Search results for: 'Part's t'
- Related search terms
- Part's
- Part's ta
- Part's tap
- Part's tape
- Part's tape ed
-
D-2380 AUTOMATED FILTER TESTERTHE AUTOMATED FILTER TESTER MODEL 9981 CONTINUES TO BE THE BEST SOLUTION FOR TESTING PARTICULATE RESPIRATOR FILTERS, DISPOSABLE FILTERING FACE PIECES, AND A WIDE ASSORTMENT OF FILTER MEDIA. OUR FILTER TESTERS HAVE BEEN USED IN QUALITY CONTROL AND MANUFACTURING BY LEADING FILTER AND FILTER MEDIA MANUFACTURERS AND REFERENCE TEST INSTITUTES AROUND THE WORLD FOR MORE THAN 20 YEARS DUE TO THEIR PROVEN DURABILITY AND RELIABILITY, WHICH IS VALUED IN DEMANDING MANUFACTURING ENVIRONMENTS AND QA/QC LABORATORIES.
THIS MODEL OFFERS HIGHER SENSITIVITY AND RESOLUTION THAN PREVIOUS MODELS - UP TO 99.9999 PERCENT EFFICIENCY HAS BEEN PRODUCED WITH EMERY OIL AT CONCENTRATIONS OF 200 MG/M³. THE NEW SERVICEABLE PHOTOMETERS ARE LOWERING THE COST OF OWNERSHIP AND ENABLE PROACTIVE SCHEDULING OF MAINTENANCE FOR MINIMAL IMPACT TO PRODUCTION SCHEDULES.
THE MODEL 9981 FEATURES A HIGH DEGREE OF AUTOMATION AND SELF-DIAGNOSTICS THAT GREATLY SIMPLIFIES OPERATION, INCREASES THROUGHPUT, AND IMPROVES OVERALL MEASUREMENT PERFORMANCE. WHEN LOOKING FOR A STAND-ALONE TESTER TO DETERMINE PENETRATION OR FILTER EFFICIENCY AND PRESSURE DROP OF YOUR MEDIA, FILTER CARTRIDGES, FILTERS, AND RESPIRATORY MASKS THE MODEL 9981 IS UP TO THE CHALLENGE.
THE BUILT-IN CAPABILITY TO TEST WITH SALT AND OIL MEANS THAT JUST ONE UNIT IS NEEDED TO TEST YOUR PRODUCT TO:
• US 42 CFR 84, GB2626, JMOL
• ISO 16900-3, EN 143
• ISO 23328-1 (AND MORE)
APPLICATIONS
• USA COMMERCIAL RESPIRATOR REGULATION 42 CFR PART 84
• CHINESE RESPIRATOR STANDARD GB2626
• JAPANESE RESPIRATOR STANDARD JMOL
• EUROPEAN EN 143, ISO 16900-3 AND RELATED RESPIRATOR STANDARDS
• ISO 23328-1 (TESTING FILTERS FOR ANAESTHETIC USE)
• FILTER MEDIA TESTING
• CONSULT OUR REPRESENTATIVE FOR MORE DETAILS
INCLUDED ITEMS
• REFERENCE MEDIA SHEETS
• FLAT-MEDIA AND GRAVIMETRIC FILTER HOLDER
• REFERENCE PRESSURE DROP PLATE
• OIL AND SALT AEROSOL GENERATORS
• SELECTED SPARE PARTS
• CONTACT US FOR CUSTOM FILTER HOLDERSEMAIL US FOR PRICE & PICTURES
Learn More
INCLUDE OUR REFERENCE NUMBER -
T-6582 MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)REFERENCE NUMBER: T-6582
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
1.NP3030: MEDICAL DISPOSABLE PROTECTIVE CLOTHING,STRONG RESISTANT
2.FABRIC: SF 66 G, COLOR: WHITE RUBBER:CAP/FOOT/CUFF/WAIST FRONT FLAP: DOUBLE-SIDED TAPE, TAPE:BLUE TAPE, ETHYLENE OXIDE DISINFECTION, STERILE
3.PACKAGED: 1PC/BAG, 32PCS/CARTON,10KG/CARTONCARTON SIZE: 470 X300 X420mm/CTN
4.NOTE: CLASS II MEDICAL TREATMENT, SCOPE OF USE: MEDICALPERSONNEL CONTACT WITH POTENTIALLY INFECTIOUS PATIENTSBLOOD, BODY FLUIDS, SECRETIONS, PARTICLES IN THE AIR TOPROVIDE BARRIER, PROTECTION. THIS PRODUCT IS USED FORISOLATION OF OBSERVATION WARD (ROOM), ISOLATION WARD(ROOM), ETC. IT IS STRICTLY PROHIBITED TO USE IN THE ISOLATIONCRITICAL CARE WARD (ROOM) AND OTHER PLACES WITH STRICTCONTROL OF MICROBIAL INDICATORS1PC/BAG, 32PCS/CARTON.
WEIGHT AND DIMENSIONS OF CARTONS: 10KG/CARTON
CARTONS IN A 20 FOOT CONTAINER: 370 BOXESSTERILIZED BY ETHYLENE OXIDE GAS
EACH PIECE IS INDIVIDUALLY VACUUM PACKED
1PER PLASTIC POUCH
QUANTITY: 10,000
Learn More -
T-6583 PROTECTIVE SUITREFERENCE NUMBER: T-6583
PROTECTIVE SUIT
TWO-PIECE HOODED DESIGN: WITH TWO-PIECE HOODED THREE-DIMENSIONAL CUT AND ELASTIC BAND AROUND THE FACE OPENING, THE HOOD CAN BETTER FIT THE SHAPE OF FACE AND ENHANCE THE PROTECTION EFFECT.
SEAM SEALED TAPE WORKMANSHIP: EACH SEAM IS SEALED WITH TAPE, AND THE WAIST IS APPLIED WITH AN INTERNAL ELASTIC BAND, WHICH BETTER ENHANCE THE SEAM PROTECTION AND THE FITNESS OF THE SUIT.
ELASTIC CUFF: THE CUFF USES AN INTERNAL ELASTIC BAND TO FURTHER ENHANCE TIGHTNESS AND PROTECTION.
CLOSED PLACKET DESIGN: CENTER FRONT ZIPPER APPLICATION ALLOWS EASY PUT-ON AND TAKE-OFF, WHILE THE ZIPPER PLACKET DESIGN BRINGS BETTER PROTECTION
TECHNOLOGICAL DETAILS: (1)NEEDLE STITCHING, BONDING, AND HEAT-SEALING PROCESSES ARE APPLIED TO THE CONNECTION PART OF THE PROTECTIVE SUIT. THE HOLES OF THE STITCHES ARE SEALED. THE STITCH PITCH SHOULD BE 8 TO 14 STITCHES PER 3CM. THE STITCHES ARE ALIGNED AND PROPERLY SPACED. THERE SHOULDN' T BE SKIPPED STITCH. BONDED OR HOT-SEALED PARTS SHALL BE FLAT AND SEALED WITHOUT AIR BUBBLES.
(2)THE ZIPPER OF THE PROTECTIVE CLOTHING SHOULD NOT BE EXPOSED,AND THE ZIPPER PULLER SHOULD BE SELF-LOCKING.
(3)THE STRUCTURE OF PROTECTIVE SUIT SHOULD BE IN CONFORMITY, EASY TO PUT ON AND TAKE OFF, AND THE JOINTS MUST BE TIGHT.
(4)ELASTIC CUFFS AND ANKLES, AND ELASTIC HOOD AND WAIST OPENINGS.
(5)THE PROTECTIVE SUIT IS IN OVERALL STRUCTURE,WHICH CONSISTS OF A HOODED TOP AND PANTS.
Learn More -
T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More -
T-6551 MASK FLAME RETARDANT PERFORMANCE TESTERREFERENCE NUMBER: T-6551
MASK FLAME RETARDANT PERFORMANCE TESTER
MASK FLAME RETARDANT PERFORMANCE TESTER
TECHNICAL INDEX:
1.THE LINEAR VELOCITY OF THE NOSE TIP OF THE DIE IS (60 ± 5) MM / S
2.THE DIAMETER OF FLAME TEMPERATURE MEASURINGPROBE IS 1.5MM
3.THE FLAME TEMPERATURE IS (800 ± 50) °C
4.THE DISTANCE BETWEEN THE BURNER TOP AND THE MASK IS (20 ± 2) MM
5.METAL DIE
APPLICABLE STANDARD:
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
YY 0469-2011 MEDICAL SURGICAL MASK
MEDICAL PROTECTIVE MASK REFERS TO A SELF-PRIMING FILTER TYPE DUST-PROOF MEDICAL PROTECTIVE MASK THAT CAN FILTER THE PARTICLES IN THE AIR AND BLOCK THE DROPLETS, BLOOD, BODY FLUIDS, SECRETIONS, ETC.
QUANTITY: 1
Learn More -
H-2366 MASK AND MEDICAL GOWN LABORATORY EQUIPMENTREFERENCE NUMBER: T-6334
Learn More
ALL KINDS OF MASK TESTING INSTRUMENTS
(SURGICAL MASK)
(DISPOSABLE SURGICAL MASK)
(MEDICAL PROTECTIVE MASK)
(DAILY PROTECTIVE MASK)
ITEM 001
COMPREHENSIVE TENSION TESTER FOR SURGICAL MASK
ITEM 002
MASK SYNTHETIC BLOOD PENETRATION DETECTOR
ITEM 003
BACTERIAL PERCOLATION EFFICIENCY (BFE) TESTER
ITEM 004
PARTICLE EFFICIENCY (PFE) TESTER
ITEM 005
RESPIRATOR RESISTANCE TESTER
ITEM 006
MASK FLAME RETARDANT PERFORMANCE TESTER
ITEM 007
FABRIC SURFACE MOISTURE TESTER
ITEM 008
MASK AIR TIGHTNESS TESTER
ITEM 009
TEMPERATURE PRETREATMENT CONSTANT TEMPERATURE AND HUMIDITY CHAMBER
ITEM 010
COLOR FASTNESS TO FRICTION TESTER
ITEM 011
TEXTILE FORMALDEHYDE TESTER
ITEM 012
PH METER
REFERENCE NUMBER: T-6335
RESPIRATORY PROTECTIVE EQUIPMENT & SELF-IMBIBITION FILTER ANTI-PARTICULATE RESPIRATOR TESTING INSTRUMENTS
ITEM 001
FIITRATION EFFICIENCY N CLASS SODIUM CHLORIDE PARTICLES, P CLASS OIL PARTICLES
PARTICLE RATE EFFICIENCY TESTER
ITEM 002
RESPIRATOR RESISTANCE TESTER
ITEM 003
BREATHING VALVE TIGHTNESS TESTER
ITEM 004
AXIAL TENSION TESTER FOR BREATHING BONNET
ITEM 005
AXIAL TENSION TESTER FOR BREATHING BONNET
ITEM 006
MASK FIELD TESTER
ITEM 007
HEADBAND TENSILE TESTING MACHINE
ITEM 008
JOINT PARTS&AXIAL TENSILE TESTING MACHINE
ITEM 009
MASK FLAME RETARDANT PERFORMANCE TESTER
ITEM 010
TEMPERATURE PRETREATMENT CONSTANT TEMPERATURE AND HUMIDITY CHAMBER
REFERENCE NUMBER: T-6336
MEDICAL DISPOSABLE PROTECTIVE CLOTHING TESTING INSTRUMENTS
ITEM 001
WATER PENETRATION RESISTANCE TESTER FOR PROTECTIVE CLOTHING
ITEM 002
MOISTURE PERMEABILITY TESTER FOR PROTECTIVE CLOTHING
ITEM 003
SURFACE MOISTURE RESISTANCE TESTER
ITEM 004
ANTISYNTHETIC BLOOD PENETRANT DETECTOR
ITEM 005
TENSILE TESTER FOR BREAKING STRENGTH AND ELONGATION
ITEM 006
FLAME RETARDANT PERFORMANCE TESTER FOR PROTECTIVE CLOTHING
ITEM 007
FRICTION ELECTRIFICATION TESTER FOR PROTECTIVE CLOTHING (FRENCH LADLE)
REFERENCE NUMBER: T-6337
DISPOSABLE MEDICAL RUBBER INSPECTION GLOVES TESTING INSTRUMENTS
ITEM 001
PLASTIC FILM THICKNESS TESTER
ITEM 002
RUBBER GLOVES TENSILE STRENGTH TESTER
ITEM 003
RUBBER GLOVES WATERPROOF TESTER
ITEM 004
RUBBER GLOVES PRETREATMENT AGING BOX
More information is available upon request.
E-mail us for price, pictures, video, or diagram.
Include our reference number -
M-5300 UNDER PAD PRODUCTION LINEREFERENCE NUMBER: M-5300 (131342BVGT12UF) L UNDER PAD PRODUCTION LINE UNDER PAD PRODUCTION LINE MODEL: 100CD PRODUCTS TO BE PRODUCED: 3 SIZES OF DISPOSABLE UNDER PAD (SIZE: 600x900mm, 600x600mm, 600x400mm) MECHANICAL DRIVING SYSTEM WITH INVERTER CONTROL PRODUCT STRUCTURE: FLUFF +SAP; TOP TISSUE; BOTTOM TISSUE; TOP SHEET; BACK SHEET QUANTITY AVAILABLE: 1 Learn More -
V-1816 AUTOMATIC RESPIRATOR REPLACEMENT FILTER MAKING MACHINEAUTOMATIC RESPIRATOR REPLACEMENT FILTER MAKING MACHINE IS ALSO CALLED A PARTICULATE RESPIRATOR FILTER MAKING MACHINE OR HALF FACE RESPIRATOR FILTER MAKING MACHINE, IT’S MADE UNDER MATURE TECHNOLOGY THAT SUPPORTS AUTOMATICALLY MATERIAL FEEDING, WELDING, PUNCHING AND CUTTING, REPLACEMENT FILTER FORMING, THIS MACHINE IS EASY TO OPERATE, BY CHANGING THE ROLLER, IT CAN PRODUCE DIFFERENT SHAPES OF FILTER. THIS MACHINE INCORPORATES ADVANCED ULTRASONIC WELDING AND EQUIPPED WITH CONSTANT TEMPERATURE CONTROLLER WHICH ENSURES THE FILTER FIRMLY AND CLEARLY WELDED.
FEATURES:
1. ADVANCED ULTRASONIC TECHNOLOGY WITH FIRM WELDING EFFECT, IT’S EQUIPPED WITH PULL AND PUSH TYPE MATERIAL FEEDING WHICH MAKES IT EASIER OPERATING.
2. THE MOLD (PATTERN ROLLER) CAN BE CUSTOMIZED TO PRODUCE DIFFERENT FILTERS.
3. THE WELDING LINE IS CLEAR AND FIRM.
ITEM NAME
TECHNICAL PARAMETERS
QTY
REMARK
SPECIFICATION
1800mm X 1200mm X 1800mm
1
HONGDA
WEIGHT
500KG
EFFICIENCY
20 TO 30PCS/MIN
VOLTAGE
220V/380V
AIR PRESSURE
3-6KG/CM²
FREQUENCY
15/20KHZ
POWER
4200W
MOLD SERVO MOTOR
SGM7G-09AFC61 4.4KW
1
YASKAWA
ULTRASONIC POWER SERVO MOTOR
SGM7G-13AFC61 1.3KW
2
YASKAWA
MATERIAL PULLING SERVO MOTOR
SGM7G-09AFC61 0.85KW
2
YASKAWA
MATERIAL FEEDING/CORRECTING/INDENTATION MOTOR
130BYG-350A
4
SONGYANG
POUCHING MOTOR
110BYG-350B
4
SONGYANG
110 STEPPER MOTOR
110BYG-350A
10
SONGYANG
UP AND LOWER MOTOR
90BYG-350A
2
SONGYANG
STEPPER MOTOR 56
SY57STH56-2004A
8
SONGYANG
DIRECT CURRENT MOTOR
0.4KW
2
DIRECT CURRENT MOTOR
0.6KW
1
ASYNCHRONOUS THREE-PHASE MOTOR
90S-6
1
0.75KW
FREQUENCY CONVERTER
AVF200-0152
1
1.5KW
MAIN PNEUMATIC COMPONENTS: AIRTAC (TAIWAN); MAIN ELECTRICAL COMPONENTS: PANASONIC (JAPAN), SICK (GERMANY), DONLIM (CHINA&JAPAN), ETC.
EMAIL US FOR PRICE & PICTURES
INCLUDE OUR REFERENCE NUMBER
Learn More -
M-5282 COSMETIC ROUND PADS PACKAGING MACHINE INTO BAGSREFERENCE NUMBER: M-5282 (1313121ANW12RX) L COSMETIC ROUND PADS PACKAGING MACHINE INTO BAGS NEW IN STOCK COSMETIC ROUND PADS PACKAGING MACHINE INTO BAGS FULLY AUTOMATIC MACHINE FOR PACKAGING ROUND PADS MADE OF COTTON OR SYNTHETIC FIBERS FOR COSMETIC USE IN DRAWSTRING BAGS AND BAGS WITH ZIPPER/ZIP-LOCK MADE OF PLASTIC MATERIAL. THE MACHINE REACHES THE MAXIMUM PERFORMANCE OF ABOUT 30 BAGS PER MINUTE. QUANTITY AVAILABLE: 1 Learn More -
YY-1140 RESPIRATORY RESISTANCE TESTER, FLOWMETER RANGE 0 L/MIN~100L/MIN, FLOWMETER RANGE ACCURACY ±2%YY-1140 RESPIRATORY RESISTANCE TESTER, FLOWMETER RANGE 0 L/MIN~100L/MIN, FLOWMETER RANGE ACCURACY ±2% DETAILS: THE RESPIRATORY RESISTANCE TESTER IS SUITABLE FOR DETERMINING THE INHALATION RESISTANCE AND EXHALATION RESISTANCE OF RESPIRATORS AND MASK PROTECTIVE PRODUCTS UNDER SPECIFIED CONDITIONS, AND FOR THE RELATED TESTING AND INSPECTION OF COMMON MASK PRODUCTS BY MANUFACTURERS OF NATIONAL LABOR PROTECTION ARTICLE INSPECTION AGENCIES. STANDARD: GB2626-2006,GB/T32610-2016. Learn More