Dresser-Rand, 11900 kW Back Pressure Steam Turbine Generator Set, 1979, 60Hz, 13800V

Description

  1. Turbine
    1. 11900 kW Dresser-Rand (Turbodyne) multi valve
    2. Multi stage backpressure steam turbine
    3. 3600 rpm
    4. Inlet steam 390 psig
    5. 650 deg F (maximum 400 psig / 750 deg F)
    6. Maximum flow 234,000 lbs/hr
    7. Exhaust: 20 psig
    8. Steam rate: 20 to 21 lbs/kWh, 210,000 lbs/hr at 10,000 kW
    9. Normal rating: 10,000 kW
    10. Cw rotation looking from governor end
    11. Woodward UG40 governor
    12. Inlet size: 12” class 600, exhaust: 30” class 150 bottom
    13. Number of stages: 11
    14. Turning gear
  2. Generator
    1. EM 14875 kVA
    2. 11900 kW
    3. 13800 V
    4. 3 phase
    5. 60 Hz, TEWAC
    6. 3600 rpm
    7. 0.8 pf
    8. Field volts 125
    9. Field amps 12
    10. Brushless exciter
  3. History
    1. Unit manufactured 1979
    2. Unit installed: 1987
    3. Unit shutdown 2008
    4. Unit is rotated every week, still installed
    5. Last overhaul: 2007
  4. Scope Of Supply
    1. Steam turbine, trip and throttle valve, lube oil system, gland steam condenser, governor, gauge board mounted on common skid
    2. Generator with brushless exciter on skid
    3. Generator terminal box with 3 x surge arresters, 3 x capacitors, 3 x 800:5 neutral side CTs
    4. Neutral ground resistor
    5. Manual with drawings
    6. 3 x 14400:120 fused PTs
    7. MCC (to be verified later)
    8. 2 x exhaust safety valves
    9. Exhaust pipe (reduced from 30” x 20”) U shape around 15 feet long
    10. Special tool: generator skid pan
    11. 2 x EM voltage regulators
    12. Spare parts include spare UG-40 governor, bearings and other all available spare parts
  5. Shipping Size And Weight
    1. Turbine skid: 17’ long x 12’ 6” wide x 10’ height: 55,000 lbs
    2. Generator skid: 17’ long x 10’ wide x 10’ height: 110,000 lbs
    3. Parts: one flatbed truck 30,000 lbs