Search results for: 'contr'
- Related search terms
- Contro'
- Control+pa'||'
- Control pa'||'
- Control+pan''
- Control+pa'"'
- DORNIER TUBULAR MERCERIZING MACHINE FOR KNIT FABRICS, WORKING WIDTH 1700mm, YEAR 2008REFERENCE NUMBER: T-6705 DORNIER TUBULAR MERCERIZING MACHINE FOR KNIT FABRICS, WORKING WIDTH 1700mm, YEAR 2008 DORNIER TUBULAR MERCERIZING MACHINE FOR KNIT FABRICS YEAR 2008 WORKING WIDTH 1700mm 2 CIGER 2 CHEMICAL TANKS WITH COOLING SYSTEM SIMENS CONTROLLER Learn More
- JENBACHER LMS612GS GAS POWER PLANT, 2 MW, 50 Hz, YEAR 2011REFERENCE NUMBER: T-6935 JENBACHER LMS612GS GAS POWER PLANT, 2 MW, 50 Hz, YEAR 2011 JENBACHER LMS612GS GAS POWER PLANT COMPLETE POWER PLANT 2,000 KW COP 11,000 V, 50 Hz AVK ALTERNATOR 1,500 RPM RADIATOR, SILENCER, EXHAUST, GAS CONTROL LINE YEAR 2011 APPROX 230 H ONLY QUANTITY: 1 Learn More
- MCS HIGH TEMPERATURE DYE JIGGER, WIDTH 2000mm, YEAR 1999REFERENCE NUMBER: T-6920 MCS HIGH TEMPERATURE DYE JIGGER, WIDTH 2000mm, YEAR 1999 BRAND: MCS ITALY YEAR 1999 ROLLER WIDTH 2000mm BOILER DIAMETER 1800mm SUITABLE FOR 400 KG OF FABRIC INFEED AND EXIT BY BATCH WINDER ALL SERVOMOTOR DRIVEN (NO HYDRAULIC) MCS CT 401 CONTROL DEVICE EXPANSION VESSEL (MACHINE IS IN WAREHOUSE) MACHINE IS IN EXCELLENT CONDITION QUANTITY: 1 Learn More
- SPINNBAU DOUBLE DOFFER NON-WOVEN CARD 2500mmREFERENCE NUMBER: Y-2075 SPINNBAU DOUBLE DOFFER NON-WOVEN CARD 2500mm RECONDITIONED CARD SPECIFICATION: 2500mm WORKING WIDTH DISH FEEF ARRANGEMENT WITH FEED ROLLER 159mm 1 LICKER-IN 292mm 1 BREAST 412mm WITH 1 WORKER 213mm AN 1 STRIPPER 105mm 1 TRANSFER 412mm 1 SWIFT 1500mm WITH 6 WORKERS 213mm AND 6 STRIPPERS 105mm 1 TOP DOFFER 500mm 1 BOTTOM DOFFER 550mm 2 BOTTOM RANDOMISER ROLLERS 292mm 2 BOTTOM RANDOMISER ROLLERS 292mm TOP DOFFER DOFFING ROLLER SYSTEM 2 ROLLER 105mm AND 105mm CARD MOUNTED ON RAILS WITH PLATFORM SPINNBAU GUARDING SYSTEM FITTED WITH THE FOLLOWING NEW EQUIPMENT: NEW HIGH CAPACITY HOPPER FEEDER WITH CHUTE DELIVERY ELECTRONIC WEIGHT SYSTEM NEW AC INVERTER DRIVES SYSTEM WITH TOUCH SCREEN CONTROL NEW AC GEARED MOTOR UNITS NEW DRIVE BELTS AS REQUIRED NEW SAFETY CIRCUIT, E-STOPS AND GUARD INTERLOCKS HOPPER FEEDER WITH CHUTE DELIVERY 2500mm WIDE 1500mm FEEDER CONVEYOR PVC WITH WOOD LATHS WITH GEARED MOTOR DRIVE INCLINED SPIKED LATTICE PVC WITH WOOD LATHS WITH GEARED MOTOR DRIVE LEVELLING ROLLER WITH GEARED MOTOR DRIVE STRIPPING ROLLER WITH GEARED MOTOR DRIVE VOLUMETRIC CHUTE DELIVERY VIBRATING BACKPLATE WITH GEARED MOTOR DRIVE CHUTE THICKNESS ADJUSTABLE DELIVERY ROLLERS TO BE DRIVEN FROM CARD FEED SHEET ELECTRICAL CONTROLS WITH VARIABLE SPEED DRIVE TO SPIKED LATTICE, OR STRIPPING ROLLERS AND VIBRATING BACKPLATE QUANTITY: 1 Learn More
- AUTEFA, DILO, SPINNBAU COMPLETE NONWOVEN LINEREFERENCE NUMBER: T-6855 AUTEFA, DILO, SPINNBAU COMPLETE NONWOVEN LINE BRAND: AUTEFA, DILO, SPINNBAU SHORT DESCRIPTION: COMPLETE NONWOVEN LINE ITEM 001 SINGLE DOFFER CARD BY “BESSI” - ITALY YEAR 1966 - WORKING WIDTH 2500mm - HOPPER-FEEDER WITH SCALE (WEIGHPAN) AND TOP SILO - INLET UNIT WITH ROLLERS - BREAST UNIT DIAMETER 1500mm WITH 3 PAIRS WORKERS/ STRIPPER (ORIGINALLY EQUIPPED WITH 5 PAIRS, UNUSED 2 PAIRS STILL AVAILABLE) - FANCY ROLL - TRANSPORT ROLL DIAMETER 1200mm - SWIFT DIAMETER 1500mm WITH 3 PAIRS WORKERS/ STRIPPER (ORIGINALLY EQUIPPED WITH 5 PAIRS, UNUSED 2 PAIRS STILL AVAILABLE) - DOFFER DIAMETER 1500mm WITH FLY-COMB - FLEXIBLE AND RIGID METALLIC WIRES IN EXCELLENT CONDITIONS QUANTITY: 1 ITEM 002 CROSS-LAPPER BY “MAK-AUTEFA” - GERMANY MODEL 101-42 YEAR 1965 - INLET WORKING WIDTH 2500mm - EXIT WORKING WIDTH 3000mm QUANTITY: 1 ITEM 003 PRE-NEEDLER BY “DILO” - GERMANY MODEL NFZ 3000 YEAR 1967 - WORKING WIDTH 3000mm - 2 NEEDLE BOARDS WITH TOTALLY 3000 NEEDLES / LIN MT - WITH BATT INLET UNIT QUANTITY: 1 ITEM 004 FINISH NEEDLERS BY “DILO” MODEL OD II 25 YEAR 1979 EACH - WORKING WIDTH 2500mm EACH - EACH ONE WITH 2 NEEDLE BOARDS WITH TOTALLY 5000 NEEDLES / LIN MT QUANTITY: 2 ITEM 005 TRANSVERSAL CUTTER BY “SPINNBAU-AUTEFA” - GERMANY. YEAR 1973 - WORKING WIDTH 2500mm QUANTITY: 1 ITEM 006 LONGITUDINAL CUTTER ITALIAN MAKE + ROLL WINDER ITALIAN MAKE ON ELECTRONIC WEIGHTING CELLS. WORKING WIDTH 2500mm QUANTITY: 1 ITEM 007 ROLLS LIFTING CRANE QUANTITY: 1 ALL ELECTRIC MOTORS AND CONTROL PANELS 400 V / 50 Hz Learn More
- HERGETH, HUNTER SPRAY BOND LINE, YEAR 1980 TO 1990REFERENCE NUMBER: T-6851 HERGETH, HUNTER SPRAY BOND LINE, YEAR 1980 TO 1990 BRAND: HERGETH, HUNTER SHORT DESCRIPTION: SPRAY BOND LINE YEAR: 1980 TO 1990 SPRAY BOND LINE, 160” CONSISTING OF: 1 FIBER CONTROL BLEND LINE (3 HOPPERS - 2-60” AND 1-36” W/FLOOR CONV.) 1 HUNTER BLEND LINE (3 HOPPERS- 72” 48”, 36” W/ FLOOR CONV.) 1 HERGETH BLEND LINE (4 HOPPERS- 36” W/FLOOR CONV.) 3 HERGETH FINE OPENERS 1200mm WIDE 3 SPINBAU 2000mm CARDS WITH CHUTE FEEDS 3 CROSSLAPPERS 160” WIDE (P&S/ WISE) 1 P&S SPRAY STATION - 160” 1 P&S 160” FLUTE OVEN 2 TEMP ZONES 2000mm BTU EACH P&S SLITTERS 9 KNIFES W/HOT WIRE CUTOFF AND 2 ROLL WINDER ALL FLOOR CONVEYORS AND SUPPORT EQUIPMENT CLARK 48 INCH 4 BARS CLAW PICKER FOR RECYCLE ALL EQUIPMENT RUNS ON 220/440 3 PHASE LATE 1980S-EARLY 90S THIS LINE IS CURRENTLY RUNNING QUANTITY: 3 Learn More
- T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
REFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More - T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
REFERENCE NUMBER: T-6545
MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
PRODUCT INTRODUCTION:
MASK BACTERIA FILTRATION EFFICIENCY KEY PERFORMANCE INDICATORS (BFE) DETECTOR TESTER NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASKS TECHNOLOGY YY0469-2011 APPENDIX B IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST B. 1.1.1 TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL ASTMF2100, ASTMF2101, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING,IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENTIFIC RESEARCH INSTITUTES, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY.
EXECUTION STANDARD:
Q/0212 ZRB003-2015 MEDICAL SURGICAL MASK
BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR RELATED INTELLECTUAL PROPERTY:
NO.: ZL200820224142.6 ELECTRIC FLOW CONTROL VALVE
NO.: ZL200820224143.0 GAS CAPACITY
NO.: ZL200920308391.8 AIR FILTRATIONMATERIAL FILTRATION EFFICIENCY DETECTOR
PRODUCT FEATURES:
NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS;
BUILT -IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET, A, B TWO -WAY, SIX ANDERSEN; THE PERISTALTIC PUMP FLOW CAN BE SET;
THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD.
EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL; 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN;
USB INTERFACE, SUPPORT U DISK DATA STORAGE;
CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS; BUILT-IN LEAKAGE PROTECTION SWITCH TO PROTECT THE SAFETY OF OPERATORS;
THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT.
THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE.
DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT; SUPPORTING AND MOVING DUAL PURPOSE CASTERS.
QUANTITY: 1
Learn More - T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
REFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More - T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
REFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More