Search results for: 'control+pr'
- Related search terms
- control+prog
- control+pro
- control+programs
- control+pro'[0]
- control+pro'[0]'
-
M-3781 BENNINGER DIMENSA MERCERIZING MACHINE YEAR 2005 WORKING WIDTH 1800mmREFERENCE NUMBER: M-3781 (99056WOWZ8RC) K BENNINGER DIMENSA MERCERIZING MACHINE YEAR 2005 WORKING WIDTH 1800mm TYPE BENNINGER DIMENSA MSG LG ZT YOC. 2005 (INSTALLED END OF 2005) MAX FABRIC WIDTH 1.8 MT QUANTITY AVAILABLE: 1 Learn More -
M-1841 STORK STEAMER YEAR 1997 WIDTH 3600mmREFERENCE NUMBER: M-1841 (770PSJEXX6) STORK STEAMER YEAR 1997 WIDTH 3600mm BRAND: STORK STEAMER WORKING WIDTH: 3600mm FABRIC CAPACITY: 358 M HEAT AND SPEED CONTROL BY PC PROPORTIONAL STEAM CONTROL THERMAL OIL AND STEAM HEATED SUITABLE FOR PIGMENT, RONGEANT OR REAGENT PRINTED FABRICS RUNNING YEAR: 1997 QUANTITY available: 1 Learn More -
M-5283 ELMARCO NANOSPIDER PRODUCTION LINEREFERENCE NUMBER: M-5283 (13131CKAKT12U) L ELMARCO NANOSPIDER PRODUCTION LINE NANOSPIDER PRODUCTION LINE NS 4S1000U QUANTITY AVILABLE: 1 Learn More -
M-5202 KB10 REBEAMER FOR ACETATE WITH DISK BRAKES - TSUDAKOMAREFERENCE NUMBER: M-5202 (1313VTYFXX12) L KB10 REBEAMER FOR ACETATE WITH DISK BRAKES - TSUDAKOMA QUANTITY AVAILABLE: 1 Learn More -
T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASKREFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More -
R-6969 GAMATEX SIZING MACHINE, YEAR 1988REFERENCE NUMBER: R-6969
Learn More
MAKE: GAMATEX
TYPE: BM 85
QUANTITY: 1 -
J-1282 WEST POINT SIZING MACHINE WITH DOUBLE SIZE BOX, YEAR 1998REFERENCE NUMBER: J-1282
Learn More
WEST POINT SIZING MACHINE WITH DOUBLE SIZE BOX
YEAR: 1998
QUANTITY: 1 -
T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More -
P-5392 FEHRER NL28 PRE NEEDLE LOOM WIDTH 2600mmREFERENCE NUMBER: P-5392
FEHRER NL28 PRE NEEDLE LOOM WIDTH 2600mm
FEHRER
TYPE: NL28
PRE NEEDLE LOOM
WORKING WIDTH: 2600mm
SINGLE BOARD
QUANTITY: 1
Learn More -
L-4855 MASCOE COATING MACHINE, MODEL 5KC, YEAR 2006 (2000mm)REFERENCE NUMBER: L-4855
MASCOE COATING MACHINE, MODEL 5KC, YEAR 2006 (2000mm)
MAKE: MASCOE
YEAR: 2006
MODEL: 5KC
QUANTITY: 1
Learn More