Wartsila, 32, Generating Set, 5.6 to 9.8 MWe, 50Hz/60Hz, 720/750 RPM

Description

  1. Main Benefits
    1. Low operating cost.
    2. Compact sizing enables transportation to demanding locations.
    3. Proven in service for decades.
    4. Operates on liquid biofuels, crude oil, light fuel oil and heavy fuel oil.
    5. Optimised performance and efficiency supported by Wartsila lifecycle solutions.
  2. Key Figures
    1. 2 minutes to full load.
    2. 47.6% electrical efficiency.
    3. Over 60 million running hours.
  3. Technical Data (5% Tolerance Without Pumps, 50 Hz / 60 Hz)
    1. Output (MWe): 5.6 to 9.8.
    2. Engine speed (rpm): 750 / 720.
    3. Electrical efficiency (%): HFO: 47.2 / 47.4; LFO: 47.4 / 47.6.
    4. Heat rate: HFO: 7,622 / 7,592; LFO: 7,599 / 7,563.
    5. Bore / stroke (mm): 320 / 400 mm.
    6. BMEP (bar): 24.9 - 28.9.
    7. Piston speed (m/s): 9.6 / 10.0.
    8. Cylinder configurations: 12V, 16V, 20V.
    9. NOx optimisation (ppm) (@ 15% O2, dry): 710 (LFO) and <900 (HFO).
  4. Technical Data (0% Tolerance With Engine Driven Pumps, 50 Hz / 60 Hz)
    1. Output (MWe): 5.6 to 9.8.
    2. Engine speed (rpm): 750 / 720.
    3. Electrical efficiency (%): HFO: 44.5 / 44.6; LFO: 44.6 / 44.8.
    4. Heat rate: HFO: 8,097 / 8,066; LFO: 8,073 / 8,035.
    5. Bore / stroke (mm): 320 / 400 mm.
    6. BMEP (bar): 24.9 - 28.9.
    7. Piston speed (m/s): 9.6 / 10.0.
    8. Cylinder configurations: 12V, 16V, 20V.
    9. NOx optimisation (ppm) (@ 15% O2, dry): 710 (LFO) and <900 (HFO).
  5. Performance Notes
    1. Rated electrical power, heat rate and electrical efficiency are given at generator terminals at 100 kPa ambient pressure, 25°C suction air temperature and 30% relative humidity.
    2. Power factor 1.0 (site).
    3. Fuel consumption with 5% and 0% tolerance according to ISO 3046-1.
    4. Site conditions, fuel and applicable emission limits have an impact on performance figures.
    5. Please contact Wartsila for project-specific performance data.
    6. Catalyst systems are designed based on project specific requirements.
    7. Certain fuel components are poisonous for catalyst elements; maximum amount of these components to be limited in the fuel in applications where catalyst system is installed.
  6. Loading Capabilities
    1. Start-up command.
    2. Speed acceleration within 20 s.
    3. Synchronization within 10 s.
    4. Generator breaker close command; initial load 10%.
    5. Loading at rate of 1%/s.
    6. Full load reached within 120 s.
  7. Loading Capabilities (Alternate)
    1. Start-up command.
    2. Start-up preparations: activation of prelubrications, slow turning.
    3. Speed acceleration.
    4. Synchronization.
    5. Generator breaker close command; initial load 10%.
    6. Loading at rate of 0.5%/s.
    7. Full load reached within 5 min.
  8. Maximum Transportation Dimensions (mm) and Weights (tons)
    1. 12V32: length 10,226 mm, width 3,000 mm, height 4,104 mm, dry weight 92 tons.
    2. 16V32: length 11,189 mm, width 3,300 mm, height 4,483 mm, dry weight 117 tons.
    3. 20V32: length 13,142 mm, width 3,300 mm, height 4,342 mm, dry weight 130 tons.
  9. Summary
    1. Operates on liquid biofuels, crude oil, light fuel oil and heavy fuel oil.
    2. Provides high efficiency throughout the entire life of the power plant.
    3. Compact sizing enables transportation to demanding locations.
    1. USA.