Search results for: 'Pro'
- Related search terms
- Prod
- Produ
- pro',(;))#- --
- product
- pro 4 pro
-
T-6551 MASK FLAME RETARDANT PERFORMANCE TESTERREFERENCE NUMBER: T-6551
MASK FLAME RETARDANT PERFORMANCE TESTER
MASK FLAME RETARDANT PERFORMANCE TESTER
TECHNICAL INDEX:
1.THE LINEAR VELOCITY OF THE NOSE TIP OF THE DIE IS (60 ± 5) MM / S
2.THE DIAMETER OF FLAME TEMPERATURE MEASURINGPROBE IS 1.5MM
3.THE FLAME TEMPERATURE IS (800 ± 50) °C
4.THE DISTANCE BETWEEN THE BURNER TOP AND THE MASK IS (20 ± 2) MM
5.METAL DIE
APPLICABLE STANDARD:
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
YY 0469-2011 MEDICAL SURGICAL MASK
MEDICAL PROTECTIVE MASK REFERS TO A SELF-PRIMING FILTER TYPE DUST-PROOF MEDICAL PROTECTIVE MASK THAT CAN FILTER THE PARTICLES IN THE AIR AND BLOCK THE DROPLETS, BLOOD, BODY FLUIDS, SECRETIONS, ETC.
QUANTITY: 1
Learn More -
T-6552 MASK AIR TIGHTNESS TESTERREFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
Learn MoreMASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 -
T-6592 INFRARED THERMOMETERREFERENCE NUMBER: T-6592
INFRARED THERMOMETER
INFRARED THERMOMETER
DATA FOMART RESOLUTION 0.1°C(0.1°C)
AMBIENT TEMPERATURE 10-40°C
STORAGE TEMPERATURE 0-50°C
RELATIVE HUMIDITY<80%
POWER SUPPLY DC9V(NOT INCLUDED)
PRODUCT SIZE 160X100X40mm
GROSS WEIGHT 125G WITHOUT BATTERY
RANGE OF TEMPERATURE
BODY TEMPERATURE MODE (32°C-42.5°C)
ACCTURACY ±0.3°C(0.45°F)
MEASUREMENT DISTANCE 50 TO 100mm
EVERY FAMILY NEEDS A THERMOMETER AND PAY ATTENTION FOR THE HEALTH OF YOUR FAMILY
LEAD TIME-SHIPPING TIME 5-7 DAYS BY FEDEX:MASS GOODS: 2-4 DAYS
ITEM 001
QUANTITY: 100
ITEM 002
QUANTITY: 500
LEAD TIME-SHIPPING TIME 5-7 DAYS BY FEDEX:MASS GOODS: 5-10 DAYS
ITEM 003
QUANTITY: 1,000
ITEM 004
QUANTITY: 3,000
ITEM 005
QUANTITY: 5,000
Learn More -
T-6591 DISPOSABLE FACE MASKREFERENCE NUMBER: T-6591
DISPOSABLE FACE MASK
MATERIAL:NON-WOVEN WITH LAYERS FILTRATION SYSTEM
SIZE:L175X W95mm
COLOR:BLUE
MOISTURE-PROOF, BREATHABLE, NON-TOXIC,NON IRRITAING SOFT AND COMFORTABLE
FILTER EFFECT: PROTECTION LEVEL
PACKING: 20PCS/1 OPP BAG
VACUUM PACKING
CARTON SIZE: 520 X520 X720mm
8000PCS/CARTON
G.W: 28 KG
LEAD TIME-SHIPPING 5-7 DAYS BY EXPRESS: MASS GOODS 2-4 DAYS
ITEM 001
QUANTITY: 10,000
ITEM 002
QUANTITY: 50,000
ITEM 003
QUANTITY: 100,000
LEAD TIME-SHIPPING 5-7 DAYS BY EXPRESS: MASS GOODS 5-12 DAYS
ITEM 004
QUANTITY: 500,000
ITEM 005
QUANTITY: 1,000,000
Learn More -
T-6589 KN95 FACE MASKREFERENCE NUMBER: T-6589
KN95 FACE MASK
MATERIAL: 5LAYERS MATERIAL NOSE CLIP LINE, 3D FILTER AGAINST DROPLET
SIZE: 197X 136X 16mm
COLOR: WHITESAFE,BREATHABLE AND HYPOALLERGENIC;AND HIGH FILTRATION,CAPACITY.
PROVIDE SOME PROTECTION AGAINST DUST, OR SOME POISONOUS THINGS
PACKING:5PCS/OPP BAG CARTON SIZE: 700 X 500 X 500mm
2500PCS/CARTON
G.W: 15 KG
REMARK: ACCEPT CUSTOM LOGO
LEAD TIME -SHIPPINGTIME: 5-7 DAYS BY FEDEX, MASS GOODS: 2-4DAYS
ITEM 001
QUANTITY: 1,000
ITEM 002
QUANTITY: 5,000
ITEM 003
QUANTITY: 10,000
LEAD TIME -SHIPPINGTIME: 5-7 DAYS BY FEDEX, MASS GOODS: 5-7 DAYS
ITEM 004
QUANTITY: 50,000
ITEM 005
QUANTITY: 100,000
Learn More -
P-8696 ULTRASONIC SEWING MACHINELearn MoreREFERENCE NUMBER: P-8696
ULTRASONIC SEWING MACHINE
CAN BE USED WITH EITHER 20 KHz, 30 KHz OR 40 KHz EQUIPMENT
LED DISPLAY FOR EASY PROCESS MONITORING
19” (483mm) THROAT
INDEPENDENT CONTROLS FOR SLITTING AND ROTARY ANVIL WELDING
DUAL SEALING CAPABILITIES WITH INDEPENDENT ADJUSTMENTS
EDGE GUIDING, REWINDING, AND FEED ROLLS CAN BE USED
CAN BE OPERATOR CONTROLLED AS A BENCHTOP UNIT OR INTEGRATED INTO AN EXISTING LINE
QUANTITY: 1
-
JASON LIST-1472 FACE MASK TYPESJASON LIST# 1472
FACE MASK TYPES
REFERENCE NUMBER: MASK-1111
FLAT, SURGICAL MASK, 3-PLY NONWOVEN SPUNBOND, MELTBLOWN AND SPUNBONDREFERENCE NUMBER: MASK-1112
REFERENCE NUMBER: MASK-1113
REFERENCE NUMBER: MASK-1121
SEE J-2756 FOR THE LINE THAT PRODUCES THESEREFERENCE NUMBER: MASK-1115
KN95 MEDICAL MASKS (PARTICULATE RESPIRATORS)REFERENCE NUMBER: MASK-1116
N95 MEDICAL MASKS (PARTICULATE RESPIRATORS)REFERENCE NUMBER: MASK-1117
FFP2 MEDICAL MASKS (PARTICULATE RESPIRATORS)REFERENCE NUMBER: MASK-1118
3M MODEL 1860 MEDICAL MASKS (PARTICULATE RESPIRATORS)REFERENCE NUMBER: MASK-1119
3M 8577 MEDICAL MASKS (PARTICULATE RESPIRATORS)REFERENCE NUMBER: MASK-1120
3M 9541V MEDICAL MASKS (PARTICULATE RESPIRATORS)REFERENCE NUMBER: MASK-1124
3M 1870 HEALTH CARE PARTICULATE RESPIRATOR & SURGICAL MASKREFERENCE NUMBER: MASK-1122
3M 1860S HEALTH CARE PARTICULATE RESPIRATOR & SURGICAL MASKREFERENCE NUMBER: MASK-1123
3M 1860 HEALTH CARE PARTICULATE RESPIRATOR & SURGICAL MASKMore information is available upon request.
Learn More
E-mail us for price, pictures, video, or diagram.
Include our reference number. -
J-2813 HANDHELD AIRBORNE PARTICLE COUNTER, MODEL 3000FEATURES
0.3 - 25 µm SENSITIVITY
FLOW RATE: 1.0 CFM (28.3 LPM)
UP TO 8 CHANNELS OF SIMULTANEOUS COUNT DATA
21 CFR PART 11 COMPLIANT SECURE USB FLASH TRANSFER
EXTREME LIFE LASER DIODE TECHNOLOGY >20-YEAR MTTF
5.7 INCH COLOR TOUCH SCREEN DISPLAY
THERMAL PRINTER
STAINLESS STEEL CONSTRUCTION
ETHERNET/RS485/MODBUS, 4x 4-20mA ANALOG INPUTS
3,000 RECORD DATA STORAGE
50-RECORD CONFIGURABLE RECIPE DATABASE
REPORT WIZARD: FS-209E, ISO-14644-1 & EU GMP ANNEX 1
2 YEAR WARRANTYSTANDARD 6 CHANNELS: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm , 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 µm
STANDARD 8 CHANNELS: 0.3,0.5,0.7,1.0,3.0,5.0,7.0,10.0 µm
OPTIONAL 8 CHANNELS: OPTIONAL BETWEEN 0.3 AND 25.0 µm
COUNTING EFFICIENCY: 50%@0.3µm; 100% FOR PARTICLES > 0.45 µm (PER ISO 21501-4)
CONCETRATION LIMITS: 1,000,000 PARTICLES/FT3, (35,300,000/M3) @ 10% COINCIDENCE LOSS SUITABLE FOR ISO CLASSES 1-8 CLEANROOMS
DIMENSIONS: 9.5”(L) x 8.0”(W) x 10.2”(H) (24.13 x 20.32 x 25.9 cm)
WEIGHT: WITH BATTERY: 13.95 LBS (6.33 KG), WITHOUT BATTERY 12.35 LBS (5.6 KG)INCLUDES
OPERATING MANUAL WITH CD, LMS EXPRESS TRANSFER SOFTWARE DOWNLOAD INSTRUCTIONS, ISOKINETIC SAMPLE PROBE, TRIPOD, TUBING, PURGE FILTER, POWER CABLES, SPARE FUSE, PRINTER, PRINTER PAPERLEAD TIME: 1 TO 2 WEEKS FROM RECEIPT OF ORDER
QUANTITY: 1
Learn More -
J-2811 AIRBORNE PARTICLE COUNTERAIRBORNE PARTICLE COUNTER
PORTABLE PARTICLE COUNTER WITH 0.10 MICRON SENSITITIVITY AND 1.0 CFM (28.3 LPM) FLOW RATE USING LONG LIFE LASER DIODE TECHNOLOGY.
DESIGNED TO OPERATE IN ISO CLASS 1 TO CLASS 7 CLEANROOMS WITHOUT CONCERNS OF IT DEGRADING ITS ENVIRONMENT OR EXCEEDING CONCENTRATION LIMITS
USES AN OPTICS AND PHOTODIODE SYSTEM DESIGNED TO REDUCE OR ELIMINATE THE TEMPERATURE ISSUES ASSOCIATED WITH HIGH POWER LASER DIODE SENSORS
WITH THERMALLY CONTROLLED EXHAUST SYSTEM AND HEPA FILTER OPTION TO PREVENT ANY EXTERNAL CONTAMINATIONFEATURES
0.1- 1.0 µm SENSITIVITY
1.0 CFM (28.3 LPM)
UP TO 8 CHANNELS OF SIMULTANEOUS COUNT DATA
21 CFR PART 11 COMPLIANT SECURE USB FLASH TRANSFER
LASER DIODE SENSOR TECHNOLOGY
5.7 INCH COLOR TOUCH SCREEN DISPLAY
THERMAL PRINTER
STAINLESS STEEL CONSTRUCTION
ETHERNET/RS485/MODBUS, 4X 4-20MA ANALOG OUTPUTS
3,000 RECORD DATA STORAGE
50-RECORD CONFIGURABLE RECIPE DATABASE
Report wizard: ISO-14644-1, EU GMP Annex 1, FS-209ESTANDARD CHANNEL SIZES: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0 µm
INCLUDES
OPERATING MANUAL ON CD; ISOKINETIC SAMPLE PROBE WITH TRIPOD AND TUBING; PURGE FILTER; POWER CABLE AND SPARE FUSE; LMS XCHANGE AND EXPRESS SOFTWARE; PRINTER; PRINTER PAPERQUANTITY: 1
Learn More -
V-1827 ATTENDANCE AND TEMPERATURE MEASUREMENTRECOGNIZES PEOPLE’S FACES WITH AND WITHOUT A MASK
Learn More
RECOGNIZES FACES 4 TO 5 METERS AWAY
MEASURES BODY TEMPERATURE
STORES 3,000 FACE PROFILES
CAN TRIGGER AN ALARM AND/OR NOT OPEN ENTRY DOOR IF SOMEONE HAS A FEVER.
EASY TO SET UP: ON A WALL, ON A TABLE, MOUNTED ON A STAND.