NovaStar, SS101, 2020, 500kW, 440V, 60Hz, Condensing Steam Turbine Generator (New)

Description

  1. Technical Parameters
    1. Model: SS101
    2. Rated power: 500 kW
    3. Inlet steam pressure: 1.0 ± 0.1 MPAA
    4. Inlet temperature: 184 (+10 -5) °C
    5. Exhaust steam pressure: 0.015 MPAA
    6. Rated steam flow: 6 t/h
    7. Rated speed: 7500 rpm
    8. Critical speed: 12500 rpm
    9. Gear box: 7500/1500
    10. Number of impellers: 3
    11. Material: ZG25A front cylinder, ZG25A steam room, 35CrMoA blade, 35CrMoA impeller, 35CrMoA main shaft, HT250 front and rear bearing seat, ZG25A main steam valve, DN100/DN600 steam pipe
    12. Over speed protection: 10000 to 10100 rpm
    13. Over speed response time: 1 s
    14. Vibration: ≤ 0.07 mm
    15. Speed control: 1000 to 10000 rpm
    16. Noise: ≤ 90 dB
    17. Continuous running time: ≥ 8000 h
    18. Lube oil: L-TSA46 steam turbine oil
    19. Max axial displacement: 0.7 mm
    20. Alarm temperature of bearing: 80/90 °C
    21. Max temperature of lube oil: 70 °C
    22. Coupling: solid coupling
    23. Dimensions: 2000 × 1200 × 2000 mm
  2. Condenser
    1. Cooling area: 100 m²
    2. Cooling water: normal 27 °C / max 33 °C
    3. Water pressure: ≥ 3 kg/cm²
    4. Water flow: 320 t/h
    5. Diameter: DN125/DN125
    6. Material: 304 stainless steel pipe
    7. Dimensions: Φ 1200 × 2500 mm
    8. Flow: 6 t/h
    9. Head: 35 mH2O
  3. Generator Parameters
    1. Rated power: 0.6 MVA
    2. Power: 0.5 MW
    3. Voltage: 440 V
    4. Speed: 1500 r/min
    5. Frequency: 60 Hz
    6. Efficiency: ≥ 90%
  4. Scope of Supply
    1. Front cylinder – 1
    2. Rear cylinder – 1
    3. No. 1 stage diaphragm plate – 1
    4. No. 2 stage diaphragm plate – 1
    5. Nozzle – 1
    6. Front bearing seat – 1
    7. Rear bearing seat – 1
    8. Rear bearing – 1
    9. Thrust front bearing – 1
    10. The spindle assembly – 1
    11. The first stage impeller blades – 1
    12. Secondary impeller blades – 1
    13. The third stage impeller blades – 1
    14. Chassis – 1
    15. The turbine end coupling – 1
    16. The generator end coupling – 1
    17. The turbine end coupling shield – 1
    18. The generator end coupling shield – 1
    19. Reduction gear – 1
    20. Quickly closing the main valve – 1
    21. Regulating system assembly – 1
    22. Protection system assembly – 1
    23. Extraction system assembly – 1
    24. Exhaust steam over – 1
    25. Hydrophobic expansion tank – 1
    26. Pipe line – 1
    27. Condenser framework – 1
    28. Security template – 1
    29. Soda line – 1
    30. Ejector – 2
    31. Condensate pump – 2
    32. AC motor – 2
    33. Steam turbine thermal control cabinet – 1
    34. PI pressure gauge PL – 1; inlet steam
    35. PI pressure gauge PL – 1; steam condenser chamber
    36. PI pressure gauge PL – 2; condensate pump discharge
    37. PI pressure gauge PL – 1; ejector
    38. PI pressure gauge PL – 2; import and export of circulating water
    39. TE the thermal resistance – 1; admission
    40. TE the thermal resistance – 1; exhaust steam
    41. TI the thermometer – 2; condenser in and out of the water
    42. TI the thermometer – 1; condenser hot well
    43. TI the thermometer – 1; steam condenser chamber
    44. Temperature display instrument – 1; admission
    45. Temperature display instrument – 1; exhaust steam
    46. PT100 resistance thermometer, with local display – 2; steam turbine bearing temperature before and after
    47. Intelligent tachometer – 1
    48. Speed sensor – 1
    49. Spanner of emergency generator – 1
    50. Turning gear tools – 1
    51. Lifting tools of cylinder & rotor – 1
    52. Lifting tools of diaphragm plate – 1
    53. Rear bearing – 1; the steam turbine
    54. Thrust front bearing – 1; the steam turbine
    55. Oil seal – 4; the steam turbine