Description What’s Inside GE LM2500 gas turbine 2,000+ engines worldwide More than 97M operating hrs Recognized as the industry leader in its size class Brush electrical generator Air-cooled generator with brushless excitation Suitable for class 1, group D, div. 2 areas Rated at 32,550 kVA @ 0.90 PF, 59 deg. F cooling air, 13.8 kV, 60 Hz (11.5 kV @ 50 Hz) General Arrangement Proven 4-trailer system Minimal foundation requirements and prep Quick set-up Site Preparation and Foundation Level within 6 inches per 100 feet Solid crushed gravel with 1” steel plates Adequate access and space, well-lit, secure Electrical Connections Generator output 13.8 kV @ 60 Hz (11.5 kV @ 50 Hz) Auxiliary power requirement 480V, to motor control center main circuit breaker (250 kW) Grounding Customer furnished grounding system GE provides ground grid specification and interconnection requirements Customer Interface Details Fuel: gas supply pressure is 395 (+/- 20) psig at a rate of 12,000 pph (250 MMBtu/hr or 6 Mscf/day) Fuel: gas consumption for 50 Hz / 22 MW is at 198 Mcf/hr Fuel: liquid fuel (diesel) supply pressure is 30 (+/- 10) psig, up to 40 gpm (max) Water (for NOx suppression): minimum supply pressure is 15 psig up to 28 gpm (max) Inlet/exhaust air: nominal inlet air flow 150,000 cfm (120,000 turbine / 30,000 enclosure ventilation) Inlet/exhaust air: exhaust stack height is 20’ when fully assembled Inlet/exhaust air: flange dimensions 96” x 96” Inlet/exhaust air: exhaust gas flow 490,000-550,000 lbs/hr Emissions: liquid fuel – 42 ppm NOx with water injection Emissions: gas fuel – 25 ppm NOx with water injection Noise: approximately 88 dBA Waste: lubricating oils (turbine and generator) Waste: turbine wash detergent and rinse water