Siemens, SST-300, 2021, 21MW, 11,000 Volts, 50Hz, Steam Turbine Generator

Description

  1. Overview

    1. New (never installed) 2021 Siemens SST-300 complete steam power generator

    2. Unpacked, still boxed and crated, complete plant

    3. This offer includes state-of-the-art equipment, all new and securely packaged

  2. Product Details

    1. Model: Siemens SST-300

    2. Year of manufacture: 2021

    3. Condition: new, unpacked, still boxed and crated

  3. Technical Specifications

    1. Rated/max output: 20.29 MW

    2. Speed: 5,314 RPM

    3. Voltage: 11,000 volts

    4. Frequency: 50 Hz

    5. Inlet steam: 37 barg, 376 °C, 72.5 t/h

    6. Admission steam: 18.9 barg, 348.8 °C, 65.6 t/h

    7. Steam extraction: 3.5 barg, 155 °C, 53.64 t/h

    8. Exhaust steam: 0.093 bara, 44 °C

    9. Skid dimensions (turbine and gearbox): 7,610 mm x 6,300 mm

    10. Skid weight: 65,500 kg

    11. Dimensions with generator and condenser: 23,350 mm x 10,335 mm

  4. Condition and Notes

    1. This turbine is a condensing steam turbine with a generator package

    2. Although still new and unpacked, the warranty is no longer valid and is sold as is

    3. Siemens has been contacted and they are prepared to do a full pre-inspection and re-validate the warranty at the buyer's cost

  5. Standard Information on Siemens SST-300 Industrial Steam Turbines

    1. Power output: up to 45,000 kW (61,182.95 hp)

    2. Speed: 12,000 RPM

    3. Inlet pressure: up to 140 bar (2,030 psi)

    4. Inlet temperature: up to 540 °C (1,004 °F)

    5. Exhaust steam parameters: back pressure up to 16 bar (232 psi), condensing up to 0.3 bar (4.4 psi), district heating up to 3.0 bar (43 psi)

    6. Controlled extractions: up to 2, with pressure up to 25 bar (362 psi) and temperature up to 400 °C (752 °F)

    7. Uncontrolled extractions: up to 6, with pressure up to 60 bar (870 psi)

    8. The SST-300 is known for its compact design and simple layout, which significantly reduce the cost and time associated with construction, inspection, and maintenance

    9. It can be configured with either an upward, downward, or axial exhaust orientation depending on the layout of the plant