General Electric, 7E.03, 2014, 86.5 MW, Natural Gas Generator Package

Description

  1. Overview
    1. Housed: yes, in an ambient controlled warehouse in two locations
    2. What doesn’t have to be indoors is outside on an enclosed field, 2.5 hours away from the warehouses
    3. Skidded: no
    4. Connection status: disconnected
    5. Warranty: no
    6. Warranty details: exp dec 2018
  2. Condition
    1. Pasc condition rating: a
    2. Condition details: never used
    3. Hours: factory test fire only, i.e. new
    4. Stored in accordance with ge’s storage/preservation requirements
    5. Unit has not been rotated - not required on 3 bearing units
    6. Borescope on gtg and quarterly electrical insulation resistance check on the generator
  3. Generator Information
    1. Generator make: ge (general electric)
    2. Generator model: 7a6
    3. Generator serial #: 436x273
    4. Electric capacity: 86.5 mw
    5. Hertz: 60 hz
    6. Generator: ge/andritz
    7. Frame: bdax (brushless)
    8. Excitation: ge ex2100
    9. Frequency/power factor: 60 hz/0.85 pf
    10. Rated output: 101.8 mva
    11. Cooling: air-cooled
    12. Terminal voltage: 13.8 kv (2 pole, 3-phase, wye conn.)
  4. Driver Information
    1. Driver types: natural gas
    2. Driver make: ge (general electric)
    3. Driver model: 7e.03
    4. Max hp: 122,000 hp
    5. Rated rpm: 3600 rpm
  5. Package Description
    1. The package comprises the following major components along with all ge scope of supply and auxiliaries
    2. Frame 7ea gas turbine model pg7001ea (7e.03)
    3. Dry low nox (for dln 1.0 combustion system*)
    4. Natural gas single fuel supply
    5. Design site output/heat rate 84.6 mw at 1916 ft and 32°f; 91 mw at 0 ft and 32°f
    6. Includes ge pip package (minus stg 3 aero), 2055°f firing temp
    7. Inlet/exhaust: pressure drop: 3.5/5.5 inches of h2o
    8. Control system: mkvie speedtronic tmr
    9. Designed for the canadian market
  6. Included Auxiliary Equipment
    1. Air cooled glycol heat exchangers c/w vfd’s, filters, glycol pumps, gsu transformer
    2. Glycol expansion vessel
    3. 52g synchronizing breaker compartment included @ 13.8 kv incl. all protection relays etc.
    4. Heat recovery steam generator (hrsg - not complete)
  7. Missing Combustion Components
    1. Combustion system (for gtg) not included or installed - combustor components from refurbished parts are available upon request at additional cost
    2. Primary fuel nozzles
    3. Secondary fuel nozzles
    4. Flow sleeves
    5. Liners
    6. Cross fire tubes
    7. Transition pieces and tp seals
    8. All gaskets, nuts, bolts, screws, pins to install the above
    1. Building heated: no
    2. Availability status: available