Foster Wheeler, AG-5050, 2002, D-Type Water Tube Boiler, 75,000 lb/hr, 280 psig, Natural Gas & #2 Oil

Description

  1. Overview
    1. Manufacturer: Foster Wheeler
    2. Model: AG-5050
    3. Type: D-type water tube steam boiler
    4. Year: 2002
    5. Condition: Used
  2. Performance
    1. Steam capacity: 75,000 lb/hr (75 kpph)
    2. Maximum continuous rating (MCR): 75,000 lb/hr
    3. Working pressure: 280 PSIG
    4. Efficiency: 83.6% (HHV)
    5. Steam purity: 99.5%
    6. NOx emissions: 30 ppm
  3. Pressure Parts and Heating Surfaces
    1. Boiler: MAWP 280 PSIG, heating surface 3,454 sq ft
    2. Waterwall: MAWP 280 PSIG, heating surface 689 sq ft
    3. Economizer: MAWP 400 PSIG, heating surface 7,179 sq ft
    4. Maximum design steam capacity: 75,000 lb/hr
    5. Code: ASME "S" stamp, National Board registered
    6. Hydrostatic tests to be conducted at a minimum metal temperature of 70°F (21.1°C)
  4. Construction
    1. 100% membrane wall
    2. 54" diameter steam drum
    3. Refractory in burner front wall
  5. Fuel and Burner
    1. Fuel: natural gas and #2 oil
    2. Front-wall burner with oil burner nozzle gun
  6. Scope of Supply
    1. D-type water tube boiler
    2. Forced draft fan and motor
    3. Feedwater economizer
    4. Feedwater economizer support structure
    5. Exhaust stack