Search results for: 'Form Z'
- Related search terms
- forming materials
- forma
- formia n
- formia nuo
- FORMULA 1
-
M-6053 SPUNBOND PRODUCTION LINE, WORKING WIDTH 4040mm TO 4500mmM-6053 SPUNBOND PRODUCTION LINE, WORKING WIDTH 4040mm TO 4500mm
OFFER 001
SPUNBOND PRODUCTION LINE
WORKING WIDTH: 4040mm
WEIGHT: 130 TO 250 G/M2OFFER 002
POLYMER CLEANING GROUPOFFER 003
CRYSTALLIZING GROUPOFFER 004
DRYING GROUPOFFER 005
PNEUMATIC CONVEYING SYSTEMOFFER 006
EXTRUDER HOPPEROFFER 007
EXTRUDEROFFER 008
FILTERING UNITOFFER 009
MELT TRANSFER LINEOFFER 010
SPINNING BEAMOFFER 011
SPINNING PACKSOFFER 012
FILAMENTS QUENCHING SYSTEMOFFER 013
FILAMENTS DRAWING AND DISTRIBUTION SYSTEMOFFER 014
WEB FORMING CONVEYOR BELTOFFER 015
CREEL FOR APPLICATION OF REINFORCING FILAMENTSOFFER 016
PRE-NEEDLING MACHINEOFFER 017
NEEDLING MACHINEOFFER 018
THERMOSETTING UNITOFFER 019
OUTLET CALENDEROFFER 020
FOULARDOFFER 021
BINDER PREPARATION SYSTEMOFFER 022
DRYEROFFER 023
OUTLET CALENDEROFFER 024
AUTOMATIC WINDEROFFER 025
AIR COMPRESSORS (FOR FILAMENTS STRETCHING EJECTORS)OFFER 026
DIATHERMIC OIL HEATING SYSTEMOFFER 027
CHILLED WATER CIRCULATION AND GENERATION SYSTEMOFFER 028
EQUIPMENT FOR CLEANING CYCLE, SPECIAL TOOLSOFFER 029
FIBRE DUST RECOVERY SYSTEMOFFER 030
EDGES RECOVERY SYSTEMOFFER 031
SPINNING SECTION STEEL STRUCTUREOFFER 032
DISTRIBUTION ELECTRIC CABINETSOFFER 033
PROCESS ELECTRIC SYSTEM OF EXISTING MACHINES ACCORDING TO THE ACTUAL LAYOUTOFFER 034
CABLES AND CABLING MATERIALSQUANTITY: 1 LINE
Learn More -
M-3984 RING SPINNINGREFERENCE NUMBER: M-3984
RING SPINNING
(1) TRUTZSCHLER BLENDOMAT BDT 019, YEAR 1990
(1) TRUTZSCHLER BLENDER GBRA 1000, YEAR 1990
(1) TRUTZSCHLER AXIFLOW AFC, YEAR 1990
(1) TRUTZSCHLER MULTIMIXER MPM8/1400, YEAR 1990
(1) TRUTZSCHLER SEPAROMAT ASTA 800, YEAR 1990
(2) TRUTZSCHLER SILO BEB 1200, YEAR 1990
(2) TRUTZSCHLER FIBER OPENER RST, YEAR 1990
(5) TRUTZSCHLER CONDENSER LVSA, YEAR 1990
(4) TRUTZSCHLER FAN TV 425, YEAR 1990
(2) TRUTZSCHLER FAN TVF 425, YEAR 1990
(3) TRUTZSCHLER FAN TV 500, YEAR 1990
(1) TRUTZSCHLER FAN TVK 650, YEAR 1990
(3) TRUTZSCHLER FILTER SFV 123, YEAR 1990
(1) TRUTZSCHLER FILTER SFF 3, YEAR 1990
(3) TRUTZSCHLER CYCLON ANB AT, YEAR 1990
(1) TRUTZSCHLER FEED TABLE (OPENING) M30 S/C, YEAR 1990
(2) TRUTZSCHLER FEED TABLE (FILTER) S/N S/C, YEAR 1990
(1) TRUTZSCHLER FEED TABLE (CARDS), YEAR 1990
(14) TRUTZSCHLER CHUTE FEED FBK 533, YEAR 1990
(5) RIETER DRAW FRAME SB2, CAN SIZE 1000x1200mm, YEAR 1997
(2) RIETER DRAW FRAME RSB D30, CAN SIZE 500x1000mm, YEAR 1999
(3) RIETER DRAW FRAME RSB 951, CAN SIZE 600x1200mm, YEAR 1997
(2) ZINSER/HARA LAP FORMER 820, 20 POSITIONS, 1000x1040mm, YEAR 1990
(12) ZINSER/HARA COMBER 830, CAN SIZE 500x1200mm, YEAR 1990
(1) ELECTRONIC CLEANER PANEL, YEAR 1990
(5) ZINSER ROVING FRAME 660, 120 POSITIONS, 16x6, CAN SIZE 500x1000mm, YEAR 1990.
(3) SOHLER AIRTEX OVERHEAD BLOWER SP 88 ZB, YEAR 1990
(20) ZINSER RING FRAME 321E, 1000 SPINDLES, RING DIA 45mm, GAUGE 75mm, YEAR 1990
(10) SOHLER AIRTEX OVERHEAD BLOWER AP 88 ZZ WI, YEAR 1990
(1) SUCTION FAN, YEAR 1990
(4) MURATA WINDER 7 II (MACH CONER), 60 POSITIONS, WITH LUWA OVERHEAD BLOWER, YEAR 1990
(1) XORELLA STEAMER CONTEXXOR, YEAR 1990
Learn More -
M-4089 COMPLETE RIETER RING SPINNING & YARN DYE FACTORY – 37,056 SPINDLES - Will Sell IndividuallyREFERENCE NUMBER: M-4089 (990DJSKXX8) L
COMPLETE RIETER RING SPINNING & YARN DYE FACTORY – 37,056 SPINDLES- will sell individually
FACTORY WAS PRODUCING VARIOUS SPECIALTY YARNS FOR USE IN APPAREL AND TECHNICAL TEXTILES
ALL RING FRAMES SHORT STAPLE FOR FIBERS UP TO 40mm, 220mm TUBES, APPROXIMATELY HALF OF THE RING FRAMES ARE WITH PINTER CORE DEVICE OR AMSLER SLUBBING DEVICE. AMSLER AND PINTER AVAILABLE TO SELL SEPARATELY.
COMPLETE YARN DYE HOUSE & DYE LAB
QUANTITY AVAILABLE: 1
Learn More -
T-6552 MASK AIR TIGHTNESS TESTERREFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
Learn MoreMASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 -
V-1468 COTTON GAUZE MEDICAL COMPRESS FOLDING AND BAGGING MACHINE, WHICH AUTOMATICALLY FOLDS COTTON GAUZE COMPRESSESREFERENCE NUMBER: V-1468
SURGICAL GAUZE COMPRESSING, FOLDING, AND BAGGING MACHINE
COTTON GAUZE MEDICAL COMPRESS FOLDING AND BAGGING MACHINE, WHICH AUTOMATICALLY FOLDS COTTONG GAUZE, COMPRESSES, AND THEN PACKS THEM INDIVIDUALLY OR IN GROUPS INTO SACHETS.
FEATURES
USEFUL WIDTH: 45 CM
NUMBER OF TRACKS: MAXIMUM 2 (VARIES ACCORDING TO THE SIZE OF COMPRESSES)
SIZE:
MINIMUM DIMENSIONS OF COMPRESSES: 5 CM X 5 CM
MAXIMUM DIMENSIONS OF COMPRESSES: 10 CM X 20 CM (16 PLIES)
ALL THE USUAL OR INTERMEDIATE SIZES CAN BE PRODUCED ON THE MACHINE BY SIMPLE ADJUSTMENTS.
NUMBER OF PLIES 8 / 12 / 16 / 20 / 24 / 28 / 32 PLIES (VARIES ACCORDING TO THE SIZE OF COMPRESSES)
FOLDING: THE CONVENTIONAL FOLDING IS THE 5-FOLD "SURGICAL" OR "AMERICAN" TYPE, WITH EDGES AND CORNERS TUCKED-IN, HOWEVER BY OFFSETTING FOLDS OTHER COMBINATIONS ARE POSSIBLE.
STACKING: STACKING IS CARRIED OUT IN THE CHANNELS WHERE THE COMPRESSES ARE COUNTED AND READY TO BE MANUALLY INSERTED INTO PAPER BAGS.
PRODUCTION :
EXAMPLES OF THEORETICAL PRODUCTIONS:
5 CM X5 CM 8 PLIES (2 TRACKS) 13200 COMPRESSES PER HOUR
7.5 CM X 7.5 CM 12 PLIES (2 TRACKS) 13200 COMPRESSES PER HOUR
10 CM X 10 CM 12 PLIES (2 TRACKS) 12000 COMPRESSES PER HOUR
OPTIONS:
BARIUM FIXING TRACK BY TRACK
GAUZE ROLL LOADING BY PNEUMATIC CYLINDERS"
FEATURES LIST:
MATERIAL SUPPORT ADJUSTABLE IN WIDTH,
POSITIVE UNWINDING WITH TENSION CHECK ADJUSTABLE TRACK BY TRACK,
MULTIPLE LENGTH FOLDING DEVICE ADJUSTABLE TRACK BY TRACK,
SPRAY HUMIDIFYING SYSTEM,
SUCTION SYSTEM,
ANTI-STATIC BARS,
ADJUSTABLE FLY CUT MODULE MOTORISED WITH BRUSHLESS MOTOR,
THREE CROSS FOLDING MECHANISMS WITH INDEPENDENT ADJUSTMENT OF EACH FOLD,
TRANSFER BELTS FOR THE COMPRESSES,
MOTORISED LATERAL UNWINDING OF THE PAPER ROLL MODULE,
DEVICE FOR INDIVIDUAL, IN MULTIPLES OR IN SHINGLED FORM PACKAGING - WITH A CHANGEABLE
NUMBER OF COMPRESSES BY SACHET,
CHECK OF FOLLOWING OPERATIONS TRACK BY TRACK:
. END OF FABRIC,
. PRESENCE OF SEAM,
. PRESENCE OF CROSS-FOLDED COMPRESS,
. JAM PREVENTION BEFORE PACKAGING.
COLD SEALING BY PRESSURE AND CUTTING OF SACHETS IN PRINTED AND ZONED PAPER,
POWER SYSTEM OF PACKAGING BY BRUSHLESS MOTOR ALLOWING FOR FLY ADJUSTMENT OF:
. THE COMPRESS POSITION IN THE SACHET,
. THE CROSSWISE KNURLING POSITION,
. THE CROSSWISE CUTTING OF SACHETS.
ACCELERATION RAMP BY FREQUENCY VARIATION,
MACHINE OPERATION BY TOUCH-SENSITIVE SCREEN:
. STORABLE CONFIGURATIONS,
. CLEAR LANGUAGE FAULT DISPLAY,
. COUNTERS : TOTALIZER, PRE-SELECTION, ETC.,
. SOUND AND VISUAL ALARMS,
. "INCIDENT" STATISTICS.
STARTING, STOPPING, STEP BY STEP - BY REMOTE CONTROL.
* CONTINUOUS, TRACK BY TRACK INTEGRATION OF ULTRASONIC BARIUM FIXING.
* PAPER ROLL LOADING BY PNEUMATIC CYLINDERS.
* INK JET MARKING UP TILL 8 LINES.
* SACHETS QUALITY CONTROL DEVICE: EITHER A CHECK BY PHOTO CELLS, OR BY CAMERAS,
* FAULTY SACHET EJECTION DEVICE.
* TABLE WITH CONVERGING BELTS.
Learn More