Galileo, Vacuum Metallizer, 1650mm Working Width, 19 Evaporators

Description

  1. Overview
    1. Inventory number: E-7192
    2. Galileo metalizing unit
    3. 1650 mm
    4. Pictures available
  2. Materials
    1. Polyester (PET): 10 - 60
    2. Oriented polypropylene (OPP): 15 - 100
    3. PVC: 20 - 80
    4. High-density polyethylene (HDPE): 20 - 120
    5. CPP: 25 - 80
    6. Also able to metalize low density polyethylene (LDPE), polyamide (PA) and cellophane with thicknesses depending upon the specific material and the tension range of the machine
    7. All materials must be suitable for vacuum metallizing
    8. Paper suitable for vacuum metallization: 40 - 90 gr/m2
    9. Maximum volatile content (ASTM 0644/55): 3.5%
  3. Roll Dimensions
    1. Maximum metallizing width: 1650 mm
    2. Minimum metallizing width: 800 mm
    3. Maximum diameter: 1000 mm
    4. Internal core diameter: 150 mm
  4. Evaporation
    1. Material: aluminum
    2. Recommended degree of purity: 99.8%
    3. Diameter of the aluminum wire: 1.6 mm
    4. Number of evaporators: 19
    5. Dimensions: 120 x 35 x 10 mm
    6. Material: inter-metallic sintered
    7. Maximum range of thickness deposited: 0.8 - 10
  5. Pumping System
    1. Pumps installed in metalizing chamber
      1. Two diffusion pumps: 30,000 I/s
      2. One mechanical booster pump: 2400 m3/h
      3. One cryogenic panel for LN2 or closed circuit chilling unit (Polycold - PFC 1100 HC): 150,000 I/s
      4. One rotary piston pump: 505 m3/h
    2. Pumps installed in winding chamber
      1. One mechanical booster pump: 13,000 m3/h
      2. One mechanical booster pump: 5500 m3/h
      3. One mechanical booster pump: 2000 m3/h
      4. One cryogenic panel for LN2 or closed circuit chilling unit (Polycold - PFC 11 HC): 150,000 L/s
      5. Two rotary piston pumps: 505 m3/h
    3. Pumps installed in guard chamber
      1. One mechanical booster pump: 2000 m3/h
      2. One mechanical booster pump: 1000 m3/h
  6. Utilities
    1. Electrical supply
      1. Voltage (+/- 10%): as requested by the customer
      2. Frequency (+/- 4%): as requested by the customer
      3. Phases: 3
      4. Wires: 3 + PE
      5. Maximum absorbed power (for basic unit): 270 kW
      6. Main circuit breaker (based on 400 V, 50 Hz): 580 A
    2. Cooling water
      1. Flow rate (for basic unit): 350 L/min
      2. Inlet temperature: 15 ÷ 25° C
      3. Inlet pressure (for free outlet): 3 kg/cm2