Huaxiatex, Detector, 220V AC, 7-Plug Connection, Yarn Breakage Detection

Description

  1. Overview
    1. Seven-pin plug connection, plug can work.
    2. "1" line and "2" line are used to connect in 220 V ac power.
    3. "3" line and "4" line connected express.
    4. "5" line and "6" line connected to the output signal is normally closed.
    5. "6" line and "7" line connected to the output normally open signal.
    6. Transmitter head is a three-pin plug, receiving head is four-pin plug, plug can work.
    7. Fluff detector is inserted five-pin plug.
  2. Panel Function Keys
    1. Keys: "up", "down", "esc", "ent".
    2. When connected to ac 220 v power, the monitor has power, the display says 0000 and blinks.
    3. Launch tube beam receiver must be aligned to the center position when driving to ensure the emitted light points do not pull, otherwise malfunction.
    4. After driving, "3" and "4" feet become normally closed, while the display stops flashing and displays "006" then dropped, meaning that after 6 seconds delay yarn breakage detection.
  3. Menu Key Functions
    1. Regular press "ent" key displays 001-018, total 18 menus.
    2. 001 represents the delay time setting, press "ent" to set, press "up" and "down" to adjust and press "ent" ok.
    3. The factory setting is 6 seconds.
    4. 002-003 represents 1-2 road on and off: press "ent" displays 001 means open, displays 000 means close, after settings, press "ent" key to confirm.
    5. 010-011 represents 1-2 road sensitivity adjustment, press "up" and "down" adjust and press "ent" ok.
    6. Each sensitivity factory setting is 530, the larger the number the higher the sensitivity.
  4. Operation Display
    1. After driving normally, the yarn panel displays the number of stops.
    2. The corresponding tubes light indicates all the way open, no light indicates off.
    3. Flashes had broken yarn signal, press "esc" cleared.