Search results for: 'control+pro'
- Related search terms
- control+prog
- control+programs
- control+pro'[0]
- control+pro'[0]'
- control+pro'
-
TT-1047 MICRO COMPUTER TENSILE STRENGTH TESTING MACHINETT-1047 MICRO COMPUTER TENSILE STRENGTH TESTING MACHINE TENSILE COMPRESSION TESTING MACHINE KEY SPECIFICATIONS CAPACITY: 50N, 100N, 200N, 500N, 1KN, 2KN,2.5KN DISPLAY: LCD DISPLAY FORCE RESOLUTION: 1/50,000 FORCE ACCURACY: ≤+/-0.5% STROKE RANGE: 1100mm (EXCLUDE THE GRIPS) STROKE RESOLUTION: 0.001mm TEST SPEED: 0.001-500mm/MIN CAN BE SET, WITH UP & DOWN FAST ADJUSTMENT BUTTON OF GRIPS FORCE UNIT SWITCH: KGF, N, IBF, G, TON, MPA STOP MODE: OVERLOAD STOP, EMERGENCY STOP BUTTON. SPECIMEN DAMAGE AUTOMATIC STOP MACHINE DRIVE: AC INVERTER MOTOR DRIVE POWER SUPPLY: AC 220V 50-60Hz 5A DIMENSIONS: 470 X 380 X 1860mm WEIGHT: 60KG QUANTITY: 1 Learn More -
TT-1041UNIVERSAL TENSILE STRENGTH TESTER, 50KNTT-1041UNIVERSAL TENSILE STRENGTH TESTER, 50KN 50KN TENSILE STRENGTH TEST KEY SPECIFICATIONS: CAPACITY KGF 5000, 10000, 15000 KN 50, 100, 150 UNIT: LOAD N, KN, G, KG, TON, LB DISPLACEMENT: mm, CM, INCH LOAD RESOLUTION: 1/20,000 LOAD ACCURACY: ±1% (±0.5% OPTIONAL) LOAD AMPLIFICATION: X 1, X 2, X 5, X 10 AUTO RANGE TESTING WIDTH (mm): 800 CROSSHEAD TRAVEL (mm): 1480 TESTING STROKE: CROSSHEAD TRAVEL MINUS UPPER/LOWER GRIPS AND GRIPPING LENGTH TEST SPEED RANGE (mm/MIN): 0.5~500 OR 0.2~200 MAXIMUM FORCE AT FULL SPEED (KGF): 2000 MAXIMUM SPEED AT FULL LOAD (mm/MIN): 100 SPEED ACCURACY: ±0.5% SERVO CONTROL DISPLACEMENT RESOLUTION (mm): 0.001 DRIVING METHOD: AC SERVO MOTOR POWER: SPECIFICATIONS 3Ø, 220VAC, 50/60Hz (380/415V OPTIONAL) CAPACITY: 5000KGF, 10000KGF, 15000KGF 50KN, 100KN, 150KN CONSUMPTION: 3KVA DIMENSIONS: FRAME (mm) 1540 X 600 X 2130 CONTROL BOX (mm): COMPUTER TYPE 1200 X 600 X 740 MICRO-COMPUTER TYPE 660 X 600 X 740 WEIGHT (KG): FRAME 800, CONTROL BOX 100 STANDARD ACCESSORIES: TENSILE GRIPS X 1 SET, NECESSARY TOOLS X 1 SET, OPERATIONAL MANUAL X 1 COPY, CERTIFICATE OF CALIBRATION X 1 COPY QUANTITY: 1 Learn More -
TT-1046 HORIZONTAL TENSILE TESTING MACHINETT-1046 HORIZONTAL TENSILE TESTING MACHINE KEY SPECIFICATION: CAPACITY: 500N DISPLAY: COMPUTER DISPLAY FORCE RESOLUTION: 1/100,000 FORCE ACCURACY: ≤+/-0.5% STROKE RANGE: 600mm STROKE RESOLUTION: 0.001mm TEST SPEED: 0.001-500mm/MIN CAN SET ON DISPLAY, WITH UP & DOWN FAST ADJUSTMENT BUTTON OF GRIPS FORCE UNIT SWITCH: KGF, N, IBF, G, TON, MPA STOP MODE: OVERLOAD STOP, EMERGENCY STOP BUTTON. SPECIMEN DAMAGE AUTOMATIC STOP MACHINE DRIVE: SERVO MOTOR DRIVE, SYNCHRONOUS WHEEL AND PRECISION BALL SCREW DRIVE POWER SUPPLY: AC 220V 50/60Hz 10A DIMENSIONS: 800 X 400 X 500mm WEIGHT: 50KG QUANTITY: 1 Learn More -
T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTERREFERENCE NUMBER: T-6545
MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
PRODUCT INTRODUCTION:
MASK BACTERIA FILTRATION EFFICIENCY KEY PERFORMANCE INDICATORS (BFE) DETECTOR TESTER NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASKS TECHNOLOGY YY0469-2011 APPENDIX B IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST B. 1.1.1 TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL ASTMF2100, ASTMF2101, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING,IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENTIFIC RESEARCH INSTITUTES, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY.
EXECUTION STANDARD:
Q/0212 ZRB003-2015 MEDICAL SURGICAL MASK
BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR RELATED INTELLECTUAL PROPERTY:
NO.: ZL200820224142.6 ELECTRIC FLOW CONTROL VALVE
NO.: ZL200820224143.0 GAS CAPACITY
NO.: ZL200920308391.8 AIR FILTRATIONMATERIAL FILTRATION EFFICIENCY DETECTOR
PRODUCT FEATURES:
NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS;
BUILT -IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET, A, B TWO -WAY, SIX ANDERSEN; THE PERISTALTIC PUMP FLOW CAN BE SET;
THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD.
EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL; 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN;
USB INTERFACE, SUPPORT U DISK DATA STORAGE;
CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS; BUILT-IN LEAKAGE PROTECTION SWITCH TO PROTECT THE SAFETY OF OPERATORS;
THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT.
THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE.
DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT; SUPPORTING AND MOVING DUAL PURPOSE CASTERS.
QUANTITY: 1
Learn More -
T-9600 XENON ARC LIGHT FASTNESS TESTERT-9600 XENON ARC LIGHT FASTNESS TESTER KEY SPECIFICATION: CHAMBER TEMPERATURE: 25-55℃; RESOLUTION: 0.1℃ CHAMBER HUMIDITY: LIGHT CYCLE: 10-70%RH; RESOLUTION: 0.1RH% DARK CYCLE: 30-95%RH; RESOLUTION: 0.1RH% BST: 40-85℃; ACCURACY: ±1℃; RESOLUTION: 0.1℃ BPT (OPTION): 40-80℃, ACCURACY: ±2℃; RESOLUTION: 0.1℃ TIME CONTROL RANGE: ≤10000H IRRADIANCE CONTROL RANGE: 0.80-1.20W/M²@420NM (OPTION: 340NM, 420NM, 300-400NM OR 280-800NM) ACCURACY: ±0.02W/M²@420NM. DIGITAL SETTING, CLOSED-LOOP AUTOMATIC COMPENSATION XENON ARC LAMP RATED POWER: 2500W SAMPLE HOLDER ROTATION SPEED: 2-7 RPM SAMPLE HOLDERS CAPACITY: ISO: 145 × 45mm 12PCS OR AATCC: 145 × 70mm 6PCS TIMING OF EACH SAMPLE HOLDER, RESPECTIVELY: ≤10000H LIGHT PERIOD: ≤1000H SPRAY PERIOD: ≤1000H POWER: AC220V ±10% 50Hz 6.5KW RATED POWER: 3.3KW DIMENSION: 920 × 650 × 1680mm WEIGHT: 180KG Learn More -
HUMAN BODY ELEMENTS ANALYSIS MACHINEREFERENCE NUMBER: Y-2080 HUMAN BODY ELEMENTS ANALYSIS MACHINE HUMAN BODY ELEMENTS ANALYSIS EQUIPMENT, APPLIES THE ACCURATE MEASUREMENTS OF AVR MICROCOMPUTER CONTROLLER BASE ON NEW STATIC METHOD DXA, ANALYSIS HUMAN ELEMENTS, FAT WEIGHT BMI (BODY MASS INDEX), NON-FAT AND OTHER HEALTH INDICATORS THROUGH MULTI-FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS METHOD (MFBIA). ALLOW YOU TO LOOSE WEIGHT EFFECTIVELY ON A SCIENTIFIC BASIS. WHICH IS CONSIDERED AS AN EPOCH-MAKING RESULT OF THE HEALTH INDUSTRY. IF YOU ARE A HEALTH CONSULTANT ,IT CAN PROVIDE AN INDEPENDENT ANALYSIS OF HEALTH DATA FOR EACH TEST. APPLICABLE FOR FITNESS CENTERS , MEDICAL CENTERS, SENIOR CLUBS. SUPPORTING PROJECTS OF WEIGHT LOSS . DATA FUNCTION: ANALYSES THE SLIMMING EFFECT TO PROVIDE A THE SLIMMING TREATMENT, ON A SCIENTIFIC BASIS. THE REASONABLE WEIGHT CONTROL HELPS MAINTAIN THE BEST PHYSICAL STRENGTH AND DISTINGUISH BETWEEN MUSCLE TYPE, OVERWEIGHT AND/OR OBESITY. FINDS THE BEST CONTROL WEIGHT METHOD. SUGGESTS DIRECT ENERGY INTAKE AND DIETARY INTAKE OF NUTRIENTS IN CORRECT PROPORTIONS. GUIDING NUTRITION GUIDELINES AND RECOVERY MEASURES TO PROMOTE SYNTHESIS OF MUSCLES MASS. EVALUATION OF THE REHABILITATION TREATMENT EFFECT, GUIDING SCIENTIFIC BODY SLIMMING WITH SCIENTIFIC TRAINING, REHABILITATION, AND NUTRITION. DETECTS THE STATUS OF THE PHYSICAL AND HEALTH OF TEENAGERS, DEVELOPING FOR THEM A FEASIBLE EXERCISE PROGRAM. CLARIFY THE NUTRITION, AND OTHER FACTORS ON BODY COMPOSITION EFFECTS. SUGGEST INCIDENCE OF IMPORTANT PREVENTIVE MEASURES TO ATTEMPT TO REDUCE DIABETES. ADVANTAGES: WITH CE CERTIFICATE IT IS MULTI-FREQUENCY, INCLUDES 20KHz, 50KHz, AND 100KHz. IT CAN MEASURE YOUR WHOLE BODY. IT INCLUDES AN INBUILT MICRO THERMAL PRINTER AND HP COLOR PRINTER AT NO CHARGE THE ELECTRODE METHOD IS 8 POINT CONTACT ELECTRODE WHICH MAKES THE MEASUREMENT MORE ACCURATE. IT ANALYSIS A TOTAL OF 25 VALUE OF BODY COMPOSITIONS AND PROVIDES A HIGHLY ACCURATE WHOLE BODY ANALYSIS IN UNDER 10 SECONDS. THE COMPUTER HAS WIFI AND WIRELESS CONNECTION CAPABILITY SPECIFICATION: INPUT: 220V, 60Hz POWER: 53VA RATED CURRENT: <180μA SIZE: 390mm X 530mm x 1000mm QUANTITY: 1 Learn More -
T-6546 PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKREFERENCE NUMBER: T-6546PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKINTRODUCTIONMEDICAL SURGICAL MASK PARTICLE FILTRATION EFFICIENCY PFE TESTER IS SUITABLE FOR MEDICAL INSTRUMENT INSPECTION CENTER, SAFETY PROTECTION INSPECTION CENTER, LABOR PROTECTION INSPECTION CENTER, DRUG INSPECTION CENTER, DISEASE PREVENTION AND CONTROL CENTER, TEXTILE INSPECTION CENTER, HOSPITAL, MASK AND RESPIRATOR MANUFACTURERS, ETC.FEATURESTHE PFE TESTER FOR PARTICLE FILTRATION EFFICIENCY OF SURGICAL MASKS IS EQUIPPED WITH A SPECIAL SALT AEROSOL GENERATOR, WHICH CAN PRODUCE AEROSOLS WITH SPECIFIC PARTICLE SIZE AND CONCENTRATION.EQUIPPED WITH A SERIES OF SPECIAL FIXTURE, SUITABLE FOR THE DETECTION OF ALL KINDS OF MASKS.BUILT-IN HIGH LIFE PHOTOMETER MODULE, SAMPLING TIME ACCUMULATION, PROMPT LIGHT CLEANING.AUTOMATIC CONTROL OF AEROSOL GENERATION, AUTOMATIC CALCULATION OF CAPTURE EFFICIENCY AND MASK AIRFLOW RESISTANCE, REDUCE HUMAN INTERVENTION.BUILT-IN HIGH PRECISION ELECTRONIC FLOWMETER AND HIGH PERFORMANCE SAMPLING PUMP TO ENSURE FLOW STABILITY.PARAMETERTEST FLOW: PARAMETER RANGE: (5 ~ 100) L/MIN; RESOLUTION: (5 ~ 100) L/MIN;MAXIMUM ALLOWABLE ERROR: ±1%PRESSURE DETECTION RANGE: PARAMETER RANGE: (0 ~ 2500) PA; RESOLUTION: 0.1PA; MAXIMUM ALLOWABLE ERROR: ±1%CONCENTRATION DETECTION RANGE: PARAMETER RANGE: (0.001 ~ 100) 0 G/L;DETECTION ACCURACY: 1% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100%DETECTION REPEATABILITY: 5% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100% MEDIAN DIAMETER OF SALT AEROSOL PARTICLES (CMD): (0.075±0.02)MMEDIAN AEROSOL PARTICLE NUMBER DIAMETER (CMD) (OPTIONAL): (0.185±0.02) MOPERATING TEMPERATURE: 20±5CLearn MoreINSTRUMENT NOISE: <60DB(A)POWER SUPPLY: AC220V±10%, 50HZMAIN MACHINE SIZE: (LENGTH 700 X WIDTH 720 X HEIGHT 1450) mmQUANTITY: 1 -
T-9596 BUTTON PULL TEST MACHINET-9596 BUTTON PULL TEST MACHINE FEATURE: 1. SNAP BUTTON PULL TEST MACHINE IS A SIMPLE BUT EFFECTIVE DESIGN MAINLY CONSISTING OF A HIGH PRECISION GAUGE, A STURDY REQUIRED BY STANDARDS & REGULATIONS IS BE FIXED HORIZONTALLY (CONSTANT FORCE IS APPLIED TO SECURE THE SAMPLE) SO THAT SNAP OR OTHER ACCESSORIES ATTACHED IN FABRIC CAN BE CLAMPED INTO. 2. MOREOVER, A STANDARD WEIGHT IS ALSO OFFERED SO THAT IT CAN BE REGULARLY CHECKED IF IT MEETS THE SAFETY REQUIREMENTS. 3. THE CAPABILITY OF THE BUTTON PULL TEST MACHINE CAN BE ENHANCED WITH CLAMPS & ACCESSORIES FOR TESTING OF OTHER SNAPS, JEAN BUTTONS, FOUR HOLE BUTTONS & GARMENTS ACCESSORIES SUCH AS ZIPPERS, BOWS, APPLIQUÉ, TOGGLES, HOOKS/BARS, AND D-RINGS, AMONGST OTHERS. SPECIFICATION: DIMENSIONS: 260 X 310 X 820mm NET WEIGHT: 32KG ACCESSORIES: STANDARD ACCESSORIES 1PC - IMADA FORCE GAUGE FB-30K 1PC - UPPER UNIVERSAL GRIP 1PC - UPPER STUD GRIP 1PC - LOWER FABRIC CLAMP & LEVEL ARM LOCKING 1PC - LOWER GRASP BUTTON ACCESSORY KIT 1PC - CALIBRATION WEIGHT 15LB 1PC - THREE PRONGED GRIP 1PC - UPPER LONG NOSE VISE GRIP Learn More -
T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTERREFERENCE NUMBER: T-6550
MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
TECHNICAL SPECIFICATIONS AND CONFIGURATION:
1. THE INSTRUMENT ADOPTS AN AIR SOURCE THAT CAN PROVIDE (0.5 ~ 30±0.1) KPA PRESSURE TO CONTINUOUSLY PRESSURIZED THE SAMPLE, WHICH IS NOT RESTRICTED BY THE SPACE OF THE TEST SITE;
2. THE AIR PRESSURE RANGE CAN BE ADJUSTED FREELY, AND THE ADJUSTMENT RANGE (0.5 ~ 30) KPA;
3. COLOR TOUCH SCREEN DISPLAY AND OPERATION;
4. THE SAMPLE CLAMPING PAD IS PROCESSED WITH IMPORTED SPECIAL ALUMINUM PROFILES, WHICH IS LIGHT IN MATERIAL, CLEAN IN SURFACE AND NEVER RUSTS.
5. THE INSTRUMENT ADOPTS IMPORTED SPECIAL ALUMINUM WIRE DRAWING PANEL, EQUIPPED WITH METAL KEYS, SENSITIVE OPERATION, NOT EASY TO DAMAGE;
6. CLAMPING DEVICE FOR INSTRUMENT SAMPLES, EQUIPPED WITH LOCKING PROTECTION, TO PREVENT THE SYNTHETIC BLOOD FROM SPLASHING AROUND;
7. CLAMPING FORCE IS ACCURATE AND RELIABLE;
8. THE TEST TANK IS EQUIPPED WITH A SPECIAL PLACEMENT DEVICE, WHICH IS CONVENIENT FOR CUSTOMERS TO OPERATE;
9. THE TEST TANK IS PROCESSED WITH SPECIAL 316 STAINLESS STEEL, AND THE TOP IS EQUIPPED WITH A SPECIAL COVER FOR HIGH TRANSPARENT PROTECTION;
10. THE WASHER BELOW THE SAMPLE IS MADE OF HIGH-QUALITY PTFE MATERIAL AFTER SPECIAL PROCESSING;
11. SQUARE METAL BLOCK NET: OPEN SPACE ≥50°%; BENDING ≤5mm AT 30KPA;
12. INSTRUMENT TIME CONTROL ACCURACY ≤01 SECONDS;
13. THE SHELL OF THE INSTRUMENT IS MADE OF HIGH-QUALITY METAL BAKING PAINT, WHICH IS BEAUTIFUL AND GENEROUS.
14. EQUIPPED WITH PRINTER INTERFACE, CONNECTED TO THE PRINTER CAN DIRECTLY PRINT DATA REPORTS.
TECHNICAL PARAMETERS:
1. SAMPLE SIZE: 75mm X 75mm
2. TEST AREA: 28.26 SQUARE CENTIMETERS
3. AIR PRESSURE ADJUSTMENT RANGE (0.5 ~ 30) KPA
4. EXTERNAL SIZE: 500mm X 500mm X 500mm (L X W X H)
5. WEIGHT OF THE INSTRUMENT: 40 KG
6. POWER SUPPLY: AC220V, 50HZ,SCOPE OF SUPPLY: 1. ONE MAIN MACHINE; 2. TWO PTFE GASKETS; 3. TWO ORDINARY WASHERS; 4. ONE METAL BLOCKING NET; 5. A SET OF SPECIAL LOCKING TOOLS; 6. ONE HIGH-QUALITY SILENT AIR PUMP, [NOTE: SAFETY PRODUCTION LICENSE IS NOT INCLUDED]. 7. EQUIPPED WITH PRINTER INTERFACE; 8. ONE SAMPLE TEMPLATE; 9. ONE PRODUCT CERTIFICATE; 10. ONE COPY OF PRODUCT OPERATION MANUAL.
OPERATION INSTRUCTION:
INSERT THE AIR PUMP OUTPUT PIPE INTO THE OIL AND WATER SEPARATOR OF THE INSTRUMENT AS REQUIRED (PRESSURE 0.1-0.3MPA).
AFTER SWITCHING ON THE POWER, THE STARTUP INTERFACE (NAME OF THE DEVICE) IS DISPLAYED.
PRESS THE "ENTER" BUTTON TO ENTER THE TEST INTERFACE, AS SHOWN IN THE FOLLOWING FIGURE:
CLICK "SETTING” BUTTON, GET INTO PARAMETER SETTING SCREEN, AS BELOW THIS SCREEN CAN SET THE SYSTEM TIME, DATE AND TESTING TIME, AFTER SETTING, CLICK "SAVE” BUTTON TO KEEP THE SETTING DATA. (NOTE: IT REQUIRES 5 MINUTES IN THE STANDARD)
QUANTITY: 1
Learn More -
YY-2183 OZONE AGING TEST CHAMBER, TEMPERATURE RANGE RT +10°C ~ 60°CYY-2183 OZONE AGING TEST CHAMBER, TEMPERATURE RANGE RT +10°C ~ 60°C DETAILS: IT IS WIDELY USED TO MEASURE QUALITY CONTROL; RUBBER & PLASTICS; AUTOMOBILE PRODUCTION; WIRES AND CABLES; PACKING MATERIALS; INSTRUMENTS AND MEASURING DEVICES; MEDICAL EQUIPMENT; CIVILIAN NUCLEAR ENERGY; CIVIL AVIATION; COLLEGES AND UNIVERSITIES; RESEARCH LABORATORIES; INSPECTION ARBITRATION, AND TECHNICAL SUPERVISION DEPARTMENTS AND OTHER PRODUCTS. CORRESPONDING STANDARDS: JIS K 6259, ASTM1149, ASTM1171, ISO1431, DIN53509, GB/T13642, GB/T 7762-2003, GB 2951. QUANTITY: 1 Learn More