MAN, 18V32/40, 9.0 MW, 50/60 Hz, Diesel/HFO Generator Set

Description

  1. Overview
    1. Diesel/HFO 18V32/40 basic MAN
    2. Gross electrical output approx. 9.0 MW
    3. Using gas is possible against cost note for conversion
    4. The gross electrical output of this plant is approximately 9 MW each specified at the generator terminals
    5. Other compilations are of course possible
  2. Performances
    1. Preliminary performance data
    2. Gross electrical power: 213 kWe
    3. Specified at the generator terminals
    4. Gross heatrate: 7,832 kJ/kWh
    5. Specified at the generator terminals
    6. Given at +25°C (77°F)
    7. 30% RH and 100masl ambient conditions with ±0% tolerance
    8. 11kV generator voltage
    9. Gas methane number >80
    10. LHV >30MJ/Nm³
    11. Gas pressure min 5 bar(g)
    12. Power factor 0.8 refer to Exhibit D for detailed performance figures
    13. Kindly note that we provide performance figures
    14. With 0% tolerance
  3. Scope Typically Including
    1. Basic engineering of the plant
    2. Detailed design of all MAN supplied equipment
    3. Generating sets & automation/control system
    4. Auxiliary equipment needed for the power generation
    5. Medium voltage & low voltage switchgears
    6. Technical advisors for assistance during installation
    7. Technical advisors for assistance during commission
    8. Training on site
  4. Scope Typically Excluding
    1. All civil material & work
    2. Installation and supervision
    3. All site management and site offices
    4. Piping material, cables & tanks
    5. Exhaust gas emission cleaning equipment (if required)
    6. Switchyard and stepup transformers
    7. Any other work or services not mentioned here
    8. Plant operating manuals
  5. 9 MW Generator Set
    1. Brand: MAN Diesel & Turbo, type 18V32/40 — 4 stroke, unused
    2. Each unit consists of motor, generator, rack / base-frame
  6. Motor
    1. Speed: 750 rpm
    2. Power at crankshaft: 9,000 kWm
    3. Emission: WB 1998
  7. Power-To-Weight Ratio (MCR)
    1. In-line engine: 11.3 to 12.7 kg/kW
    2. V-engine: 9.4 to 10.2 kg/kW
  8. Cylinder Output (MCR)
    1. At 750/720*) rpm: 500 kW (670.5 hp)
  9. Cooling
    1. Cylinder cooling: fresh water
    2. Charge-air cooler (two-stage): fresh water
    3. Fuel injector cooling: fresh water, only when running on
    4. HFO
    5. Starting method: compressed air
    6. Generator: 50 Hz or 60 Hz
    7. Voltage: 11kV
    8. Output approx.: 10,940 kVA
    9. Alternator efficiency: 97.24%
  10. Generator-Unit
    1. Continuous power output: 8,752 kWel
    2. Specific fuel consumption at 100% load: 190.35 g/kWel
    3. Lube oil consumption (+ 20% tolerance): 4.5 kg/h
    4. Weight per unit: 151 ton
    5. Parameters according to: ISO condition
  11. Generator ZU MAN 18V32-40 Diesel Generator Sets
    1. Brand: ABB
    2. Type: AMGI 120LT08DSE
    3. Phases: 3
    4. Duty: S1
    5. Connection: Y
    6. Insul cl.: F (temp. cl. F.)
    7. Weight: 34,000 kg (74,957 lb)
    8. Protection class: IP 23
    9. IC: 0A1
    10. M: 1101
    11. Output: 10,947 kVA
    12. Voltage: 11,000 volts
    13. Frequency: 50 Hz
    14. Speed: < 750 (nR 900) rpm
    15. Current: 575 A
    16. Power factor: 0.8
    17. Ambient: +43 °C (109°F)
    18. Excit: 58 VDC 8.0 ADC