Mitsubishi, Fuji, Hyundai Combined Power Plant, 2000, 378 MW, 3000 RPM

Description

  1. Overview
    1. Gas turbine and steam turbine combined cycle
    2. Item 001: Mitsubishi M701F gas turbine
    3. Item 002: Fuji steam turbine
    4. Item 003: Hyundai HRSG
  2. Gas Turbine Specifications
    1. Rated capacity: 247 MW
    2. Maximum capacity: 275 MW
    3. Rated speed: 3000 rpm
    4. Relative humidity: 80%
    5. Year: 2000
  3. Steam Turbine Specifications
    1. Rated capacity: 131 MW
    2. Rated speed: 3000 rpm
    3. Main steam pressure: 100 bara
    4. Main steam temperature: 565 °C
    5. Type: Reaction reheat condensing
    6. Casing: Two casing double flow exhaust
    7. Year: 2000
  4. HRSG Specifications
    1. Power is reduced to 360 MW
  5. Specifications
    1. Capacity: 378 MW