP TO 9999, EXPERIMENT COMPLETE SUCCESSFULLY, AUTOMATIC STOP. Learn More