Four turbine-generator units with associated boilers and emission control equipment.
Unit 1 on line year 1949, unit 2 on line year 1953, unit 3 on line year 1962, unit 4 on line year 1969.
Turbine-Generator Specifications
Unit 1: Westinghouse, generator nameplate 7,500 kW, maximum gross capability 10,000 kW, 13,800 volt, air cooled, condensing single flow, 3600 rpm.
Unit 2: Westinghouse, generator nameplate 11,500 kW (turbine 22,000 kW), maximum gross capability 14,000 kW, 13,800 volt, air cooled, condensing single flow, 3600 rpm.
Unit 3: Westinghouse, generator nameplate 25,000 kW, maximum gross capability 25,000 kW, 13,800 volt, hydrogen cooled, condensing single flow, 3600 rpm.
Unit 4: General Electric, generator nameplate 54,400 kW, maximum gross capability 60,000 kW, 13,800 volt, hydrogen cooled, condensing single flow, 3600 rpm.
Boiler Specifications
Unit 1: Riley boiler, bituminous coal or natural gas fuel, pulverized coal burners, maximum coal burn rate 10,000 pounds/hr, unit heat input 115.5 mmbtu/hr, steaming capacity 90,000 lb/hr, steam conditions 625 psig/830-f.
Unit 2: Riley boiler, bituminous coal or natural gas fuel, pulverized coal burners, maximum coal burn rate 15,000 pounds/hr, unit heat input 152.7 mmbtu/hr, steaming capacity 120,000 lb/hr, steam conditions 625 psig/830-f.
Unit 3: Babcock & Wilcox boiler, bituminous coal or natural gas fuel, pulverized coal burners, maximum coal burn rate 25,000 pounds/hr, unit heat input 284.5 mmbtu/hr, steaming capacity 220,000 lb/hr, steam conditions 875 psig/905-f.
Unit 4: Babcock & Wilcox boiler, bituminous coal or natural gas fuel, pulverized coal burners, maximum coal burn rate 52,000 pounds/hr, unit heat input 614.5 mmbtu/hr, steaming capacity 520,000 lb/hr, steam conditions 1350 psig/955-f.
Cooling Water
Unit 1: once through river water 11,000 gpm, cooling towers n/a.
Unit 2: once through river water 14,500 gpm, cooling towers n/a.
Unit 3: once through river water 22,000 gpm, cooling towers 22,000 gpm.
Unit 4: once through river water 25,000 gpm, cooling towers 41,000 gpm.
Emission Control Equipment
Unit 1: cyclone type, manufacturer UOP, continuous emission monitors for so2 and opacity.
Unit 2: cyclone and electrostatic precipitator type, manufacturer UOP, continuous emission monitors for so2 and opacity.
Unit 3: cyclone and electrostatic precipitator type, manufacturer UOP/field service, continuous emission monitors for so2 and opacity.
Unit 4: so2 particulate control mfgr cbeec dry scrubber pulsed jet fabric filter; nox control mgr mobotec rotating opposed fire air (rofa) urea injection (sncr); continuous emission monitors for so2, nox, co2, opacity.
Miscellaneous
Maximum daily burn: 1,000 tons.
Unloading capability: 1,500 tons per day.
Site storage capacity: 85,000 tons.
Site elevation: 985.5 feet above sea level.
Elevation of chimney for unit 4: 1285.5 feet above sea level.
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.