Description Overview Two heavy fuel oil generator sets: one Wartsila 4.0 MW and one MAN B&W 3.8 MW List number: H-1360 Generator Set Specifications Dg 1: Wartsila, 4000 kW, 11 kV / 50 Hz, alternator by BHEL, commissioned January 1999 Dg 3: MAN B&W, 3800 kW, 11 kV / 50 Hz, alternator by AVK, commissioned June 1998 Both can be operated on furnace oil or HSD Waste Heat Recovery Boilers Boiler no. 1: Thermax, MCR 2.5 T/hr, working pressure 10.5 kg/cm², temperature 170°C, chimney 52 m, commissioned July 1999 Boiler no. 3: Thermax, MCR 2.5 T/hr, working pressure 10.5 kg/cm², temperature 170°C, chimney 52 m, commissioned July 2000 Cooling towers by Mihir Cooling Towers Ltd. Running Hours Dg 1 (Wartsila 4.0 MW): 67,024 hours Dg 3 (MAN B&W 3.8 MW): 61,376 hours Last Major Overhaul Running Hours Dg 1 (Wartsila 4.0 MW): 56,000 hours Dg 3 (MAN B&W 3.8 MW): 54,000 hours