Search results for: 'con'
- Related search terms
- conti
- Control+pan
- cont'[0]
- Conta
- conveyor-
- T-6552 MASK AIR TIGHTNESS TESTER
REFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
MASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 - V-1820 MASK AND RESPIRATOR FIELD TESTER
MAINLY USED FOR VISUAL FIELD TESTING OF MASKS AND RESPIRATORS, WHICH IS USEFUL FOR MASK AND RESPIRATOR MANUFACTURERS, QUALITY SUPERVISORS, SCIENTIFIC RESEARCH, AND FOR TESTING PRIOR TO SELLING MASKS.
FEATURES:
1. THE EQUIPMENT IS COMPOSED OF A SEMI-ARC BOW, RECORDING DEVICE, SEAT FRAME AND TEST HEAD DIE.
2. SEMI-ARC BOW: THE RADIUS IS 300 TO 340 mm
CAN BE ROTATED AROUND THE HORIZONTAL RADIUS PLANE PASSING THROUGH THE POINT 0°, AND A SCALE EXTENDING TO THE 90° ARC BOW EVERY 5° FROM 0° ON BOTH SIDES, EQUIPPED WITH SLIDING WHITE VISUAL STANDARD.
3. RECORDING DEVICE: THE RECORDING NEEDLE IS CONNECTED WITH THE VISUAL STANDARD THROUGH COMPONENTS SUCH AS AXLE WHEEL, AND THE DIRECTION AND ANGLE OF THE VISUAL STANDARD ARE RECORDED ON THE VISUAL FIELD DRAWING CORRESPONDINGLY.
4. SEAT FRAME: USED TO SUPPORT SEMI-CIRCULAR ARC BOW AND FIXED RECORDING DEVICE.
5. TEST THE HEAD MOLD: A STANDARD HEAD MOLD, THE TWO EYE HOLES OF THE HEAD MOLD ARE EQUIPPED WITH SMALL LIGHT BULBS, THE POSITION OF THE BULB AND THE POSITION OF THE HEAD MOLD ARE ACCORDING TO THE REQUIREMENTS OF GB 2890. THE TEST HEAD DIE MUST BE INSTALLED ON THE WORKBENCH IN SUCH A WAY THAT THE LEFT AND RIGHT EYES ARE PLACED AT THE CENTER OF THE SEMICIRCULAR ARCH AND THE "0" POINT IS DIRECTLY SEEN.MAIN INDICATORS
Learn More
1. SEMI-CIRCULAR ARC RADIUS: 335mm.
2. LEFT AND RIGHT FIELD OF VIEW: ≤120°.
3. BULB DISTANCE: THE VERTEX OF THE BULB IS CONNECTED AFTER THE TWO EYE POINTS (7±0.5).
APPLICABLE STANDARDS: GB/T 32610-2016, GB 2626-2019, GB2890-2009 - V-1817 SEMI-AUTOMATIC NOSE CLIP WELDING MACHINE
SEMI-AUTOMATIC NOSE CLIP WELDING MACHINE FOR NOSE CLIP WELDING FOR DUST MASK RESPIRATORS, IT’S EASY TO OPERATE, FIRM WELDING EFFECT. THIS MACHINE INCORPORATES CONSTANT TEMPERATURE WELDING, WHICH IS NOT HARMFUL TO THE FABRIC, IT’S THE IDEAL MACHINE FOR DUST MASK RESPIRATOR MANUFACTURING.
FEATURES:
1. THIS MACHINE IS EASY TO OPERATE; THE GLUED ALUMINUM NOSE CLIP IS MOVED BY PNEUMATIC THEN WELDED ONTO THE MASK.
2. IT’S HIGH PRECISION AND THE NOSE CLIP WELD IS FIRM.
3. WELDING WITH CONSTANT TEMPERATURE WHICH IS NOT HARMFUL TO THE FABRIC.
ITEM NAME
TECHNICAL PARAMTER
QTY
REMARK
SPECIFICATION
1200mm X 650mm X 1000mm
1
HONGDA
WEIGHT
50KG
EFFICIENCY
8 TO 15PCS/MIN
VOLTAGE
220V/380V
AIR PRESSURE
5KG/CM²
FREQUENCY
20KHZ
POWER
600W
MOLD SERVO MOTOR
SGM7G-09AFC61 4.4KW
1
YASKAWA
ULTRASONIC POWER SERVO MOTOR
SGM7G-13AFC61 1.3KW
2
YASKAWA
MATERIAL PULLING SERVO MOTOR
SGM7G-09AFC61 0.85KW
2
YASKAWA
MATERIAL FEEDING/CORRECTING/INDENTATION MOTOR
130BYG-350A
4
SONGYANG
POUCHING MOTOR
110BYG-350B
4
SONGYANG
110 STEPPER MOTOR
110BYG-350A
10
SONGYANG
UP AND LOWER MOTOR
90BYG-350A
2
SONGYANG
STEPPER MOTOR 56
SY57STH56-2004A
8
SONGYANG
DIRECT CURRENT MOTOR
0.4KW
2
DIRECT CURRENT MOTOR
0.6KW
1
ASYNCHRONOUS THREE-PHASE MOTOR
90S-6
1
0.75KW
FREQUENCY CONVERTER
AVF200-0152
1
1.5KW
MAIN PNEUMATIC COMPONENTS: AIRTAC(TAIWAN); MAIN ELECTRICAL COMPONENTS: PANASONIC(JAPAN), SICK(GERMANY), DONLIM(CHINA&JAPAN), ETC.
EMAIL US FOR PRICE & PICTURES
INCLUDE OUR REFERENCE NUMBER
- H-2366 MASK AND MEDICAL GOWN LABORATORY EQUIPMENT
REFERENCE NUMBER: T-6334
Learn More
ALL KINDS OF MASK TESTING INSTRUMENTS
(SURGICAL MASK)
(DISPOSABLE SURGICAL MASK)
(MEDICAL PROTECTIVE MASK)
(DAILY PROTECTIVE MASK)
ITEM 001
COMPREHENSIVE TENSION TESTER FOR SURGICAL MASK
ITEM 002
MASK SYNTHETIC BLOOD PENETRATION DETECTOR
ITEM 003
BACTERIAL PERCOLATION EFFICIENCY (BFE) TESTER
ITEM 004
PARTICLE EFFICIENCY (PFE) TESTER
ITEM 005
RESPIRATOR RESISTANCE TESTER
ITEM 006
MASK FLAME RETARDANT PERFORMANCE TESTER
ITEM 007
FABRIC SURFACE MOISTURE TESTER
ITEM 008
MASK AIR TIGHTNESS TESTER
ITEM 009
TEMPERATURE PRETREATMENT CONSTANT TEMPERATURE AND HUMIDITY CHAMBER
ITEM 010
COLOR FASTNESS TO FRICTION TESTER
ITEM 011
TEXTILE FORMALDEHYDE TESTER
ITEM 012
PH METER
REFERENCE NUMBER: T-6335
RESPIRATORY PROTECTIVE EQUIPMENT & SELF-IMBIBITION FILTER ANTI-PARTICULATE RESPIRATOR TESTING INSTRUMENTS
ITEM 001
FIITRATION EFFICIENCY N CLASS SODIUM CHLORIDE PARTICLES, P CLASS OIL PARTICLES
PARTICLE RATE EFFICIENCY TESTER
ITEM 002
RESPIRATOR RESISTANCE TESTER
ITEM 003
BREATHING VALVE TIGHTNESS TESTER
ITEM 004
AXIAL TENSION TESTER FOR BREATHING BONNET
ITEM 005
AXIAL TENSION TESTER FOR BREATHING BONNET
ITEM 006
MASK FIELD TESTER
ITEM 007
HEADBAND TENSILE TESTING MACHINE
ITEM 008
JOINT PARTS&AXIAL TENSILE TESTING MACHINE
ITEM 009
MASK FLAME RETARDANT PERFORMANCE TESTER
ITEM 010
TEMPERATURE PRETREATMENT CONSTANT TEMPERATURE AND HUMIDITY CHAMBER
REFERENCE NUMBER: T-6336
MEDICAL DISPOSABLE PROTECTIVE CLOTHING TESTING INSTRUMENTS
ITEM 001
WATER PENETRATION RESISTANCE TESTER FOR PROTECTIVE CLOTHING
ITEM 002
MOISTURE PERMEABILITY TESTER FOR PROTECTIVE CLOTHING
ITEM 003
SURFACE MOISTURE RESISTANCE TESTER
ITEM 004
ANTISYNTHETIC BLOOD PENETRANT DETECTOR
ITEM 005
TENSILE TESTER FOR BREAKING STRENGTH AND ELONGATION
ITEM 006
FLAME RETARDANT PERFORMANCE TESTER FOR PROTECTIVE CLOTHING
ITEM 007
FRICTION ELECTRIFICATION TESTER FOR PROTECTIVE CLOTHING (FRENCH LADLE)
REFERENCE NUMBER: T-6337
DISPOSABLE MEDICAL RUBBER INSPECTION GLOVES TESTING INSTRUMENTS
ITEM 001
PLASTIC FILM THICKNESS TESTER
ITEM 002
RUBBER GLOVES TENSILE STRENGTH TESTER
ITEM 003
RUBBER GLOVES WATERPROOF TESTER
ITEM 004
RUBBER GLOVES PRETREATMENT AGING BOX
More information is available upon request.
E-mail us for price, pictures, video, or diagram.
Include our reference number - M-6440 WARPING MACHINE FOR MEDICAL BANDAGE PLANT
REFERENCE NUMBER: M-6440
WARPING MACHINE FOR MEDICAL BANDAGE PLANT
WARPING MACHINE
ADJUST SPEED BY FREQUENCY CONVERTER, EASY TO ADJUST, SAVES ENERGY
TIGHT PRESS AUTOMATICALLY, PRESSURE IS ADJUSTABLE, EVEN WARPING
COUNT LENGTH AUTOMATICALLY, WARPING LENGTH CAN BE PRE-SET
COMB TYPE EXPANSION REED, OPEN IN TOP, EASY TO ROW LINE AND CONVENIENT TO ADJUST WIDTH
ON BOTH MACHINE HEAD AND CREEL OF YARNS, THERE ARE CONTROL DEVICES FOR STOPPING THE MACHINE WHEN THE YARN BREAKS, TO ENSURE THE MACHINE WILL STOP WHEN THE YARN BREAKS
WARPING SPEED: UP TO 350 METERS PER MINUTE
REMOTE CONTROL TO START AND STOP MACHINE AUTOMATICALLY, AVAILABLE DISTANCE 20M
AVAILABLE WARP ROLL: Ø300mm TO 410mm, INSIDE WARP BEAM LENGTH IS 255mm TO 260mm, IT CAN BE MADE ON CUSTOMERS’ DIFFERENT REQUESTS
MOTOR POWER: 1.5KW
ONE WARPING MACHINE CAN WORK FOR 20 BANDAGE WEAVING MACHINES
QUANTITY: 1
Learn More - M-5143 ROUND COTTON PAD MAKING MACHINEREFERENCE NUMBER: M-5143 (1212YJJGXX11) L ROUND COTTON PAD MAKING MACHINE NONWOVEN ROUND COTTON PAD MAKING MACHINE MODEL: RD MATERIAL WIDTH: 95CM; DIAMETER: 70CM SLITTING DEVICE: DERANGEMENT PERMUTATION ROUND MOULD PUNCHING EMBOSSING DEVICE: STEEL ROLL EMBOSSING, THE EMBOSSING PATTERN CAN BE CUSTOMIZED PRODUCT SIZE: CUSTOMIZED COUNTING WAY: LEFT AND RIGHT COUNTING SLITTING MATERIAL: COTTON, NONWOVEN, COTTON COMPOSITION MATERIAL PRODUCT FEATURE: EDGE OPEN OR NOT CONTROL SYSTEM: PLC SERVO CONTROL OF MOTOR SPEED MOTOR: SERVO MOTOR PARAMETER-SETTING: COLOR TOUCH SCREEN PRODUCTION SPEED: 400 PIECES PER MINUTE AIR COMPRESSOR: PROVIDED BY YOURSELF PACKING SIZE: DEPENDING ON THE CONFIGURATION POWER: 380V / 50HZ / 5.5KW WEIGHT: ABOUT 2300KG DEPENDING ON THE CONFIGURATION QUANTITY: 1 Learn More
- M-5142 MAKEUP REMOVING COTTON PAD PRODUCTION MACHINEREFERENCE NUMBER: M-5142 (1212QAZCXX11) L MAKEUP REMOVING COTTON PAD PRODUCTION MACHINE INSERTING STYLE MAKEUP REMOVING COTTON MACHINE MODEL: RE RAW MATERIAL WIDTH: 95CM; DIAMETER: 70CM SLITTING DEVICE: PUNCHING EMBOSSING DEVICE: HEAT EMBOSSING DEVICE PRODUCT SIZE: CUSTOMIZED COUNTING WAY: LEFT AND RIGHT COUNTING OUTPUTTING WAY: 2 BY 1 SLITTING MATERIAL: COTTON, NONWOVEN, COTTON COMPOSITION MATERIAL PRODUCT FEATURE: INSERTING STYLE COTTON PAD MACHINE CONTROL SYSTEM: FREQUENCY CONTROL OF MOTOR SPEED MOTOR: STEPPING MOTOR PARAMETER-SETTING: COLOR TOUCH SCREEN PRODUCTION SPEED: 600 PIECES PER MINUTE AIR COMPRESSOR: PROVIDED BY YOURSELF PACKING SIZE: DEPENDING ON THE CONFIGURATION POWER: 380V / 50HZ / 3.0KW WEIGHT: ABOUT 1500KG DEPENDING ON THE CONFIGURATION QUANTITY: 1 Learn More
- M-5141 COTTON PAD PRODUCTION MACHINEREFERENCE NUMBER: M-5141 (1212TTPCXX11) L COTTON PAD PRODUCTION MACHINE COTTON PAD SLICES CUTTING MACHINE MODEL: RC RAW MATERIAL WIDTH: 95CM; DIAMETER: 70CM SLITTING DEVICE: SHEAR TYPE ROUND KNIVES EMBOSSING DEVICE: STEEL ROLL EMBOSSING, THE PATTERN CAN BE CUSTOMIZED PRODUCT SIZE: WIDTH DEPENDS ON THE MOULD AND THE LENGTH CAN BE ADJUSTED WITHIN 10CM FREELY COUNTING WAY: LEFT AND RIGHT COUNTING SLITTING MATERIAL: COTTON, NONWOVEN, COTTON COMPOSITES PRODUCT FEATURE: EDGE OPEN OR NOT CONTROL SYSTEM: FREQUENCY CONTROL OF MOTOR SPEED MOTOR: STEPPING MOTOR PARAMETER-SETTING: MAN-MACHINE INTERFACE PRODUCTION SPEED: 300 TO 1600 PIECES PER MINUTE AIR COMPRESSOR: PROVIDED BY YOURSELF PACKING SIZE: DEPENDING ON THE CONFIGURATION POWER: 380V / 50HZ / 4.5KW WEIGHT: ABOUT 1800KG DEPENDING ON THE CONFIGURATION QUANTITY: 1 Learn More
- YY-1140 RESPIRATORY RESISTANCE TESTER, FLOWMETER RANGE 0 L/MIN~100L/MIN, FLOWMETER RANGE ACCURACY ±2%YY-1140 RESPIRATORY RESISTANCE TESTER, FLOWMETER RANGE 0 L/MIN~100L/MIN, FLOWMETER RANGE ACCURACY ±2% DETAILS: THE RESPIRATORY RESISTANCE TESTER IS SUITABLE FOR DETERMINING THE INHALATION RESISTANCE AND EXHALATION RESISTANCE OF RESPIRATORS AND MASK PROTECTIVE PRODUCTS UNDER SPECIFIED CONDITIONS, AND FOR THE RELATED TESTING AND INSPECTION OF COMMON MASK PRODUCTS BY MANUFACTURERS OF NATIONAL LABOR PROTECTION ARTICLE INSPECTION AGENCIES. STANDARD: GB2626-2006,GB/T32610-2016. Learn More
- T-7935 VASELINE PACKING MACHINET-7935 VASELINE PACKING MACHINE MACHINE SIZE: 5000mm (LENGTH) X 900mm (WIDTH) X 2000mm (HEIGHT) MACHINE WEIGHT: 2000KGS POWER: 9KW VOLTAGE: 380V PACKING: PE FILM Learn More