Search results for: 'control+p'
- Related search terms
- Control+pa
- control+prog
- control+programs
- control+pin'
- Control+pa'||'
-
T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More -
T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTERREFERENCE NUMBER: T-6550
MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
TECHNICAL SPECIFICATIONS AND CONFIGURATION:
1. THE INSTRUMENT ADOPTS AN AIR SOURCE THAT CAN PROVIDE (0.5 ~ 30±0.1) KPA PRESSURE TO CONTINUOUSLY PRESSURIZED THE SAMPLE, WHICH IS NOT RESTRICTED BY THE SPACE OF THE TEST SITE;
2. THE AIR PRESSURE RANGE CAN BE ADJUSTED FREELY, AND THE ADJUSTMENT RANGE (0.5 ~ 30) KPA;
3. COLOR TOUCH SCREEN DISPLAY AND OPERATION;
4. THE SAMPLE CLAMPING PAD IS PROCESSED WITH IMPORTED SPECIAL ALUMINUM PROFILES, WHICH IS LIGHT IN MATERIAL, CLEAN IN SURFACE AND NEVER RUSTS.
5. THE INSTRUMENT ADOPTS IMPORTED SPECIAL ALUMINUM WIRE DRAWING PANEL, EQUIPPED WITH METAL KEYS, SENSITIVE OPERATION, NOT EASY TO DAMAGE;
6. CLAMPING DEVICE FOR INSTRUMENT SAMPLES, EQUIPPED WITH LOCKING PROTECTION, TO PREVENT THE SYNTHETIC BLOOD FROM SPLASHING AROUND;
7. CLAMPING FORCE IS ACCURATE AND RELIABLE;
8. THE TEST TANK IS EQUIPPED WITH A SPECIAL PLACEMENT DEVICE, WHICH IS CONVENIENT FOR CUSTOMERS TO OPERATE;
9. THE TEST TANK IS PROCESSED WITH SPECIAL 316 STAINLESS STEEL, AND THE TOP IS EQUIPPED WITH A SPECIAL COVER FOR HIGH TRANSPARENT PROTECTION;
10. THE WASHER BELOW THE SAMPLE IS MADE OF HIGH-QUALITY PTFE MATERIAL AFTER SPECIAL PROCESSING;
11. SQUARE METAL BLOCK NET: OPEN SPACE ≥50°%; BENDING ≤5mm AT 30KPA;
12. INSTRUMENT TIME CONTROL ACCURACY ≤01 SECONDS;
13. THE SHELL OF THE INSTRUMENT IS MADE OF HIGH-QUALITY METAL BAKING PAINT, WHICH IS BEAUTIFUL AND GENEROUS.
14. EQUIPPED WITH PRINTER INTERFACE, CONNECTED TO THE PRINTER CAN DIRECTLY PRINT DATA REPORTS.
TECHNICAL PARAMETERS:
1. SAMPLE SIZE: 75mm X 75mm
2. TEST AREA: 28.26 SQUARE CENTIMETERS
3. AIR PRESSURE ADJUSTMENT RANGE (0.5 ~ 30) KPA
4. EXTERNAL SIZE: 500mm X 500mm X 500mm (L X W X H)
5. WEIGHT OF THE INSTRUMENT: 40 KG
6. POWER SUPPLY: AC220V, 50HZ,SCOPE OF SUPPLY: 1. ONE MAIN MACHINE; 2. TWO PTFE GASKETS; 3. TWO ORDINARY WASHERS; 4. ONE METAL BLOCKING NET; 5. A SET OF SPECIAL LOCKING TOOLS; 6. ONE HIGH-QUALITY SILENT AIR PUMP, [NOTE: SAFETY PRODUCTION LICENSE IS NOT INCLUDED]. 7. EQUIPPED WITH PRINTER INTERFACE; 8. ONE SAMPLE TEMPLATE; 9. ONE PRODUCT CERTIFICATE; 10. ONE COPY OF PRODUCT OPERATION MANUAL.
OPERATION INSTRUCTION:
INSERT THE AIR PUMP OUTPUT PIPE INTO THE OIL AND WATER SEPARATOR OF THE INSTRUMENT AS REQUIRED (PRESSURE 0.1-0.3MPA).
AFTER SWITCHING ON THE POWER, THE STARTUP INTERFACE (NAME OF THE DEVICE) IS DISPLAYED.
PRESS THE "ENTER" BUTTON TO ENTER THE TEST INTERFACE, AS SHOWN IN THE FOLLOWING FIGURE:
CLICK "SETTING” BUTTON, GET INTO PARAMETER SETTING SCREEN, AS BELOW THIS SCREEN CAN SET THE SYSTEM TIME, DATE AND TESTING TIME, AFTER SETTING, CLICK "SAVE” BUTTON TO KEEP THE SETTING DATA. (NOTE: IT REQUIRES 5 MINUTES IN THE STANDARD)
QUANTITY: 1
Learn More -
T-6581 MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUITREFERENCE NUMBER: T-6581
MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT
MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT
MEETS GB19082-2009
EN14126 TESTING STANDARD
CAPACITY 100,000 PIECES/DAY(CAPACITY CAN BE ENLARGEDACCORDING TO THE ORDER)
PRODUCTION CAPACITY IS EXPANDING
LARGE QUANTITY IS PREFERRED
THE PAYMENT METHOD IS 100% IN ADVANCE
NOTE: IN THE MASS PRODUCTION OF PROTECTIVE CLOTHING, THE GOVERNMENT, HOSPITALS, AND DISEASE CONTROL CENTERS HAVE PRIORITY IN PURCHASING
MATERIAL: MADE OF 65GWHITE COMPOSITE FILM + 30G NONWOVEN FABRIC + 25G FILM + 3G GLUE + 2.0CM EVA 0.12MMSEALED LINE, TWO PARTS OF PROTECTIVE CLOTHING, HOODEDTOTAL WEIGHT OF CLOTHING IS ABOUT 330-350 G
ONLY HOSPITAL ICU REQUIRED STERILE TYPE, ALL OTHER PLACESREQUIRED NON-STERILE TYPEPACKAGE: MEDICAL PROTECTIVE CLOTHING
CARTON OUTER BOX SIZE: 560 X360 X400mm
SINGLE BOX WEIGHT: 13.5 KG(VOLUME WEIGHT:16.5 KG)45 PIECES PER BOX
MINIMUM ORDER QUANTITY: 10,000 PIECES
Learn More -
J-2811 AIRBORNE PARTICLE COUNTERAIRBORNE PARTICLE COUNTER
PORTABLE PARTICLE COUNTER WITH 0.10 MICRON SENSITITIVITY AND 1.0 CFM (28.3 LPM) FLOW RATE USING LONG LIFE LASER DIODE TECHNOLOGY.
DESIGNED TO OPERATE IN ISO CLASS 1 TO CLASS 7 CLEANROOMS WITHOUT CONCERNS OF IT DEGRADING ITS ENVIRONMENT OR EXCEEDING CONCENTRATION LIMITS
USES AN OPTICS AND PHOTODIODE SYSTEM DESIGNED TO REDUCE OR ELIMINATE THE TEMPERATURE ISSUES ASSOCIATED WITH HIGH POWER LASER DIODE SENSORS
WITH THERMALLY CONTROLLED EXHAUST SYSTEM AND HEPA FILTER OPTION TO PREVENT ANY EXTERNAL CONTAMINATIONFEATURES
0.1- 1.0 µm SENSITIVITY
1.0 CFM (28.3 LPM)
UP TO 8 CHANNELS OF SIMULTANEOUS COUNT DATA
21 CFR PART 11 COMPLIANT SECURE USB FLASH TRANSFER
LASER DIODE SENSOR TECHNOLOGY
5.7 INCH COLOR TOUCH SCREEN DISPLAY
THERMAL PRINTER
STAINLESS STEEL CONSTRUCTION
ETHERNET/RS485/MODBUS, 4X 4-20MA ANALOG OUTPUTS
3,000 RECORD DATA STORAGE
50-RECORD CONFIGURABLE RECIPE DATABASE
Report wizard: ISO-14644-1, EU GMP Annex 1, FS-209ESTANDARD CHANNEL SIZES: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0 µm
INCLUDES
OPERATING MANUAL ON CD; ISOKINETIC SAMPLE PROBE WITH TRIPOD AND TUBING; PURGE FILTER; POWER CABLE AND SPARE FUSE; LMS XCHANGE AND EXPRESS SOFTWARE; PRINTER; PRINTER PAPERQUANTITY: 1
Learn More -
J-2786 VERTICAL MODULE FOR TEMPERATURE MEASUREMENT & FACE RECOGNITIONUSES ROCKCHIP RK3288 / RK 3399 / QUALCOMM MSM8953 HIGH-PERFORMANCE HARDWARE PLATFORM, EQUIPPED WITH INDUSTRIAL GRADE BINOCULAR CAMERA, LIVE FACIAL RECOGNITION SOFTWARE AND INFRARED THERMAL IMAGING MODULE TO SUPPORT FACE-WITH-MASK INDEITIFICATION.
SUPPORTS EXPANSION OF VARIOUS PERIPHERALS SUCH AS ID CARD READERS, FINGERPRINT READERS, ETC WHICH CAN BE APPLIED TO GATE PASSAGES AND ATTENDANCE SYSTEM TO ACHIEVE SAFE AND EFFICIENT ACCESS CONTROL FOR PERSONNEL
CAN BE USED WITH ACCESS GATES & ATTENDANCE FOR COMMUNITIES, OFFICES, SCHOOLS, HOTELS, PUBLIC VENUES, TRANSPORTATION HUBS AND PUBLIC SERVICE PLACES
FEATURES:
8 INCH IPS FULL-VIEW LCD DISPLAY
INDUSTRIAL APPEARANCE, WATERPROOF AND SUNPROOF DESIGN
STABLE AND RELIABLE
SUPPORTS A DATABASE OF 30,000 FACES
THE 1:1 COMPARISON RECOGNITION RATE IS MORE THAN 99.7%
THE 1:N COMPARISON RECOGNITION RATE IS MORE THAN 96.7% @ 0.1% MISRECOGNITION RATE
LIVE DETECTION ACCURACY RATE: 98.3% @ 1% MISRECOGNITION RATE
FACE RECOGNITION PASS SPEED IS LESS THAN 1 SECOND
SUPPORTS ACCURATE FACE RECOGNITION AND COMPARISON WHILE WEARING A MASK
USES INDUSTRIAL GRADE BINOCULAR WIDE DYNAMIC CAMERA, NIGHT INFRARED AND LED DUAL PHOTO FLOOD LAMP
ROCKCHIP RK3288 QUAD-CORE PROCESSOR, ROCKCHIP RK3399 SIX-CORE PROCESSOR, AND QUALCOMM MSM8953 OCTA-CORE PROCESSOR
SUPPORTS HUMAN BODY TEMPERATURE DETECTION AND DISPLAY (BEST TEMPERATURE DETECTION DISTANCE IS 0.5 METERS, MAXIMUM IS 1 METER), MEASUREMENT ERROR +/- 0.5 °C
TEMPERATURE CAN BE READ IN ONLY A FEW SECONDS AND THE DEVICE AUTOMATICALLY SOUNDS AN ALARM FOR ABNORMALITIES
ATTENDANCE TEMPERATURE MEASUREMENT DATA EXPORTED IN REAL TIME
VARIOUS PERIPHERALS AVAILABLE FOR ID CARD READING, FINGERPRINT READING, IC CARD READING, 2-DIMENSIONAL CODE READING, ETC.
WITH COMPLETE DOCUMENTATION AND SUPPORT FOR SECONDARY DEVELOPMENT
SUPPORTS SYSTEM LEVEL, APP OFFLINE LEVEL, APP AND BACKGROUND NETWORK LEVEL MULTIPLE API DOCKINGCAMERA
RESOLUTION 2 MILLION PIXELS
TYPE BINOCULAR WIDE DYNAMIC CAMERA
APERTURE F2.4
FOCUSING DISTANCE 50-150CM
WHITE BALANCE AUTO
PHOTO FLOOD LIGHT LED AND IR DUAL PHOTO FLOOD LIGHTSCREEN
SIZE 8.0 INCH IPS LCD SCREEN
RESOLUTION 800×1280
TOUCH NOT SUPPORTED (OPTIONAL SUPPORT)PROCESSOR
CPU RK3288 QUAD-CORE (OPTIONAL RK3399 SIX-CORE, MSM8953
EIGHT-CORE)
STORAGE EMMC 8GINTERFACE
NETWORK MODULE ETHERNET AND WIRELESS (WIFI)
AUDIO 2.5W / 4R SPEAKERS
USB 1 USB OTG, 1 USB HOST STANDARD A PORT
SERIAL COMMUNICATION 1 RS232 SERIAL PORT
RELAY OUTPUT 1 DOOR OPEN SIGNAL OUTPUT
WIEGAND ONE WIEGAND 26/34 OUTPUT, ONE WIEGAND 26/34 INPUT
UPGRADE BUTTON SUPPORT UBOOT UPGRADE BUTTON
WIRED NETWORK 1 RJ45 ETHERNET SOCKETFUNCTION
CREDIT CARD READER NONE (OPTIONAL IC CARD READER, ID CARD, ID CARD)
FACE DETECTION SUPPORTS DETECTION AND TRACKING OF MULTIPLE PEOPLE AT THE SAME
TIME
FACE LIBRARY UP TO 30,000
1: N FACE RECOGNITION SUPPORT
1: 1 FACE COMPARISON SUPPORT
STRANGER DETECTION SUPPORT
IDENTIFY DISTANCE
CONFIGURATION
SUPPORT
UI INTERFACE CONFIGURATION SUPPORT
UPGRADE REMOTELY SUPPORT
INTERFACE INTERFACES INCLUDE DEVICE MANAGEMENT, PERSONNEL / PHOTO
MANAGEMENT, RECORD QUERY, ETC.
DEPLOYMENT METHOD SUPPORT PUBLIC CLOUD DEPLOYMENT, PRIVATIZED DEPLOYMENT, LAN
USE, STAND-ALONE USEINFRARED THERMAL IMAGING MODULE
TEMPERATURE DETECTION SUPPORT
TEMPERATURE DETECTION 1 METER (OPTIMAL DISTANCE 0.5 METER)
DISTANCE
TEMPERATURE
MEASUREMENT ACCURACY
≤ ±0.5℃
TEMPERATURE
MEASUREMENT RANGE
10℃~42℃
THERMAL FIELD OF VIEW 32 X 32℃
VISITORS' TEMPERATURE IS
NORMAL AND RELEASED
DIRECTLY
SUPPORT
ABNORMAL TEMPERATURE
ALARM
SUPPORT (TEMPERATURE ALARM VALUE CAN BE SET)GENERAL PARAMETERS
POWER DC12V(±10%)
OPERATING TEMPERATURE 0℃~60℃
STORAGE TEMPERATURE -20℃~60℃
POWER CONSUMPTION 13.5W(MAX)
INSTALLATION METHOD GATE BRACKET INSTALLATION
SIZE : STANDARD:274.24*128*21.48(MM); IC CARD / ID CARD:296.18*132.88*25(MM)PACKING LIST
Learn More
MACHINE * 1, POWER ADAPTER * 1, MANUAL * 1, CERTIFICATE OF CONFORMITY * 1 -
L-7129 NONWOVEN SMS PRODUCTION LINE, 1600mm, SPUNBONDED, MELT BLOWNPP CHIPS FOR MELTBLOWN: 1200 TO 2000
FABRIC WIDTH: 1600mm
2 SPINNING BEAMS FOR SPUNBOND & 1 FOR MELTBLOWN
BASIC WEIGHT: SMS 9 TO 80 GRAMS PER SQUARE METER
SS: 15 TO 100 GRAMS PER SQUARE METERPRODUCT:
SMS LAMINATED NONWOVEN FABRIC
SS SPUNBOND NONWOVEN FABRIC SS
M MELTBLOWN NONWOVEN FABRIC MTO MAKE HYGENIC FABRICS SUCH AS BABY DIAPERS, SANITARY NAPKINS, ADULT DIAPERS, MEDICAL OPERATION SUITS, OPERATION CAPS, OPERATIONS SHOES, MASKS, ETC.
CONSISTING OF:
3 X FEEDING SYSTEMS
AUTOMATIC VACUUM SUCTION FOR BOTH MAIN MATERIAL AND ADDITIVES
CAPACITY (SB + MB) 2 X 520 KGS/H, (SB) 2 X 200 KGS/HR
WITH THREE HOPPERS, THREE SUPPLIYING DEVICESSPUNBOND SYSTEM
2 X EXTRUDERS
DIAMETER: 150mm
CAPACITY: 450 KGS/HR
L/D 30:1
DRIVE POWER: 110 KW
HEATING POWER: 90 KW2 X RECYCLING SYSTEMS
DIAMETER: 105mm
CAPACITY: 100 KGS PER HOUR
L/D: 15:12 X MELT FILTERS
WORKING TEMPERATURE: UP TO 280 CELSIUS
FILTRATION CAPACITY: 520 KGS PER HOUR2 X METERING PUMPS
TYPE: GEAR PUMP
FLOW VOLUME: 250 ML/R
DESIGNING TEMPERATURE: 280 CELSIUS2 X MELT PIPELINES
WITH STATIC MIXER2 X MONOMER EXHAUSTER
INCLUDING BLOWER, CHILLER, PIPELINE, VALVE, INSULATION, ETC2 X SPINNING BEAMS
SINGLE COAT-HANGER MELT DISTRIBUTION
DESIGNING PRESSURE: 9MPA
WORKING TEMPERATURE: MAX 280 CELSIUS4 X SPINNERETS
HOLE DIAMETER: 0.45mm
L/D: 5:1
15,500 HOLESMELTBLOWN SYSTEM
1 X EXTRUDER
DIAMETER 120mm
CAPACITY: 280 KGS/HR
L/D: 30:1
DRIVE POWER: 75 KW
HEATING POWER: 80 KW1 X MELT FILTER
FILTRATION PRECISION: 20 TO 60 MICROMETERS
FILTRATION: 280 KGS PER HOUR1 X METERING PUMP
GEAR PUMP
MAX. FLOW VOLUME: 100ML/R
DESIGNED TEMPERATURE: 300 CELSIUS1 X MELT PIPELINE
WITH STATIC MIXER1 X SPINNING BEAM
INCLUDING STRETCHING CHANNEL, NOZZLE, ETC. WITH INSULATION MATERIAL
DESIGNED PRESSURE: 6 MPA2 X SPINNING DIE PACKS
COMPACT DIE PACKS
HOLE DIAMETER: 0.35mm
L/D: 12:1
# OF HOLES: 42HPI1 X SCREW BLOWER
INCLUDING MUFFLE, PRESSURE REDUCER VALVE, PIPELINE, ETC.
POWER: 200 KW1 X HOT AIR SYSTEM
FLOW VOLUME: 6000 CUBIC METERS PER HOUR
WORKING TEMP: MAX 350 CELSIUS
INCLUDING HEATER, STAINLESS STEEL PIPELINE, ETC.
POWER: 290 KW1 X OFF-LINE CONVEYOR
RANGE OF SPEED: 5 TO 100 METERS PER MINUTE1 X CONVEYOR
MECHANICAL SPEED: MAX 400 METERS PER MINUTE
BELT WIDTH AND PENETRATION
3800±10mm, 10000 CUBIC METERS PER H.M21 X CALENDAR
DOUBLE ROLLS HEATED BY OIL
PROCESS SPEED: 350 METERS PER MINUTE
EMBOSSING WIDTH: UP TO 2000mm
MAX LINEAR PRESSURE: 110 DAN/C
MAX. TEMP OF EMBOSSING ROLLER, 180 CELSIUS1 X WINDER
ONLINE CHANGING ROLL, ONLINE EDGE CUTTING, TENSION CONTROL
MAX. LINEAR SPEED: 350 METERS PER MINUTE
WIDTH: 1600mm
WIND DIAMETER: MAX 1500mm1 X SLITTER
MAX. LINE SPEED: 600 METERS PER MINUTE
MAX. WIND DIAMETER: 1200mm
MIN. SLITTING WIDE: 120mm
22 CIRCULAR BLADES1 X STEEL PLATFORM
1 X ELECTRICAL CONTROL SYSTEM
2 X OIL OVEN
1 X AIR CONDITIONING SYSTEM
1 X WATER COOLING SYSTEM
1 X CLEANING EQUIPMENTS FOR DIE PACK
1 X AUXILIARY PLATFORM
1 X AUXILIARY EQUIPMENTS
1 X LABORATORY TESTING DEVICE
Learn More -
V-1816 AUTOMATIC RESPIRATOR REPLACEMENT FILTER MAKING MACHINEAUTOMATIC RESPIRATOR REPLACEMENT FILTER MAKING MACHINE IS ALSO CALLED A PARTICULATE RESPIRATOR FILTER MAKING MACHINE OR HALF FACE RESPIRATOR FILTER MAKING MACHINE, IT’S MADE UNDER MATURE TECHNOLOGY THAT SUPPORTS AUTOMATICALLY MATERIAL FEEDING, WELDING, PUNCHING AND CUTTING, REPLACEMENT FILTER FORMING, THIS MACHINE IS EASY TO OPERATE, BY CHANGING THE ROLLER, IT CAN PRODUCE DIFFERENT SHAPES OF FILTER. THIS MACHINE INCORPORATES ADVANCED ULTRASONIC WELDING AND EQUIPPED WITH CONSTANT TEMPERATURE CONTROLLER WHICH ENSURES THE FILTER FIRMLY AND CLEARLY WELDED.
FEATURES:
1. ADVANCED ULTRASONIC TECHNOLOGY WITH FIRM WELDING EFFECT, IT’S EQUIPPED WITH PULL AND PUSH TYPE MATERIAL FEEDING WHICH MAKES IT EASIER OPERATING.
2. THE MOLD (PATTERN ROLLER) CAN BE CUSTOMIZED TO PRODUCE DIFFERENT FILTERS.
3. THE WELDING LINE IS CLEAR AND FIRM.
ITEM NAME
TECHNICAL PARAMETERS
QTY
REMARK
SPECIFICATION
1800mm X 1200mm X 1800mm
1
HONGDA
WEIGHT
500KG
EFFICIENCY
20 TO 30PCS/MIN
VOLTAGE
220V/380V
AIR PRESSURE
3-6KG/CM²
FREQUENCY
15/20KHZ
POWER
4200W
MOLD SERVO MOTOR
SGM7G-09AFC61 4.4KW
1
YASKAWA
ULTRASONIC POWER SERVO MOTOR
SGM7G-13AFC61 1.3KW
2
YASKAWA
MATERIAL PULLING SERVO MOTOR
SGM7G-09AFC61 0.85KW
2
YASKAWA
MATERIAL FEEDING/CORRECTING/INDENTATION MOTOR
130BYG-350A
4
SONGYANG
POUCHING MOTOR
110BYG-350B
4
SONGYANG
110 STEPPER MOTOR
110BYG-350A
10
SONGYANG
UP AND LOWER MOTOR
90BYG-350A
2
SONGYANG
STEPPER MOTOR 56
SY57STH56-2004A
8
SONGYANG
DIRECT CURRENT MOTOR
0.4KW
2
DIRECT CURRENT MOTOR
0.6KW
1
ASYNCHRONOUS THREE-PHASE MOTOR
90S-6
1
0.75KW
FREQUENCY CONVERTER
AVF200-0152
1
1.5KW
MAIN PNEUMATIC COMPONENTS: AIRTAC (TAIWAN); MAIN ELECTRICAL COMPONENTS: PANASONIC (JAPAN), SICK (GERMANY), DONLIM (CHINA&JAPAN), ETC.
EMAIL US FOR PRICE & PICTURES
INCLUDE OUR REFERENCE NUMBER
Learn More -
D-2380 AUTOMATED FILTER TESTERTHE AUTOMATED FILTER TESTER MODEL 9981 CONTINUES TO BE THE BEST SOLUTION FOR TESTING PARTICULATE RESPIRATOR FILTERS, DISPOSABLE FILTERING FACE PIECES, AND A WIDE ASSORTMENT OF FILTER MEDIA. OUR FILTER TESTERS HAVE BEEN USED IN QUALITY CONTROL AND MANUFACTURING BY LEADING FILTER AND FILTER MEDIA MANUFACTURERS AND REFERENCE TEST INSTITUTES AROUND THE WORLD FOR MORE THAN 20 YEARS DUE TO THEIR PROVEN DURABILITY AND RELIABILITY, WHICH IS VALUED IN DEMANDING MANUFACTURING ENVIRONMENTS AND QA/QC LABORATORIES.
THIS MODEL OFFERS HIGHER SENSITIVITY AND RESOLUTION THAN PREVIOUS MODELS - UP TO 99.9999 PERCENT EFFICIENCY HAS BEEN PRODUCED WITH EMERY OIL AT CONCENTRATIONS OF 200 MG/M³. THE NEW SERVICEABLE PHOTOMETERS ARE LOWERING THE COST OF OWNERSHIP AND ENABLE PROACTIVE SCHEDULING OF MAINTENANCE FOR MINIMAL IMPACT TO PRODUCTION SCHEDULES.
THE MODEL 9981 FEATURES A HIGH DEGREE OF AUTOMATION AND SELF-DIAGNOSTICS THAT GREATLY SIMPLIFIES OPERATION, INCREASES THROUGHPUT, AND IMPROVES OVERALL MEASUREMENT PERFORMANCE. WHEN LOOKING FOR A STAND-ALONE TESTER TO DETERMINE PENETRATION OR FILTER EFFICIENCY AND PRESSURE DROP OF YOUR MEDIA, FILTER CARTRIDGES, FILTERS, AND RESPIRATORY MASKS THE MODEL 9981 IS UP TO THE CHALLENGE.
THE BUILT-IN CAPABILITY TO TEST WITH SALT AND OIL MEANS THAT JUST ONE UNIT IS NEEDED TO TEST YOUR PRODUCT TO:
• US 42 CFR 84, GB2626, JMOL
• ISO 16900-3, EN 143
• ISO 23328-1 (AND MORE)
APPLICATIONS
• USA COMMERCIAL RESPIRATOR REGULATION 42 CFR PART 84
• CHINESE RESPIRATOR STANDARD GB2626
• JAPANESE RESPIRATOR STANDARD JMOL
• EUROPEAN EN 143, ISO 16900-3 AND RELATED RESPIRATOR STANDARDS
• ISO 23328-1 (TESTING FILTERS FOR ANAESTHETIC USE)
• FILTER MEDIA TESTING
• CONSULT OUR REPRESENTATIVE FOR MORE DETAILS
INCLUDED ITEMS
• REFERENCE MEDIA SHEETS
• FLAT-MEDIA AND GRAVIMETRIC FILTER HOLDER
• REFERENCE PRESSURE DROP PLATE
• OIL AND SALT AEROSOL GENERATORS
• SELECTED SPARE PARTS
• CONTACT US FOR CUSTOM FILTER HOLDERSEMAIL US FOR PRICE & PICTURES
Learn More
INCLUDE OUR REFERENCE NUMBER -
J-2792 MEDICAL FACE MASK SYNTHETIC BLOOD PENETRATION TESTERUSED FOR MEASURING THE RESISTANCE OF MEDICAL FACE MASKS TO PENETRATION BY A SPLASH OF SYNTHETIC BLOOD
BLOOD SPRAYING DISTANCE: 300 TO 310mm (APPROXIMATE, ADJUSTABLE)
NEEDLE INNER DIAMETER: 0.84mm
SPRAY SPEED: 4500mm PER SECOND, 5500mm PER SECOND, 6350mm PER SECOND
SIMULATED SYNTHETIC BLOOD PRESSURE: 10.6kPa, 16.0 kPa, 21.3 kPa, (i.e. 80mmHg, 120mmHg, 160mmHg)
SUPPORTS THE SPECIMEN MEDICAL FACE MASK ON THE TESTER’S CLAMPING DEVICE AND SPRAYS A FIXED VOLUME (~2ml) OF SYNTHETIC BLOOD SPLASHED HORIZONTALLY TO HIT THE MASK
TESTER CAN PROVIDE DIFFERENT BLOOD PRESSURES WITH PRECISION CONTROL VALVE TO GENERATE 2ml SYNTHETIC BLOOD WITH SURFACE TENSION OF 0.042 ± 0.002 N/m, WHICH MEETS THE REQUIREMENTS DEFINED IN STANDARDS BELOW:
ISO 22609
ASTM F1862
YY 0469-2011
GB/T 19083-2010LEAD TIME: 5 TO 7 WEEKS FROM RECEIPT OF ORDER
QUANTITY: 1
Learn More -
J-2785 VERTICAL MODULE FOR TEMPERATURE MEASUREMENT & FACE RECOGNITIONUSES ROCKCHIP RK3288 / RK 3399 / QUALCOMM MSM8953 HIGH-PERFORMANCE HARDWARE PLATFORM, EQUIPPED WITH INDUSTRIAL GRADE BINOCULAR CAMERA, LIVE FACIAL RECOGNITION SOFTWARE AND INFRARED THERMAL IMAGING MODULE TO SUPPORT FACE-WITH-MASK INDEITIFICATION.
SUPPORTS EXPANSION OF VARIOUS PERIPHERALS SUCH AS ID CARD READERS, FINGERPRINT READERS, ETC WHICH CAN BE APPLIED TO GATE PASSAGES AND ATTENDANCE SYSTEM TO ACHIEVE SAFE AND EFFICIENT ACCESS CONTROL FOR PERSONNEL
CAN BE USED WITH ACCESS GATES & ATTENDANCE FOR COMMUNITIES, OFFICES, SCHOOLS, HOTELS, PUBLIC VENUES, TRANSPORTATION HUBS AND PUBLIC SERVICE PLACES
FEATURES:
8 INCH IPS FULL-VIEW LCD DISPLAY
INDUSTRIAL APPEARANCE, WATERPROOF AND SUNPROOF DESIGN
STABLE AND RELIABLE
SUPPORTS A DATABASE OF 30,000 FACES
THE 1:1 COMPARISON RECOGNITION RATE IS MORE THAN 99.7%
THE 1:N COMPARISON RECOGNITION RATE IS MORE THAN 96.7% @ 0.1% MISRECOGNITION RATE
LIVE DETECTION ACCURACY RATE: 98.3% @ 1% MISRECOGNITION RATE
FACE RECOGNITION PASS SPEED IS LESS THAN 1 SECOND
SUPPORTS ACCURATE FACE RECOGNITION AND COMPARISON WHILE WEARING A MASK
USES INDUSTRIAL GRADE BINOCULAR WIDE DYNAMIC CAMERA, NIGHT INFRARED AND LED DUAL PHOTO FLOOD LAMP
ROCKCHIP RK3288 QUAD-CORE PROCESSOR, ROCKCHIP RK3399 SIX-CORE PROCESSOR, AND QUALCOMM MSM8953 OCTA-CORE PROCESSOR
SUPPORTS HUMAN BODY TEMPERATURE DETECTION AND DISPLAY (BEST TEMPERATURE DETECTION DISTANCE IS 0.5 METERS, MAXIMUM IS 1 METER), MEASUREMENT ERROR +/- 0.5 °C
TEMPERATURE CAN BE READ IN ONLY A FEW SECONDS AND THE DEVICE AUTOMATICALLY SOUNDS AN ALARM FOR ABNORMALITIES
ATTENDANCE TEMPERATURE MEASUREMENT DATA EXPORTED IN REAL TIME
VARIOUS PERIPHERALS AVAILABLE FOR ID CARD READING, FINGERPRINT READING, IC CARD READING, 2-DIMENSIONAL CODE READING, ETC.
WITH COMPLETE DOCUMENTATION AND SUPPORT FOR SECONDARY DEVELOPMENT
SUPPORTS SYSTEM LEVEL, APP OFFLINE LEVEL, APP AND BACKGROUND NETWORK LEVEL MULTIPLE API DOCKINGCAMERA
RESOLUTION 2 MILLION PIXELS
TYPE BINOCULAR WIDE DYNAMIC CAMERA
APERTURE F2.4
FOCUSING DISTANCE 50-150CM
WHITE BALANCE AUTO
PHOTO FLOOD LIGHT LED AND IR DUAL PHOTO FLOOD LIGHTSCREEN
SIZE 8.0 INCH IPS LCD SCREEN
RESOLUTION 800×1280
TOUCH NOT SUPPORTED (OPTIONAL SUPPORT)PROCESSOR
CPU RK3288 QUAD-CORE (OPTIONAL RK3399 SIX-CORE, MSM8953
EIGHT-CORE)
STORAGE EMMC 8GINTERFACE
NETWORK MODULE ETHERNET AND WIRELESS (WIFI)
AUDIO 2.5W / 4R SPEAKERS
USB 1 USB OTG, 1 USB HOST STANDARD A PORT
SERIAL COMMUNICATION 1 RS232 SERIAL PORT
RELAY OUTPUT 1 DOOR OPEN SIGNAL OUTPUT
WIEGAND ONE WIEGAND 26/34 OUTPUT, ONE WIEGAND 26/34 INPUT
UPGRADE BUTTON SUPPORT UBOOT UPGRADE BUTTON
WIRED NETWORK 1 RJ45 ETHERNET SOCKETFUNCTION
CREDIT CARD READER NONE (OPTIONAL IC CARD READER, ID CARD, ID CARD)
FACE DETECTION SUPPORTS DETECTION AND TRACKING OF MULTIPLE PEOPLE AT THE SAME
TIME
FACE LIBRARY UP TO 30,000
1: N FACE RECOGNITION SUPPORT
1: 1 FACE COMPARISON SUPPORT
STRANGER DETECTION SUPPORT
IDENTIFY DISTANCE
CONFIGURATION
SUPPORT
UI INTERFACE CONFIGURATION SUPPORT
UPGRADE REMOTELY SUPPORT
INTERFACE INTERFACES INCLUDE DEVICE MANAGEMENT, PERSONNEL / PHOTO
MANAGEMENT, RECORD QUERY, ETC.
DEPLOYMENT METHOD SUPPORT PUBLIC CLOUD DEPLOYMENT, PRIVATIZED DEPLOYMENT, LAN
USE, STAND-ALONE USEINFRARED THERMAL IMAGING MODULE
TEMPERATURE DETECTION SUPPORT
TEMPERATURE DETECTION 1 METER (OPTIMAL DISTANCE 0.5 METER)
DISTANCE
TEMPERATURE
MEASUREMENT ACCURACY
≤ ±0.5℃
TEMPERATURE
MEASUREMENT RANGE
10℃~42℃
THERMAL FIELD OF VIEW 32 X 32℃
VISITORS' TEMPERATURE IS
NORMAL AND RELEASED
DIRECTLY
SUPPORT
ABNORMAL TEMPERATURE
ALARM
SUPPORT (TEMPERATURE ALARM VALUE CAN BE SET)GENERAL PARAMETERS
POWER DC12V(±10%)
OPERATING TEMPERATURE 0℃~60℃
STORAGE TEMPERATURE -20℃~60℃
POWER CONSUMPTION 13.5W(MAX)
INSTALLATION METHOD GATE BRACKET INSTALLATION
SIZE : STANDARD:274.24*128*21.48(MM); IC CARD / ID CARD:296.18*132.88*25(MM)PACKING LIST
MACHINE * 1, POWER ADAPTER * 1, MANUAL * 1, CERTIFICATE OF CONFORMITY * 1QUANTITY: 1
Learn More