Description Overview Three turbogas cogenerators, 4 mw each Total capacity 12 mw Yearly electricity production capability is 100 mln kwh Deutz brand gas engines Specifications Each cogenerator has a dedicated boiler for steam generating Each cogenerator has a boiler for hot water production (85° celsius) Each cogenerator has an electric transformer high to medium voltage During power generation process, steam boiler uses hot exhaust gases from the engines to heat up water and generate steam Steam is sold at 12-15 atm via special pipes to 3 companies Hot water capacity is the output from the cooling system (at 85 degrees celsius); this heat is not being utilized at current time Control System The plant is commanded by a unique general electric board, controlled by a microprocessor