Siemens, SGT-400, 2016, Gas Turbine Generator Unit, 50 Hz, 2955 Hours

Description

  1. Overview
    1. Factory built in 2016 and commissioned in 2018.
    2. Total of 2,955 hours of operation and 80 start-ups.
    3. Shut down in 2020 due to increased natural gas prices and reduced steam consumption from surrounding customers, resulting in operating losses.
    4. Unit has not undergone first maintenance; no maintenance record available.
  2. Specifications
    1. Model: Siemens SGT-400.
    2. Fuel: Natural gas.
    3. Additional fuel variant: Biogas version.
  3. Condition
    1. Only 2,955 hours of operation.
    2. Endoscopic inspection of turbine blades: Leaves retain original color; no ablation or coating discoloration found.
    3. Stains present on some blades; engine requires cleaning.
    4. Coating on some blades suspected to have been hit and fallen off by impurities; air intake quality needs improvement.
  4. Included Items
    1. Item 001: Unit with 2,955 hours of operation, natural gas version.
    2. Item 002: Biogas version.