Search results for: 'pro+4+pro'
- T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
REFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More - T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
REFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More - T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
REFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More - T-6589 KN95 FACE MASK
REFERENCE NUMBER: T-6589
KN95 FACE MASK
MATERIAL: 5LAYERS MATERIAL NOSE CLIP LINE, 3D FILTER AGAINST DROPLET
SIZE: 197X 136X 16mm
COLOR: WHITESAFE,BREATHABLE AND HYPOALLERGENIC;AND HIGH FILTRATION,CAPACITY.
PROVIDE SOME PROTECTION AGAINST DUST, OR SOME POISONOUS THINGS
PACKING:5PCS/OPP BAG CARTON SIZE: 700 X 500 X 500mm
2500PCS/CARTON
G.W: 15 KG
REMARK: ACCEPT CUSTOM LOGO
LEAD TIME -SHIPPINGTIME: 5-7 DAYS BY FEDEX, MASS GOODS: 2-4DAYS
ITEM 001
QUANTITY: 1,000
ITEM 002
QUANTITY: 5,000
ITEM 003
QUANTITY: 10,000
LEAD TIME -SHIPPINGTIME: 5-7 DAYS BY FEDEX, MASS GOODS: 5-7 DAYS
ITEM 004
QUANTITY: 50,000
ITEM 005
QUANTITY: 100,000
Learn More - P-8696 ULTRASONIC SEWING MACHINE
REFERENCE NUMBER: P-8696
ULTRASONIC SEWING MACHINE
CAN BE USED WITH EITHER 20 KHz, 30 KHz OR 40 KHz EQUIPMENT
LED DISPLAY FOR EASY PROCESS MONITORING
19” (483mm) THROAT
INDEPENDENT CONTROLS FOR SLITTING AND ROTARY ANVIL WELDING
DUAL SEALING CAPABILITIES WITH INDEPENDENT ADJUSTMENTS
EDGE GUIDING, REWINDING, AND FEED ROLLS CAN BE USED
CAN BE OPERATOR CONTROLLED AS A BENCHTOP UNIT OR INTEGRATED INTO AN EXISTING LINE
QUANTITY: 1
- T-6577 PROTECTION SUIT WITH SHOE COVER
PROTECTION SUIT WITH SHOE COVER
Learn More
HOODED DESIGN
HOODED HEAD DESIGN
ELASTIC DESIGN AT THE MOUTH
CAN ISOLATE DUST AND MICROORGANISMS
SEALED AND PROTECTED BY RUBBER STRIPS
THE WHOLE PIECE DESIGN
EASY TO PUT ON AND TAKE OFF
ELASTIC CUFFS, FLEXIBLE, EFFECTIVE BARRIER, EASIER TO USE
ELASTIC WAISTBAND SLIM ELASTIC WAISTBAND DESIGN, CLOSE THE WAIST, WORK MORE FREELY
CERTIFICATE: CE
MOQ: 1000PCS
MODEL: CONJOINED SPECS: S/160, M/165, L/170, XL/175, XXL/180 ALL SIZES ARE AVAILABLE, PRICES ARE SAME
TYPE:
NON-STERILE: 9.5KG/BOX, 30PCS/BOX, 560 X 430 X 360mm
STERILIZED FOR HOSPITAL: 13KG/BOX, 40PCS/BOX, 600 X 400 X 450mm
PRODUCT DESCRIPTION: CLOTHING MADE FROM FABRICS WITH ISOLATION FUNCTION SUCH AS VIRUS-CONTAINING AEROSOLS AND VIRUS-CONTAINING LIQUIDS. WHEN TAKEN OFF, THE OUTER SURFACE OF THE PROTECTIVE CLOTHING SHOULD NOT COME IN CONTACT WITH THE HUMAN BODY. THIS PRODUCT DOES NOT HAVE FLAME RETARDANT PROPERTIES.
INTENDED USE: OCCUPATIONAL PROTECTIVE CLOTHING FOR MEDICAL PERSONNEL IN MEDICAL INSTITUTIONS TO PREVENT THE TRANSMISSION OF VIRUSES FROM PATIENTS TO THE MEDICAL PERSONNEL WITH AIR OR LIQUID. - T-6576 MEDICAL SAFETY GOGGLES
MEDICAL SAFETY GOGGLES
Learn More
DISPOSABLE STERILIZED RUBBER SURGICAL GLOVES EYE PROTECTOR
PACKING SPECS 50 PAIRS/CARTON
DIMENSION 520 X 440 X 330mm; 5.46KG FOR ONE CARTON
CERTIFICATE: CE
MOQ 1 CARTON
ITEM 001
QUANTITY: 120PCS-1,200PCS
ITEM 002
QUANTITY: 1,201PCS-12,000PCS
ITEM 003
QUANTITY: ≥12,000PCS - T-6575 NON-INVASIVE VENTILATOR
NON-INVASIVE VENTILATOR
Learn More
CERTIFICATE: CE
MEDICAL VENTILATOR
TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
VENTILATOR TYPE: ELECTRIC CONTROL
SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
*VENTILATION MODE: CPAP, S, S/T, T
PRESSURE RANGE:
PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
PRESSURE ACCURACY: + 0.5CMH2O
PARAMETER SETTING:
DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
INSPIRATORY PHASE PRESSURE: 4-30CMH2O
EXPIRATORY PRESSURE: 4-30CMH2O
EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
INSPIRATORY SENSITIVITY: 1-8 STALLS
EXPIRATORY SENSITIVITY: 1-8 STALLS
RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
INSPIRATORY TIME: 0.3-3.0S
BACKUP RATE: ON / OFF, DEFAULT 10
PRESSURE RISE TIME: 1-4 STALLS
HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
*TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
*DATA MANAGEMENT:
NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
PARTS:
SD CARD: STANDARD
SD CARD SLOT: STANDARD
PIPING: 9 22MM, 1.8M LONG
FACE SHIELD: F2 NOSE MASK AS STANDARD
NOISE: LESS THAN 30DB
ENVIRONMENT CONDITION:
TEMPERATURE:
(WHEN USED) 5 -35 C
(DURING TRANSPORTATION AND STORAGE) -20 C -55 C
ATMOSPHERIC PRESSURE:
(WHEN USED) 760-1060HPA
(DURING TRANSPORTATION AND STORAGE) 760-1060HPA
WORKING HOURS: MORE THAN 8 HOURS
POWER SUPPLY REQUIREMENTS:
AC VOLTAGE: 100-240V
FREQUENCY: 50HZ/60HZ
INPUT POWER: LESS THAN 2A
WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
INSTRUMENT SIZE: 290mm X 180mm X 134mm
WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
ITEM 001
QUANTITY: 10 SETS-999 SETS
ITEM 002
QUANTITY: 1,000 SETS-9,999SETS
ITEM 003
QUANTITY: ≥10,000 SETS - J-2792 MEDICAL FACE MASK SYNTHETIC BLOOD PENETRATION TESTER
USED FOR MEASURING THE RESISTANCE OF MEDICAL FACE MASKS TO PENETRATION BY A SPLASH OF SYNTHETIC BLOOD
BLOOD SPRAYING DISTANCE: 300 TO 310mm (APPROXIMATE, ADJUSTABLE)
NEEDLE INNER DIAMETER: 0.84mm
SPRAY SPEED: 4500mm PER SECOND, 5500mm PER SECOND, 6350mm PER SECOND
SIMULATED SYNTHETIC BLOOD PRESSURE: 10.6kPa, 16.0 kPa, 21.3 kPa, (i.e. 80mmHg, 120mmHg, 160mmHg)
SUPPORTS THE SPECIMEN MEDICAL FACE MASK ON THE TESTER’S CLAMPING DEVICE AND SPRAYS A FIXED VOLUME (~2ml) OF SYNTHETIC BLOOD SPLASHED HORIZONTALLY TO HIT THE MASK
TESTER CAN PROVIDE DIFFERENT BLOOD PRESSURES WITH PRECISION CONTROL VALVE TO GENERATE 2ml SYNTHETIC BLOOD WITH SURFACE TENSION OF 0.042 ± 0.002 N/m, WHICH MEETS THE REQUIREMENTS DEFINED IN STANDARDS BELOW:
ISO 22609
ASTM F1862
YY 0469-2011
GB/T 19083-2010LEAD TIME: 5 TO 7 WEEKS FROM RECEIPT OF ORDER
QUANTITY: 1
Learn More - J-2216 DOWN & FEATHER FILLING MACHINE, 4 WEIGH SCALES, 1 NOZZLE, 1400 GRAMS PER FILL -1400 GRAMS PER FILL
FOR FILLING DOWN FEATHER PILLOWS
FILLING RANGE: 1 TO 120 GRAMS (70% FEATHER & 30% DOWN)
WEIGHING SYSTEM: 4 SETS
POWER: 4.5 KW
VOLTAGE: 220 / 380 V, 3-PHASE
AIR PRESSURE: 0.5 TO 0.7 MPA
ACCURATE WEIGHING RESULTS WITH TOLERANCE OF ONLY 1 GRAM
WORKING TABLE DIMENSIONS: 1200 x 2400mm (FOR CUSTOMERS FILLING PILLOWS AND QUILTS)
WORKING TABLE DIMENSIONS FOR PILLOWS ONLY: 1200 x 1200mm (EASIER TO FIT IN A 20 FOOT CONTAINER)
OPERATION CAN BE HANDLED BY ONLY 1 EMPLOYEE
INCLUDES ONE AUTOMATIC FILLING TABLE WITH FOOT SWITCH AND CLAMP DEVICE
THE WORKER STEPS ON THE FOOT SWITCH AND THE CLAMP DEVICE WILL RUN TO CLAMP THE PILLOW BAG
THE FILLING PROCESS AUTOMATICALLY STARTS TO FILL THE PILLOW AND AFTER FINISHING THE CLAMP DEVICE WILL RESET
DURING THIS PERIOD, THE WORKER MAY SEAL THE PILLOW WITH SEWING MACHINE
FOUR HOPPER SYSTEM FOR CONSTANT SUPPLY
ONE KEY FOR CHARGE AND RECHARGE REDUCES WASTED TIME
HIGH-QUALITY, RELIABLE ELECTRICAL COMPONENTS
PREPROGRAMMABLE FOR UP TO 50 GROUPS OF RECIPES WITH EACH RECIPE CONTAINING UP TO 60 SETS OF DIFFERENT FILLING PARTS FOR THE SAME PRODUCTION
FULLY ENCLOSED DESIGN TO KEEP ENVIRONMENT CLEAN AND REDUCE MATERIAL WASTE
AUTOMATIC, ACCURATE WEIGHING WITH LOAD CELL TO ENSURE PRODUCTION QUALITY
CE CERTIFICATE INCLUDED
FLOORSPACE 4000mm LONG X 3000mm WIDE X 2500mm HIGH
TABLE FOR PILLOWS IS 1200 X 1200mm
Learn More
QUANTITY: 1