Wartsila, Vasa 16V32, 1989, 5.3 MW, HFO Generator Set, 750 RPM

Description

  1. Overview
    1. Quantity: 3 complete diesel generator sets.
    2. Engine make: Wartsila Diesel.
    3. Engine model: Vasa 16-V-32(D).
    4. Engine capacity: 6000 kW.
    5. Date of manufacturing: 1989.
    6. Engine rpm: 750.
    7. Compression ratio: 12:1.
    8. Fuel: HSD and HFO.
  2. Engine Components
    1. Engine governor make: Woodward, type: PGG.
    2. Fuel pump: electrical drive 2.2 kW (Stromberg), pump model: IMO AEC-038N2, NTBP.
    3. Turning gear (each DG set): turning gear motor Kirloskar, frame BPM100L, 2.2 kW, rpm 1400; turning gear make Katsa Vaihde Tampere (Finland), ratio 272:1.
    4. Turbocharger (two turbochargers per DG set, total 6): model VTR-354-11, VTR exhaust gas turbocharger, make ABB Switzerland.
  3. Alternator
    1. Make: Leroy Somer.
    2. Type: PA-160 G 115-958P.
    3. Serial numbers: 156998-2 for DG-1, 156998-3 for DG-2, 156998-1 for DG-3.
    4. Capacity: 5800 kW, 7250 kVA.
    5. Rpm: 750.
    6. Duty: S1.
    7. Date of manufacturing: January 1989.
    8. Voltage: 6600 volts.
    9. Insulation class: F, A-634.2.
    10. Power factor: 0.8.
  4. Heat Exchangers
    1. Lub oil heat exchanger (one per DG set): make Alfa Laval, plate heat exchanger, type M-15 BFM8, max working pressure 10 kg/cm², max temp 100 °C, manufacturing year 2001, ΔT 06-10 °C.
    2. Jacket water heat exchanger (one per DG set): make Alfa Laval, plate heat exchanger, type M15-BFM8, working pressure 10.0 kg/cm², max temp 100 °C, manufacturing year 2001, ΔT 06-10 °C.
  5. Separators
    1. Fuel separator for HSD (one unit, common for all 3 DG sets): make Alfa Laval, manufacturer Alfa Laval India, motor 7.5 kW (CG), flame proof induction motor.
  6. Cooling Tower
    1. One cooling tower per DG set.
    2. Make: Paharpur Cooling Tower Limited.
    3. Model: 375-103 T.O.
    4. Type: cross flow cooling tower.
    5. Gearbox model: 22.2 series.
  7. Tanks
    1. HFO main storage tank: capacity 300 kL, height 7.5 m, diameter 7.5 m, indirect oil heater 18 kW x 2 (one standby), insulated tank with water sprinkler system.
    2. HFO settling tank: heat insulated tank, storage capacity 30 kL, height 5.0 m, diameter 3.0 m, indirect oil heater 3.0 kW x 2, with water sprinkler system.
    3. HFO day tank: capacity 25 kL, height 4.0 m, diameter 3.0 m, indirect oil heater 3.0 kW x 2, heat insulated tank with water sprinkler system.
    4. HSD main storage tank: capacity 100 kL, height 5.5 m, diameter 5.5 m, with water sprinkler system (not for sale).
    5. HSD settling tank: capacity 10 kL, height 2.5 m, diameter 2.5 m, with water sprinkler system.
    6. HSD day tank: (details not provided).
  8. Condition and Run Hours
    1. DG-1: current reading 65247.52 hours, last overhaul reading 65127 hours, last running date 12/12/2013, prime condition yes, remark: 8000 hours overhauling done on 1/10/2011.
    2. DG-2: current reading 64395.47 hours, last overhaul reading 63219 hours, last running date 28/01/2014, prime condition yes, remark: 8000 hours overhauling done on 2/12/2010.
    3. DG-3: current reading 62335.22 hours, last overhaul reading 62114 hours, last running date 31/01/2014, prime condition yes, remark: 4000 hours overhauling done on 20/4/2012 after 8000 hours overhauling done on 3/8/2008.