TurboTronic 4 control system with ControlLogix controller, standard display with discrete event log, strip chart, historical trend, maintenance screen, gas turbine and generator control, vibration and temperature monitoring, CGCM (combination generator control module) with load share, auto synchronization, voltage control, reactive power control, kW control
Integrated lube oil system with turbine-driven lube pump, pre/post lube pump, backup lube pump, air/oil cooler, integral lube oil tank, lube oil tank heater, oil mist eliminator, simplex lube oil filter
Documentation including drawings, quality control data book, inspection and test plan, test reports, operation and maintenance manuals
Factory testing of turbine and package
Optional Equipment
Generator options: standard voltages of 11,000 V (50 Hz); 12,470, 13,200 or 13,800 V (60 Hz)
Control system: auxiliary and remote display/control terminal, heat recovery application interface, serial link supervisory interface, turbine performance map, printer/logger, field programming terminal, unfired waste heat recovery system control (stand-alone panel), multi-unit applications: load shed control (stand-alone panel), import/export, kW/kVAR control (stand-alone panel)
Ancillary equipment: inlet and exhaust silencers, self-cleaning or prefilter/barrier air inlet filter, inlet evaporative cooler, inlet chiller coils
Nominal Performance
Output power: 15,000 kWe
Heat rate: 10,230 kJ/kWe-hr (9695 BTU/kWe-hr)
Exhaust flow: 179,250 kg/hr (395,180 lb/hr)
Exhaust temperature: 495°C (925°F)
Nominal rating per ISO at 15°C (59°F), at sea level, no inlet/exhaust losses, relative humidity 60%, natural gas fuel with LHV = 35 MJ/Nm³ (940 BTU/scf), no accessory losses
Engine efficiency: 35.2%
Standard and high ambient ratings available
Package Dimensions
Length: 14,021 mm (46' 0")
Width: 3327 mm (10' 11")
Height: 3302 mm (10' 10")
Approximate weight: 73,668 kg (162,409 lb) unenclosed dry weight
Left Side Connections
Lube oil: vent, drain, cooler
Generator control box, power
Drip pan drain
Package ground
DC power - electronic actuator
Generator monitor box
AC power - starter motor
Generator terminal box (line)
Turbine control box
Right Side Connections
Combustor and exhaust diffuser drain
Fuel: inlet, filter drain, vent
Package air supply with liquid fuel atomizing, self-cleaning filter, solenoid actuation
Turbine cleaning fluid inlet
AC power for liquid fuel primary pump, lube oil tank heater, pre/post lube oil pump
Air inlet duct drain
Package ground
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.