One synchronous brushless revolving field generator, with direct connected rotating brushless exciter
Type: 4 pole, 1800 rpm
Electrical rating: 770 kW, P.F. 0.8, 105/40 °C rise
3 ph, 60 hertz, 480 volts
Duty: continuous
Bearing design: double anti-friction
Enclosure: IP22 or IP23 open drip proof
Independent two bearing design type with shaft extension suitable for direct drive coupling
Includes automatic voltage regulator, PMG, VAR/PF controller, paralleling kit, space heaters
Turbine Generator Performance Guarantee
Skinner guarantees the steam turbine generator package will produce electrical power at the steam conditions set forth above in the amount specified on the guaranteed output line
This is the only performance guarantee made
May be verified by a performance test as prescribed by Skinner and conducted by the purchaser within 90 days of start-up, or it is deemed waived and the guarantee met
Any other performance data provided is predicted or estimated performance only and is not a guarantee or warranty
The above performance guarantee is subject to the conditions, limitations and remedies set forth in the limited warranty provision of Skinner’s standard conditions of equipment sale (February 2005)
Standard Turbine Scope
Turbine exhaust casing is axially split for ease of maintenance, as are the two separate bearing housings and packing boxes
Each turbine is standard fitted with independent mechanical overspeed trip mechanism, stainless steel steam strainer, carbon ring packing with stainless separators, sentinel warning valve, oil lubricated sleeve bearings, water cooled bearing housings, dynamically balanced rotor, standard commercial running test, high temperature paint, nameplate, and preparation for standard domestic shipment
Turbine materials are WCB cast steel for case, steam chest, nozzle stands, trip cage, and steam chest head
Blades are 410 stainless steel and shaft is 17-4 stainless steel
Speed Control Valve
Woodward 505 XT electronic governor for generator set applications, with pneumatically operated steam control flow valve to maintain correct speed of turbine
Gear
Single reduction parallel shaft speed reducer (Triveni), rated 1200 hp/894 kW with a 1.5 GMA SF minimum
Turbine speed of 5000 rpm reduced to a synchronous generator speed of 1500 rpm
Unit is equipped with babbitt bearings on high speed shaft and antifriction roller bearings on low speed shaft
Lubrication System
Integral lubrication system - a combined oil supply system designed to provide proper flow and temperature to gear mesh, gear bearings, and turbine bearings
Includes reservoir and/or gear sump, filter, air cooled heat exchanger, oil pump driven by low speed gear shaft, full capacity auxiliary electric oil pump, local gauges, oil pressure switch, and oil temperature switch
Lube system controls mounted in NEMA enclosure
Other Items Included
Base - “I” beam construction with turbine, gearbox and generator mounted and rough aligned; final alignment to be completed after installation of turbine on mounting pad and with all steam piping installed
Coupling - high speed and low speed couplings with guards, gear type, with spacer
Jackbolts - horizontal jackbolts for ease of alignment
Solenoid trip - activate
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.