- T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
REFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More - T-6551 MASK FLAME RETARDANT PERFORMANCE TESTER
REFERENCE NUMBER: T-6551
MASK FLAME RETARDANT PERFORMANCE TESTER
MASK FLAME RETARDANT PERFORMANCE TESTER
TECHNICAL INDEX:
1.THE LINEAR VELOCITY OF THE NOSE TIP OF THE DIE IS (60 ± 5) MM / S
2.THE DIAMETER OF FLAME TEMPERATURE MEASURINGPROBE IS 1.5MM
3.THE FLAME TEMPERATURE IS (800 ± 50) °C
4.THE DISTANCE BETWEEN THE BURNER TOP AND THE MASK IS (20 ± 2) MM
5.METAL DIE
APPLICABLE STANDARD:
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
YY 0469-2011 MEDICAL SURGICAL MASK
MEDICAL PROTECTIVE MASK REFERS TO A SELF-PRIMING FILTER TYPE DUST-PROOF MEDICAL PROTECTIVE MASK THAT CAN FILTER THE PARTICLES IN THE AIR AND BLOCK THE DROPLETS, BLOOD, BODY FLUIDS, SECRETIONS, ETC.
QUANTITY: 1
Learn More - T-6552 MASK AIR TIGHTNESS TESTER
REFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
MASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 - T-6581 MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT
REFERENCE NUMBER: T-6581
MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT
MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT
MEETS GB19082-2009
EN14126 TESTING STANDARD
CAPACITY 100,000 PIECES/DAY(CAPACITY CAN BE ENLARGEDACCORDING TO THE ORDER)
PRODUCTION CAPACITY IS EXPANDING
LARGE QUANTITY IS PREFERRED
THE PAYMENT METHOD IS 100% IN ADVANCE
NOTE: IN THE MASS PRODUCTION OF PROTECTIVE CLOTHING, THE GOVERNMENT, HOSPITALS, AND DISEASE CONTROL CENTERS HAVE PRIORITY IN PURCHASING
MATERIAL: MADE OF 65GWHITE COMPOSITE FILM + 30G NONWOVEN FABRIC + 25G FILM + 3G GLUE + 2.0CM EVA 0.12MMSEALED LINE, TWO PARTS OF PROTECTIVE CLOTHING, HOODEDTOTAL WEIGHT OF CLOTHING IS ABOUT 330-350 G
ONLY HOSPITAL ICU REQUIRED STERILE TYPE, ALL OTHER PLACESREQUIRED NON-STERILE TYPEPACKAGE: MEDICAL PROTECTIVE CLOTHING
CARTON OUTER BOX SIZE: 560 X360 X400mm
SINGLE BOX WEIGHT: 13.5 KG(VOLUME WEIGHT:16.5 KG)45 PIECES PER BOX
MINIMUM ORDER QUANTITY: 10,000 PIECES
Learn More - J-2813 HANDHELD AIRBORNE PARTICLE COUNTER, MODEL 3000
FEATURES
0.3 - 25 µm SENSITIVITY
FLOW RATE: 1.0 CFM (28.3 LPM)
UP TO 8 CHANNELS OF SIMULTANEOUS COUNT DATA
21 CFR PART 11 COMPLIANT SECURE USB FLASH TRANSFER
EXTREME LIFE LASER DIODE TECHNOLOGY >20-YEAR MTTF
5.7 INCH COLOR TOUCH SCREEN DISPLAY
THERMAL PRINTER
STAINLESS STEEL CONSTRUCTION
ETHERNET/RS485/MODBUS, 4x 4-20mA ANALOG INPUTS
3,000 RECORD DATA STORAGE
50-RECORD CONFIGURABLE RECIPE DATABASE
REPORT WIZARD: FS-209E, ISO-14644-1 & EU GMP ANNEX 1
2 YEAR WARRANTYSTANDARD 6 CHANNELS: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm , 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 µm
STANDARD 8 CHANNELS: 0.3,0.5,0.7,1.0,3.0,5.0,7.0,10.0 µm
OPTIONAL 8 CHANNELS: OPTIONAL BETWEEN 0.3 AND 25.0 µm
COUNTING EFFICIENCY: 50%@0.3µm; 100% FOR PARTICLES > 0.45 µm (PER ISO 21501-4)
CONCETRATION LIMITS: 1,000,000 PARTICLES/FT3, (35,300,000/M3) @ 10% COINCIDENCE LOSS SUITABLE FOR ISO CLASSES 1-8 CLEANROOMS
DIMENSIONS: 9.5”(L) x 8.0”(W) x 10.2”(H) (24.13 x 20.32 x 25.9 cm)
WEIGHT: WITH BATTERY: 13.95 LBS (6.33 KG), WITHOUT BATTERY 12.35 LBS (5.6 KG)INCLUDES
OPERATING MANUAL WITH CD, LMS EXPRESS TRANSFER SOFTWARE DOWNLOAD INSTRUCTIONS, ISOKINETIC SAMPLE PROBE, TRIPOD, TUBING, PURGE FILTER, POWER CABLES, SPARE FUSE, PRINTER, PRINTER PAPERLEAD TIME: 1 TO 2 WEEKS FROM RECEIPT OF ORDER
QUANTITY: 1
Learn More - J-2812 HANDHELD PARTICLE COUNTER
0.2 µm - 2 µm
0.1 CFM (2.83LPM) Flow Rate
View 6 Particle Sizes Simultaneously
-STANDARD 6 CHANNELS: 0.2, 0.3, 0.5, 0.7, 1.0, 2.0 µm
COUNTING EFFICIENCY: 50%@0.2µm;100% FOR PARTICLES >0.3 µm (per ISO 21501-4)
DESIGNED FOR ISO 21501-4 COMPLIANCE: UNIT-TO-UNIT ACCURACY AND REPEATABILITY
BRIGHT 3.5"(8.89 cm) COLOR TOUCH SCREEN DISPLAY
REMOVABLE / RECHARGEABLE LI-ION BATTERY
LARGE MEMORY FOR STORING DATA (3,000 SAMPLES)
CONCENTRATION LIMIT - 4,000,000 / ft3
TEMPERATURE / RELATIVE HUMIDITY PROBE INCLUDED
ALPHANUMERIC LOCATION LABELS
TEST WIZARD FOR CLEANROOM PASS / FAIL REPORTS: FS-209E, ISO 14644-1 OR EU GMP ANNEX 1
EASILY CONFIGURABLE INTERFACE WITH ZOOM CAPABILITY
INTERNAL AUDIBLE ALARM
ERGONOMICALLY DESIGNED
LIGHTWEIGHT
OPEN ARCHITECTURE CONNECTIVITY WITH OPC SERVERINCLUDES
OPERATING MANUAL ON CD, REMOVABLE BATTERY, DIRECT MOUNT INSOKINETIC SAMPLE PROBE, PURGE FILTER, TEMPERATURE/RELATIVE HUMITIY PROBE, POWER SUPPLY, POWER CORD, LMS EXPRESS SOFTWARELEAD TIME: SOMETIME IN MAY 2020
QUANTITY: 1
Learn More - J-2811 AIRBORNE PARTICLE COUNTER
AIRBORNE PARTICLE COUNTER
PORTABLE PARTICLE COUNTER WITH 0.10 MICRON SENSITITIVITY AND 1.0 CFM (28.3 LPM) FLOW RATE USING LONG LIFE LASER DIODE TECHNOLOGY.
DESIGNED TO OPERATE IN ISO CLASS 1 TO CLASS 7 CLEANROOMS WITHOUT CONCERNS OF IT DEGRADING ITS ENVIRONMENT OR EXCEEDING CONCENTRATION LIMITS
USES AN OPTICS AND PHOTODIODE SYSTEM DESIGNED TO REDUCE OR ELIMINATE THE TEMPERATURE ISSUES ASSOCIATED WITH HIGH POWER LASER DIODE SENSORS
WITH THERMALLY CONTROLLED EXHAUST SYSTEM AND HEPA FILTER OPTION TO PREVENT ANY EXTERNAL CONTAMINATIONFEATURES
0.1- 1.0 µm SENSITIVITY
1.0 CFM (28.3 LPM)
UP TO 8 CHANNELS OF SIMULTANEOUS COUNT DATA
21 CFR PART 11 COMPLIANT SECURE USB FLASH TRANSFER
LASER DIODE SENSOR TECHNOLOGY
5.7 INCH COLOR TOUCH SCREEN DISPLAY
THERMAL PRINTER
STAINLESS STEEL CONSTRUCTION
ETHERNET/RS485/MODBUS, 4X 4-20MA ANALOG OUTPUTS
3,000 RECORD DATA STORAGE
50-RECORD CONFIGURABLE RECIPE DATABASE
Report wizard: ISO-14644-1, EU GMP Annex 1, FS-209ESTANDARD CHANNEL SIZES: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0 µm
INCLUDES
OPERATING MANUAL ON CD; ISOKINETIC SAMPLE PROBE WITH TRIPOD AND TUBING; PURGE FILTER; POWER CABLE AND SPARE FUSE; LMS XCHANGE AND EXPRESS SOFTWARE; PRINTER; PRINTER PAPERQUANTITY: 1
Learn More - V-1819 KN95 MASKS AVAILABLE FOR SALE, CE CERTIFIED
STANDARD: GB2626-2006 KN95
0.3 MICRON PARTICULATE FILTERING > 95%
BUILT-IN ADJUSTABLE SOFT NOSE CLIP
4 LAYERS (4 PLY) IS AVAILABLE NOW
3 LAYERS (3 PLY) CAN ALSO BE MADE
ALL MASKS PASSED CE CERTIFICATIONQUANTITY:
Learn More
4 MASKS PER BAG
160 BAGS PER CARTON = 640 MASKS PER CARTON
350 CARTONS IN A 20 FOOT CONTAINER= 224,000 MASKS PER CONTAINER
WEIGHT AND DIMENSIONS OF ONE CARTON:
GROSS WEIGHT: 5.485 KG
DIMENSIONS: 520mm x 320mm x 480mm - H-2366 MASK AND MEDICAL GOWN LABORATORY EQUIPMENT
REFERENCE NUMBER: T-6334
Learn More
ALL KINDS OF MASK TESTING INSTRUMENTS
(SURGICAL MASK)
(DISPOSABLE SURGICAL MASK)
(MEDICAL PROTECTIVE MASK)
(DAILY PROTECTIVE MASK)
ITEM 001
COMPREHENSIVE TENSION TESTER FOR SURGICAL MASK
ITEM 002
MASK SYNTHETIC BLOOD PENETRATION DETECTOR
ITEM 003
BACTERIAL PERCOLATION EFFICIENCY (BFE) TESTER
ITEM 004
PARTICLE EFFICIENCY (PFE) TESTER
ITEM 005
RESPIRATOR RESISTANCE TESTER
ITEM 006
MASK FLAME RETARDANT PERFORMANCE TESTER
ITEM 007
FABRIC SURFACE MOISTURE TESTER
ITEM 008
MASK AIR TIGHTNESS TESTER
ITEM 009
TEMPERATURE PRETREATMENT CONSTANT TEMPERATURE AND HUMIDITY CHAMBER
ITEM 010
COLOR FASTNESS TO FRICTION TESTER
ITEM 011
TEXTILE FORMALDEHYDE TESTER
ITEM 012
PH METER
REFERENCE NUMBER: T-6335
RESPIRATORY PROTECTIVE EQUIPMENT & SELF-IMBIBITION FILTER ANTI-PARTICULATE RESPIRATOR TESTING INSTRUMENTS
ITEM 001
FIITRATION EFFICIENCY N CLASS SODIUM CHLORIDE PARTICLES, P CLASS OIL PARTICLES
PARTICLE RATE EFFICIENCY TESTER
ITEM 002
RESPIRATOR RESISTANCE TESTER
ITEM 003
BREATHING VALVE TIGHTNESS TESTER
ITEM 004
AXIAL TENSION TESTER FOR BREATHING BONNET
ITEM 005
AXIAL TENSION TESTER FOR BREATHING BONNET
ITEM 006
MASK FIELD TESTER
ITEM 007
HEADBAND TENSILE TESTING MACHINE
ITEM 008
JOINT PARTS&AXIAL TENSILE TESTING MACHINE
ITEM 009
MASK FLAME RETARDANT PERFORMANCE TESTER
ITEM 010
TEMPERATURE PRETREATMENT CONSTANT TEMPERATURE AND HUMIDITY CHAMBER
REFERENCE NUMBER: T-6336
MEDICAL DISPOSABLE PROTECTIVE CLOTHING TESTING INSTRUMENTS
ITEM 001
WATER PENETRATION RESISTANCE TESTER FOR PROTECTIVE CLOTHING
ITEM 002
MOISTURE PERMEABILITY TESTER FOR PROTECTIVE CLOTHING
ITEM 003
SURFACE MOISTURE RESISTANCE TESTER
ITEM 004
ANTISYNTHETIC BLOOD PENETRANT DETECTOR
ITEM 005
TENSILE TESTER FOR BREAKING STRENGTH AND ELONGATION
ITEM 006
FLAME RETARDANT PERFORMANCE TESTER FOR PROTECTIVE CLOTHING
ITEM 007
FRICTION ELECTRIFICATION TESTER FOR PROTECTIVE CLOTHING (FRENCH LADLE)
REFERENCE NUMBER: T-6337
DISPOSABLE MEDICAL RUBBER INSPECTION GLOVES TESTING INSTRUMENTS
ITEM 001
PLASTIC FILM THICKNESS TESTER
ITEM 002
RUBBER GLOVES TENSILE STRENGTH TESTER
ITEM 003
RUBBER GLOVES WATERPROOF TESTER
ITEM 004
RUBBER GLOVES PRETREATMENT AGING BOX
More information is available upon request.
E-mail us for price, pictures, video, or diagram.
Include our reference number - M-5148 COTTON PAD MAKING MACHINEREFERENCE NUMBER: M-5148 (121215HNF11U) L COTTON PAD MAKING MACHINE MODEL: YM-01 BREADTH: 1020mm FEEDING FORM: MECHANICAL FREQUENCY CONTROL & TWICE-WEIGHING WEIGHT UNEVENNESS FOR FEEDING: 0.7% ~ 1.7% APPLICABLE FIBER LENGTH: 24 TO 75mm DRAFT MULTIPLE 6 7.3~120.2 OUTPUT PER MACHINE HOUR: 5~25KG TOTAL POWER OF MOTORS: 7.37KG TOTAL WEIGHT OF THE MACHINE: APPROXIMATELY 7.5 TONS TOTAL FLOOR SPACE (LxW): 7500mm x 2000mm QUANTITY AVAILABLE: 1 Learn More