Search results for: 'Contro'
- Related search terms
- Control pa
- control pro
- Control+pan'
- Control+pa'"'
- Control pa'"'
-
Z-1613 AUTOMATIC CARTON PACKAGING MACHINEZ-1613 AUTOMATIC CARTON PACKAGING MACHINE CARTONING FORM: HORIZONTAL CARTONING CARTONING SPEED: 30 TO 40 BOXES PER MINUTE (DEPENDING ON CARTON DIMENSIONS) PROCESS REQUIREMENTS: -AUTOMATIC BOX OPENING, CARTONING -GLUE SPRAYING -BOX SEALING VOLTAGE: 220 VOLTS, 60Hz PLC MICRO COMPUTER FULL AUTOMATIC CONTROL MAN-MACHINE INTERFACE OPERATION SYSTEM (HMI), AUTOMATICALLY DISPLAYS THE PACKING SPEED, QUANTITY, FAULT REASON AND OTHER PERFORMANCE PARAMETERS. THE INDENTATION OF THE CARTON IS GENERALLY: 0.4mm DEEP QUANTITY: 1 Learn More -
VJ-1116 FULLY AUTOMATIC FLAT FACE MASK PRODUCTION LINE, 300 MASKS PER MINUTEVJ-1116 FULLY AUTOMATIC FLAT FACE MASK PRODUCTION LINE, 300 MASKS PER MINUTE MASK BODY PRODUCTION WITH AUTOMATIC FEEDING TO EAR LOOP WELDING FOR COMPLETE, AUTOMATED PRODUCTION MASK TYPE: SURGICAL, FLAT MASK WITH EAR LOOPS MASK DIMENSIONS: 175 x 95mm CAPACITY: 250 TO 300 PIECES PER MINUTE (FINISHED PRODUCT) NONWOVEN MATERIAL: SPUNBONDED AND MELT-BLOWN FABRIC QUANTITY: 1 Learn More -
FULLY AUTOMATIC MASK MACHINEREFERENCE NUMBER: P-8845 FULLY AUTOMATIC MASK MACHINE THIS EQUIPMENT IS A FULL-AUTOMATIC ONE-TIME PLANE MASK FORMING MACHINE, WHICH IS USED FOR THE FORMING OF ONE-TIME RECTANGULAR EAR HANGING THREE DRAWER MASKS. ONE MAIN MACHINE IS EQUIPPED WITH TWO EAR BELT SPOT WELDING MACHINES (ONE FOR TWO). THE DRIVING MOTOR IS SERVO MOTOR, SO IT HAS THE ADVANTAGES OF HIGH RELIABILITY, EASY OPERATION, ACCURATE TRANSMISSION, STABLE CONTROL, ADJUSTABLE SPEED, LOW COST AND CONVENIENT MAINTENANCE, ESPECIALLY SUITABLE FOR THE PRODUCTION OF HIGH-QUALITY MASKS. SPECIFICATIONS TEMPERATURE: 10 TO 350, HUMIDITY 5 TO 35%, NO FLAMMABILITY AND NONCORROSIVE GAS VOLTAGE: 220V POWER FREQUENCY: 50Hz PER 60Hz TOTAL POWER OF EQUIPMENT: 8.5KW ULTRASONIC FREQUENCY: 5 TO 20KHz MAX FEEDING WITH OVERALL DIMENSION OF EQUIPMENT: 6100 x 3300 x 1800 MACHINE WEIGHT: 2 TONS PRODUCTION EFFICIENCY: 80 TO 120 TABLETS PER MIN (EACH WORKING STATION 60 PCS PER MIN, AS WE HAVE TWO WORKING STATION). OPERATOR: 1 PERSON QUANTITY: 1 Learn More -
T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENTREFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More -
T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASKREFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More -
T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More -
T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTERREFERENCE NUMBER: T-6550
MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
TECHNICAL SPECIFICATIONS AND CONFIGURATION:
1. THE INSTRUMENT ADOPTS AN AIR SOURCE THAT CAN PROVIDE (0.5 ~ 30±0.1) KPA PRESSURE TO CONTINUOUSLY PRESSURIZED THE SAMPLE, WHICH IS NOT RESTRICTED BY THE SPACE OF THE TEST SITE;
2. THE AIR PRESSURE RANGE CAN BE ADJUSTED FREELY, AND THE ADJUSTMENT RANGE (0.5 ~ 30) KPA;
3. COLOR TOUCH SCREEN DISPLAY AND OPERATION;
4. THE SAMPLE CLAMPING PAD IS PROCESSED WITH IMPORTED SPECIAL ALUMINUM PROFILES, WHICH IS LIGHT IN MATERIAL, CLEAN IN SURFACE AND NEVER RUSTS.
5. THE INSTRUMENT ADOPTS IMPORTED SPECIAL ALUMINUM WIRE DRAWING PANEL, EQUIPPED WITH METAL KEYS, SENSITIVE OPERATION, NOT EASY TO DAMAGE;
6. CLAMPING DEVICE FOR INSTRUMENT SAMPLES, EQUIPPED WITH LOCKING PROTECTION, TO PREVENT THE SYNTHETIC BLOOD FROM SPLASHING AROUND;
7. CLAMPING FORCE IS ACCURATE AND RELIABLE;
8. THE TEST TANK IS EQUIPPED WITH A SPECIAL PLACEMENT DEVICE, WHICH IS CONVENIENT FOR CUSTOMERS TO OPERATE;
9. THE TEST TANK IS PROCESSED WITH SPECIAL 316 STAINLESS STEEL, AND THE TOP IS EQUIPPED WITH A SPECIAL COVER FOR HIGH TRANSPARENT PROTECTION;
10. THE WASHER BELOW THE SAMPLE IS MADE OF HIGH-QUALITY PTFE MATERIAL AFTER SPECIAL PROCESSING;
11. SQUARE METAL BLOCK NET: OPEN SPACE ≥50°%; BENDING ≤5mm AT 30KPA;
12. INSTRUMENT TIME CONTROL ACCURACY ≤01 SECONDS;
13. THE SHELL OF THE INSTRUMENT IS MADE OF HIGH-QUALITY METAL BAKING PAINT, WHICH IS BEAUTIFUL AND GENEROUS.
14. EQUIPPED WITH PRINTER INTERFACE, CONNECTED TO THE PRINTER CAN DIRECTLY PRINT DATA REPORTS.
TECHNICAL PARAMETERS:
1. SAMPLE SIZE: 75mm X 75mm
2. TEST AREA: 28.26 SQUARE CENTIMETERS
3. AIR PRESSURE ADJUSTMENT RANGE (0.5 ~ 30) KPA
4. EXTERNAL SIZE: 500mm X 500mm X 500mm (L X W X H)
5. WEIGHT OF THE INSTRUMENT: 40 KG
6. POWER SUPPLY: AC220V, 50HZ,SCOPE OF SUPPLY: 1. ONE MAIN MACHINE; 2. TWO PTFE GASKETS; 3. TWO ORDINARY WASHERS; 4. ONE METAL BLOCKING NET; 5. A SET OF SPECIAL LOCKING TOOLS; 6. ONE HIGH-QUALITY SILENT AIR PUMP, [NOTE: SAFETY PRODUCTION LICENSE IS NOT INCLUDED]. 7. EQUIPPED WITH PRINTER INTERFACE; 8. ONE SAMPLE TEMPLATE; 9. ONE PRODUCT CERTIFICATE; 10. ONE COPY OF PRODUCT OPERATION MANUAL.
OPERATION INSTRUCTION:
INSERT THE AIR PUMP OUTPUT PIPE INTO THE OIL AND WATER SEPARATOR OF THE INSTRUMENT AS REQUIRED (PRESSURE 0.1-0.3MPA).
AFTER SWITCHING ON THE POWER, THE STARTUP INTERFACE (NAME OF THE DEVICE) IS DISPLAYED.
PRESS THE "ENTER" BUTTON TO ENTER THE TEST INTERFACE, AS SHOWN IN THE FOLLOWING FIGURE:
CLICK "SETTING” BUTTON, GET INTO PARAMETER SETTING SCREEN, AS BELOW THIS SCREEN CAN SET THE SYSTEM TIME, DATE AND TESTING TIME, AFTER SETTING, CLICK "SAVE” BUTTON TO KEEP THE SETTING DATA. (NOTE: IT REQUIRES 5 MINUTES IN THE STANDARD)
QUANTITY: 1
Learn More -
T-6581 MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUITREFERENCE NUMBER: T-6581
MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT
MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT
MEETS GB19082-2009
EN14126 TESTING STANDARD
CAPACITY 100,000 PIECES/DAY(CAPACITY CAN BE ENLARGEDACCORDING TO THE ORDER)
PRODUCTION CAPACITY IS EXPANDING
LARGE QUANTITY IS PREFERRED
THE PAYMENT METHOD IS 100% IN ADVANCE
NOTE: IN THE MASS PRODUCTION OF PROTECTIVE CLOTHING, THE GOVERNMENT, HOSPITALS, AND DISEASE CONTROL CENTERS HAVE PRIORITY IN PURCHASING
MATERIAL: MADE OF 65GWHITE COMPOSITE FILM + 30G NONWOVEN FABRIC + 25G FILM + 3G GLUE + 2.0CM EVA 0.12MMSEALED LINE, TWO PARTS OF PROTECTIVE CLOTHING, HOODEDTOTAL WEIGHT OF CLOTHING IS ABOUT 330-350 G
ONLY HOSPITAL ICU REQUIRED STERILE TYPE, ALL OTHER PLACESREQUIRED NON-STERILE TYPEPACKAGE: MEDICAL PROTECTIVE CLOTHING
CARTON OUTER BOX SIZE: 560 X360 X400mm
SINGLE BOX WEIGHT: 13.5 KG(VOLUME WEIGHT:16.5 KG)45 PIECES PER BOX
MINIMUM ORDER QUANTITY: 10,000 PIECES
Learn More -
J-2811 AIRBORNE PARTICLE COUNTERAIRBORNE PARTICLE COUNTER
PORTABLE PARTICLE COUNTER WITH 0.10 MICRON SENSITITIVITY AND 1.0 CFM (28.3 LPM) FLOW RATE USING LONG LIFE LASER DIODE TECHNOLOGY.
DESIGNED TO OPERATE IN ISO CLASS 1 TO CLASS 7 CLEANROOMS WITHOUT CONCERNS OF IT DEGRADING ITS ENVIRONMENT OR EXCEEDING CONCENTRATION LIMITS
USES AN OPTICS AND PHOTODIODE SYSTEM DESIGNED TO REDUCE OR ELIMINATE THE TEMPERATURE ISSUES ASSOCIATED WITH HIGH POWER LASER DIODE SENSORS
WITH THERMALLY CONTROLLED EXHAUST SYSTEM AND HEPA FILTER OPTION TO PREVENT ANY EXTERNAL CONTAMINATIONFEATURES
0.1- 1.0 µm SENSITIVITY
1.0 CFM (28.3 LPM)
UP TO 8 CHANNELS OF SIMULTANEOUS COUNT DATA
21 CFR PART 11 COMPLIANT SECURE USB FLASH TRANSFER
LASER DIODE SENSOR TECHNOLOGY
5.7 INCH COLOR TOUCH SCREEN DISPLAY
THERMAL PRINTER
STAINLESS STEEL CONSTRUCTION
ETHERNET/RS485/MODBUS, 4X 4-20MA ANALOG OUTPUTS
3,000 RECORD DATA STORAGE
50-RECORD CONFIGURABLE RECIPE DATABASE
Report wizard: ISO-14644-1, EU GMP Annex 1, FS-209ESTANDARD CHANNEL SIZES: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0 µm
INCLUDES
OPERATING MANUAL ON CD; ISOKINETIC SAMPLE PROBE WITH TRIPOD AND TUBING; PURGE FILTER; POWER CABLE AND SPARE FUSE; LMS XCHANGE AND EXPRESS SOFTWARE; PRINTER; PRINTER PAPERQUANTITY: 1
Learn More -
T-6575 NON-INVASIVE VENTILATORNON-INVASIVE VENTILATOR
Learn More
CERTIFICATE: CE
MEDICAL VENTILATOR
TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
VENTILATOR TYPE: ELECTRIC CONTROL
SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
*VENTILATION MODE: CPAP, S, S/T, T
PRESSURE RANGE:
PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
PRESSURE ACCURACY: + 0.5CMH2O
PARAMETER SETTING:
DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
INSPIRATORY PHASE PRESSURE: 4-30CMH2O
EXPIRATORY PRESSURE: 4-30CMH2O
EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
INSPIRATORY SENSITIVITY: 1-8 STALLS
EXPIRATORY SENSITIVITY: 1-8 STALLS
RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
INSPIRATORY TIME: 0.3-3.0S
BACKUP RATE: ON / OFF, DEFAULT 10
PRESSURE RISE TIME: 1-4 STALLS
HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
*TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
*DATA MANAGEMENT:
NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
PARTS:
SD CARD: STANDARD
SD CARD SLOT: STANDARD
PIPING: 9 22MM, 1.8M LONG
FACE SHIELD: F2 NOSE MASK AS STANDARD
NOISE: LESS THAN 30DB
ENVIRONMENT CONDITION:
TEMPERATURE:
(WHEN USED) 5 -35 C
(DURING TRANSPORTATION AND STORAGE) -20 C -55 C
ATMOSPHERIC PRESSURE:
(WHEN USED) 760-1060HPA
(DURING TRANSPORTATION AND STORAGE) 760-1060HPA
WORKING HOURS: MORE THAN 8 HOURS
POWER SUPPLY REQUIREMENTS:
AC VOLTAGE: 100-240V
FREQUENCY: 50HZ/60HZ
INPUT POWER: LESS THAN 2A
WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
INSTRUMENT SIZE: 290mm X 180mm X 134mm
WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
ITEM 001
QUANTITY: 10 SETS-999 SETS
ITEM 002
QUANTITY: 1,000 SETS-9,999SETS
ITEM 003
QUANTITY: ≥10,000 SETS