Search results for: 'air+pr'
- Related search terms
- air+pressure
- air+press
-
K-8416 G1 TONELLO 330 "CENTRIFUGING" INDUSTRIAL WASHING MACHINE-USEDREFERENCE NUMBER: K-8416
G1 TONELLO 330 "CENTRIFUGING" INDUSTRIAL WASHING MACHINE-USED
G1 TONELLO 330
“CENTRIFUGING” INDUSTRIAL WASHING MACHINE
FRONTAL TYPE
FOR CHEMICAL “STONE WASH”
CAPACITY LIT. 3.300
MOD. TONELLO G1 330
GENERAL DESCRIPTION:
TONELLO G1 IS A MACHINE WITH HIGH-SPEED HYDRO-EXTRACTION (600 R.P.M.) AND IT IS EQUIPPED WITH AUTOMATIC SELF-BALANCING SYSTEM
TONELLO G1 IS SUPPLIED WITH “SETTABLE INVERTER”
ROTATION SPEED FROM 0 TO 55 R.P.M
ALSO SETTING THE CENTRIFUGING SPEED FROM 0 TO 600 R.P.M.
WITH TIME OF CENTRIFUGE PROGRAMMABLE BY INDUSTRIAL PC
THE ACCESS MAIN DOOR TO THE DRUM IS VERY WIDE, IN ORDER TO EASY GARMENTS LOADING AND UNLOADING OPERATION
OPENING AND CLOSING ARE PNEUMATIC
DOUBLE TILTING SYSTEM FOR GARMENTS LOADING AND UNLOADING
DRIVING SYSTEM IS SITUATED ON THE UPPER PART OF THE MACHINE
WITH PROPER MATERIAL AND MOTORS SUITABLE TO WORK AT LOW AND HIGH R.P.M.
1 TANK FOR THE PREPARATION OF AUXILIARY PRODUCTS WITH CAPACITY OF LITTERS 180 EQUIPPED WITH ELECTRO-PUMP AND PNEUMATIC VALVES FOR THE SENT ONE
THE DRAINAGE IN DRAIN AND AUTOMATIC RINSES N° 2 WATER INLETS COMPLETE WITH PNEUMATIC VALVE- MECHANICAL WATER-COUNTER DIRECT HEATING AND COOLING SYSTEM
AUTOMATION WITH MICROPROCESSOR
TECHNICAL DATA TONELLO G1 330
DRUM DIMESION
-DRUM HOLING SHEET mm 4
THICKNESS
-DIAMETER MM 1900
-DEPTH MM 1150
-VOLUME LT. 3300
-DOOR DIAMETER MM 1020
-MAXIMUM LOADING KG. 120/130
CAPACITY
BASKET SPIN SPEED RPM 0-600
DIRECT STEAM CONNECTION Ø 1" 1/4
WATER INLET CONNECTION Ø 2 x 2
COMPRESSED AIR INLET Ø 1/4"
CONNECTION
STEAM IN MAXIMUM PRESSUREBAR BAR 6
WATER IN MAXIMUM PRESSURE BAR 4
COMPRESSED AIR IN MAXIMUM BAR 8
PRESSURE
POWER INSTALLED KW 22
3-PHASE VOLTAGE VOLT/HZ 400/50
PRODUCTS TANK Ø 240 H 400 LT. 80
TANK RINSING VALVE Ø 1/2"
MACHINE SIZE
-WIDTH MM 2500
-WIDTH WITH ELECTRICAL PANEL MM 2980
-DEPTH MM 2710
-HEIGHT MM 3000
Learn More -
T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More -
T-1138 LORIS BELLINI APPC/LV 150 HANKS CABINET DYEING MACHINE, YEAR 1988 RECONDITIONED 2016REFERENCE NUMBER: T-1138
LORIS BELLINI APPC/LV 150 HANKS CABINET DYEING MACHINE, YEAR 1988 RECONDITIONED 2016
HANKS CABINET DYEING MACHINE
UNDER PRESSURE TEMPERATURE 110°C
WITH EXTRACTABLES BASKETS
MODEL LORIS BELLINI APPC/LV 150
YEAR 1988 FULLY RECONDITIONED 2016
QUANTITY: 1
Learn More -
M-5012 TMT PF-1593 MULTIPROGRAM AUTOCLAVE DECATIZING MACHINE YEAR 1998REFERENCE NUMBER: M-5012 (1212YBZTXX11) L TMT PF-1593 MULTIPROGRAM AUTOCLAVE DECATIZING MACHINE YEAR 1998 AUTOCLAVE DECATIZING MACHINE MANUFACTURER: TMT MODEL: PF 1593 MULTIPROGRAM YEAR OF CONSTRUCTION: 1998 AUTOCLAVE DIAMETER: 1500mm SATIN CLOTH WIDTH: 1800mm SATIN CLOTH LENGTH STANDARD: 750 TO 1,000 MT. MAXIMUM FABRIC WIDTH: 1600mm POWER INSTALLED: 48 KW POWER USED: 30 KW STEAM PRESSURE: 6 TO 11 BAR COMPRESSED AIR PRESSURE: 6 TO 8 BAR MACHINE IS IN EXCELLENT CONDITION AND IS RUNNING AVAILABLE END OF DECEMBER 2014 QUANTITY AVAILABLE: 1 Learn More -
M-4061 DUSENBERY MODEL 835 DUPLEX CENTER SLITTER YEAR 1997REFERENCE NUMBER: M-4061 (990985DC8U) L DUSENBERY MODEL 835 DUPLEX CENTER SLITTER YEAR 1997 DUSENBERY MODEL 835 WEB WIDTH OF 72” THE 835 IS DESIGNED TO RUN MATERIALS SUCH AS .0005 PVCD THOROUGH 25 MIL RIDGE FILMS AND PAPER. MANUFACTURED DATE OF 1997 QUANTITY: 1 Learn More -
DORNIER PTS4/S RAPIER LOOM SETUP TO WEAVE, WIDTH 1900mm, YEAR 2016REFERENCE NUMBER: T-6980 DORNIER PTS4/S RAPIER LOOM SETUP TO WEAVE, WIDTH 1900mm, YEAR 2016 DORNIER PTS4/S RAPIER LOOM SETUP TO WEAVE WIDTH 1900mm FLAT CARBON FIBER YARN YEAR 2016 (INCORPORATING ISUMI WEFT FEEDER AND TEXKIMP COMPOSITE 960 END CREEL) BRIEF TECHNICAL INFORMATION: MAKE AND TYPE: DORNIER PTS 4/S WEFT INSERTION: RAPIER RAPIER: FIXED / POSITIVE WEFT COLORS: 4 (ONLY 1 BEING USED) ECS SELECTORS: 4 WEFT FEED: ISUMI NO TWIST SINGLE FLAT YARN FEEDER MODEL WF-510 WARP FEED: 960 END TEXKIMP COMPOSITE CREEL TYPE CF-F SELVEDGE TYPE: CATCH SELVEDGE CUTTER LHS AND RHS PREINSTALLED SELVEDGE WASTE BIN: 1 DOBBY MODEL & TYPE: STAUBLI S3020 E3 INSTALLED LEVERS: 12 INSTALLED UNDERMOTIONS: 12 FRAMES SUPPLIED: 12 LOOM TAKE-UP: ELECTRICAL LOOM LET-OFF: ELECTRICAL CLOTH ROLLERS: 2 X AIR BARS FOR WINDING ONTO CARDBOARD TUBE HEALD WIRES: AS ON LOOMS CONTROL PANEL: 15 INCHES TOUCHSCREEN PANEL ERGOWEAVE SPARE PARTS & MANUALS: ALL RELATED SPARE PARTS AVAILABLE IN THE FACTORY ELECTRICAL SUPPLY: 3 PHASE 380-415V, 50Hz QUANTITY: 1 Learn More -
KARL MAYER FRACTIONAL WARPER AND KARL MAYER ROTAL SIZING MACHINE, YEAR 2002REFERENCE NUMBER: T-6925 KARL MAYER FRACTIONAL WARPER AND KARL MAYER ROTAL SIZING MACHINE, YEAR 2002 ITEM 001 KARL MAYER FRACTIONAL WARPER MOD ZM-SP 2000/1250DNC AIR PRESSURE 6 ATM YEAR OF CONSTRUCTION 2002 CREEL MODEL GWSP780 NUMBER POSITION BOBBIN 780 DISTANCE EACH POSITION 335mm DIAMETER BEAM 1250 WIDTH 2000 WORKED 2 SHIFT 5 DAYS A WEEK DUST ASPIRATION ON WARPING UNIT TYPE KM 711R44RD 90160L POWER 15 KW YEAR 2002 WARPING BEAM DIAMETER 1250 X 2000 WIDTH N24 ELECTRIC FORKLIFT ARMANNI FOR THE WARPING BEAM ELECTRIC CHARGER FOR FORKLIFT ITEM 002 KARL MAYER ROTAL SIZING MACHINE MOD ELC O TENS YEAR OF CONSTRUCTION 2002 WIDTH 4000mm MAX DIAMETER BEAM 1250 APPLICATION OF WAX OUTSIDE DRYING CILINDER WORKED 1 SHIFT 5 DAYS X WEEK 1-SIZING BOX, 2 SET OF 2 SQUEEZING CYLINDERS STEAM CILINDER 8 WITH TEFLON 2 STAINLESS STEEL TOT 10 DIAMETER 800 WIDTH 2000mm CREEL OF SIZING 16 BEAMS WIDTH 2000mm DIAMETER 1250 KITCHEN SIZING MODEL MPD-PW/2000 YEAR 2002 CRANE TYPE 414 CAP. UP TO 1600KG SIZING ASPIRATION ON DRYER STAINLESS STEEL 2 MOTOR ASPIRATION 11+7.5KW DUST ASPIRATION ON THE ROLLING SYSTEM SPECIAL FORKLIFT FOR FULL BEAM MAX WIDTH OF BEAM 4000mm MAX WEIGHT 2000KG YEAR 2012 Learn More -
T-6582 MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)REFERENCE NUMBER: T-6582
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
1.NP3030: MEDICAL DISPOSABLE PROTECTIVE CLOTHING,STRONG RESISTANT
2.FABRIC: SF 66 G, COLOR: WHITE RUBBER:CAP/FOOT/CUFF/WAIST FRONT FLAP: DOUBLE-SIDED TAPE, TAPE:BLUE TAPE, ETHYLENE OXIDE DISINFECTION, STERILE
3.PACKAGED: 1PC/BAG, 32PCS/CARTON,10KG/CARTONCARTON SIZE: 470 X300 X420mm/CTN
4.NOTE: CLASS II MEDICAL TREATMENT, SCOPE OF USE: MEDICALPERSONNEL CONTACT WITH POTENTIALLY INFECTIOUS PATIENTSBLOOD, BODY FLUIDS, SECRETIONS, PARTICLES IN THE AIR TOPROVIDE BARRIER, PROTECTION. THIS PRODUCT IS USED FORISOLATION OF OBSERVATION WARD (ROOM), ISOLATION WARD(ROOM), ETC. IT IS STRICTLY PROHIBITED TO USE IN THE ISOLATIONCRITICAL CARE WARD (ROOM) AND OTHER PLACES WITH STRICTCONTROL OF MICROBIAL INDICATORS1PC/BAG, 32PCS/CARTON.
WEIGHT AND DIMENSIONS OF CARTONS: 10KG/CARTON
CARTONS IN A 20 FOOT CONTAINER: 370 BOXESSTERILIZED BY ETHYLENE OXIDE GAS
EACH PIECE IS INDIVIDUALLY VACUUM PACKED
1PER PLASTIC POUCH
QUANTITY: 10,000
Learn More -
T-6586 ISOLATION PROTECTIVE CLOTHING MT-B001-XL, 70G COMPOSITE NON-WOVEN FABRICREFERENCE NUMBER: T-6586
ISOLATION PROTECTIVE CLOTHING MT-B001-XL, 70G COMPOSITE NON-WOVEN FABRIC
ISOLATION PROTECTIVE CLOTHING
MODEL: MT-B001-XL
MATERIAL: 70G COMPOSITE NON-WOVEN FABRIC
SURFACE: WITH BLUE SEALING STRIPS
WEIGHT: 230G/PIECE
SIZE: XL (170-180CM)
DESIGN: ONE-PIECE TYPE FRONT OPENING, COLLARLESS HOOD, ELASTIC BRIM, ELASTIC CUFFS AND LEG OPENINGS.
FEATURE: ISOLATE BACTERIA, WATERPROOF, MICRO BREATHABLE, TEXTURE SOFT, THE HIGHEST GRADE MEDICAL PROTECTIVE CLOTHING MATERIAL.
USAGE: USED FOR VIRUS PROTECTION IN HOSPITAL GENERAL SICKROOM, AIRPORT, BUS STATION, RAILWAY STATION, FACTORY ETC.
CERTIFICATE: CE
ITEM 001
QUANTITY: ≥ 30,000 PIECES
ITEM 002
QUANTITY: ≥ 10,000 PIECES
ITEM 003
QUANTITY: ≥ 1,000 PIECES
MARKS: THIS PROTECTIVE CLOTHING/ISOLATION CLOTHING NOT INCLUDED SHOES COVER, NOT USED IN ICU.
Learn More -
T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTERREFERENCE NUMBER: T-6545
MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
PRODUCT INTRODUCTION:
MASK BACTERIA FILTRATION EFFICIENCY KEY PERFORMANCE INDICATORS (BFE) DETECTOR TESTER NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASKS TECHNOLOGY YY0469-2011 APPENDIX B IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST B. 1.1.1 TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL ASTMF2100, ASTMF2101, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING,IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENTIFIC RESEARCH INSTITUTES, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY.
EXECUTION STANDARD:
Q/0212 ZRB003-2015 MEDICAL SURGICAL MASK
BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR RELATED INTELLECTUAL PROPERTY:
NO.: ZL200820224142.6 ELECTRIC FLOW CONTROL VALVE
NO.: ZL200820224143.0 GAS CAPACITY
NO.: ZL200920308391.8 AIR FILTRATIONMATERIAL FILTRATION EFFICIENCY DETECTOR
PRODUCT FEATURES:
NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS;
BUILT -IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET, A, B TWO -WAY, SIX ANDERSEN; THE PERISTALTIC PUMP FLOW CAN BE SET;
THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD.
EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL; 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN;
USB INTERFACE, SUPPORT U DISK DATA STORAGE;
CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS; BUILT-IN LEAKAGE PROTECTION SWITCH TO PROTECT THE SAFETY OF OPERATORS;
THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT.
THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE.
DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT; SUPPORTING AND MOVING DUAL PURPOSE CASTERS.
QUANTITY: 1
Learn More