Solar, Taurus 60, Cogeneration Plant, 4950 kWe, 6300V, 50Hz

Description

  1. Overview
    1. The gas turbine engine gearbox alternator went through a major overhaul in 2008
    2. Shut down in 2009
  2. Gas Turbine Specifications
    1. 4950 kW
    2. 6300 V, 50 Hz
    3. Stand power: 4950 kWe G/L NGP
    4. RPM: 14944 @ 50 Hz
    5. IGV setting: 5.0 T5
    6. Base: 1206F G/L set point full load: 1250F
  3. Alternator Specifications
    1. Make: Leroy Somer
    2. Type: SA 56 BUL85-4P
    3. IP: 21
    4. Power: 4800 kW (6000 kVA)
    5. PF: 0.8
    6. Volts: 6300
    7. Amps: 549.8
    8. RPM: 1500 @ 50 Hz
    9. Temp: 40 deg. C ambient
  4. Hrsg Specifications
    1. Make: Moiman SA
    2. Type: Cenerdor
    3. Vapor pressure: 13 kg/cm2
    4. Volume: 33.5 cubic meters
    5. Temp service: 250 deg. C
  5. Included Equipment
    1. Air compressors
    2. Transformer gas compressor
    3. Refrigeration compressor