Kawasaki, PU4000B-ER, 2008, Gas Turbine Power Plant, 51.2MW, 60Hz, 16 x 3.2MW

Description

  1. Overview
    1. Kawasaki PU4000B-ER gas turbine power plant
    2. 51.2 MW at 60 Hz
    3. 16 units of 3.2 MW each
  2. Gas Turbine Specifications
    1. Brand: Kawasaki
    2. Model: M1T-23
    3. Quantity: 16 sets
    4. Year of production: 2008
    5. Power output: 3,457 kW
    6. Turbine speed: 22,000 rpm
    7. Reduction gear speed: 1,800 rpm
    8. Fuel oil: natural gas (start/stop by kerosene oil)
    9. Fuel consumption: natural gas 1,270 Nm³/h + 5% tolerance (LHV: 40,605 kJ/m³h)
  3. Generator Specifications
    1. Brand: Meiden
    2. Model: E-AF
    3. Quantity: 16 sets
    4. Year of production: 2008
    5. Power output: 3,200 kW
    6. Frequency: 60 Hz
    7. Voltage: 6,600 V
    8. Rated current: 350 A
    9. Phase: 3Φ
    10. Power factor: 0.8
  4. List of Equipment
    1. Gas turbine (enclosure)
    2. Generator (enclosure)
    3. Reducer gear (enclosure)
    4. Fuel cooler
    5. Primary exhaust silencer
    6. Secondary exhaust silencer
    7. Primary engine intake silencer
    8. Secondary engine intake silencer
    9. Pressure adjust damper
    10. Ventilation damper
    11. Engine intake salt damage filter
    12. Engine intake expansion tube
    13. Ventilation fan
    14. Ventilation fan expansion tube
    15. ESV unit
    16. SSV unit
    17. Gas accumulator 3 m³
    18. Fuel small tank 5,000 L
    19. Liquid level switch – upper/lower limit alarm and trip pump start/stop
    20. Tank room damper 280x2, 300x2
    21. Tank room ventilation fan
    22. Fuel tank 50,000 L
    23. Fuel supply box-1 (liquid level meter included)
    24. Liquid level transmitter (fuel tank)
    25. Oil leak detector (fuel tank)
    26. Oil pump (fuel tank)
    27. Air compressor 1.5 kW
    28. Air tank 400 L
    29. Air dryer (refrigeration type)
    30. Air filter
    31. Pressure switch
    32. Liquid fuel temperature detection
    33. Spare parts and tools
    34. Electric panels
  5. Plant History and Information
    1. Application: for emergency standby
    2. Total running hours: about 60 hours for each set
    3. Plant layout: 16 sets installed by 4 blocks x 4 sets
    4. Pre-running: regularly operated to be ready for emergency use 2-3 times a month
    5. Status: ready to delivery