Search results for: 'm-5'
-
T-9599 PERSPIROMETER / PERSPIRATION FASTNESS TESTERT-9599 PERSPIROMETER / PERSPIRATION FASTNESS TESTER KEY SPECIFICATION: WEIGHTS: A: 3.63KG (8LB), B: 0.45 (1LB), C: 0.90KG (2LB, PALLET) AATCC LOAD: A+C=10LB ISO LOAD: A+B+C=11LB DIMENSIONS: 165 X 75 X 145mm (L X W X H) WEIGHT: 8 KG Learn More -
T-9598 TEXTILE COLOR FASTNESS TO WASHING TESTERT-9598 TEXTILE COLOR FASTNESS TO WASHING TESTER KEY SPECIFICATION: CUP COMPOSITE MODE: 2A+2B, 4A+4B, 6A+6B, 8A+8B, 8A+12B, 12A, 8B, CUSTOMIZED AATCC CUP VOLUME (A): 1200ML ISO CUP VOLUME (B): 550ML CONTROL MODE: LCD COUNTER DISPLAY ROTATION SPEED: 40±2 RPM TEMPERATURE CONTROL RANGE: RT TO 100℃ HEATING METHODS: ELECTRICAL HEATING STAINLESS STEEL BALLS:¢6mm STAINLESS STEEL DRY CLEANING DISCS:¢30mm, THICKNESS: 3mm, MASS: 20G POWER SUPPLY: 3∮AC 380V 50/60Hz PACKED DIMENSIONS: 890 x 690 x 1200mm PACKED WEIGHT: 130 KG Learn More -
T-9597 FABRIC BURSTING STRENGTH TESTERT-9597 FABRIC BURSTING STRENGTH TESTER KEY SPECIFICATION: RANGE: 2.00MPA TO 10.000MPA THE MIN. DIVISION VALUE: 0.001MPA TO 0.003MPA TEST AREA: 73mm2 (Φ30.5mm), 100mm2 (Φ35.7mm), 500mm2 (Φ79.8mm), 1000mm2 (Φ112.8mm) CAN BE OPTION THICKNESS OF RUBBER DIAPHRAGM: ≤2mm PRESSURE SPEED: 20ML/MIN - 600ML/MIN MAXIMUM EXPANSION HEIGHT: 75 ± 0.02mm TESTING UNITS: KPA, KGF/ CM2, ATM, MMHG, LB/IN2 FREE SHIFT TEST METHOD: CONSTANT RATE BURSTING CONSTANT EXPANSION CONSTANT PRESSURE CONSTANT TIME BURSTING OUTPUT: PRINTER, DISPLAY OUTPUT AND CAN BE CONNECTED TO THE COMPUTER POWER SUPPLY: AC 220V 50/60HZ 200W DIMENSIONS: 550 × 450 × 700mm NET WEIGHT: 125KG Learn More -
T-9595 DIGITAL HYDROSTATIC HEAD TESTERT-9595 DIGITAL HYDROSTATIC HEAD TESTER KEY SPECIFICATION TESTING RANGE: 500PA-200KPA WATER PRESSURE INCREASE RATE: 1KPA-30KPA ACCURACY: 0.2 % F.S SPECIMEN TEST AREA: 1000mm2, OR 78mm2 (OPTION) TESTING MODE 1) P. RISE 2) CONST P & TIMING 3) CONST P & TIME 4) WATER PENETRATION 5) FATIGUE TESTING UNIT: PA, MMHG, CMH2O POWER SUPPLY: AC 220V 50/60Hz DIMENSION: 600 X 450 X 640mm (L X W X H) WEIGHT: 60 KG Learn More -
T-9593 CROCKMETER RUBBING FASTNESS TESTERT-9593 CROCKMETER RUBBING FASTNESS TESTER CROCKMETER RUBBING FASTNESS TESTER SUPPLY CAPACITY 500 SETS COMES WITH A STANDARD WEIGHT (9 N) ARM THAT COMPLIES TO A VARIETY OF STANDARDS INCLUDING AATCC 8 AND 165 AND TRADITIONAL SAMPLE HOLDER. APPLICATION: CROCKMETER RUBBING FASTNESS TESTER TO DETERMINE THE COLOR FASTNESS OF TEXTILES TO DRY OR WET RUBBING. A PINNED ACRYLIC SAMPLE HOLDER ENSURES RAPID SAMPLE MOUNTING AND REPEATABILITY OF RESULTS. FEATURE: 1. METAL BOX, HIGH-TEMPERATURE BAKING COATING, EASY MAINTENANCE. 2. ELECTRIC MOTOR, FITTED WITH A PRE-DETERMINED ELECTRONIC COUNTER FOR STROKES UP TO 9999, EXPERIMENT COMPLETE SUCCESSFULLY, AUTOMATIC STOP. Learn More -
HUMAN BODY ELEMENTS ANALYSIS MACHINEREFERENCE NUMBER: Y-2080 HUMAN BODY ELEMENTS ANALYSIS MACHINE HUMAN BODY ELEMENTS ANALYSIS EQUIPMENT, APPLIES THE ACCURATE MEASUREMENTS OF AVR MICROCOMPUTER CONTROLLER BASE ON NEW STATIC METHOD DXA, ANALYSIS HUMAN ELEMENTS, FAT WEIGHT BMI (BODY MASS INDEX), NON-FAT AND OTHER HEALTH INDICATORS THROUGH MULTI-FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS METHOD (MFBIA). ALLOW YOU TO LOOSE WEIGHT EFFECTIVELY ON A SCIENTIFIC BASIS. WHICH IS CONSIDERED AS AN EPOCH-MAKING RESULT OF THE HEALTH INDUSTRY. IF YOU ARE A HEALTH CONSULTANT ,IT CAN PROVIDE AN INDEPENDENT ANALYSIS OF HEALTH DATA FOR EACH TEST. APPLICABLE FOR FITNESS CENTERS , MEDICAL CENTERS, SENIOR CLUBS. SUPPORTING PROJECTS OF WEIGHT LOSS . DATA FUNCTION: ANALYSES THE SLIMMING EFFECT TO PROVIDE A THE SLIMMING TREATMENT, ON A SCIENTIFIC BASIS. THE REASONABLE WEIGHT CONTROL HELPS MAINTAIN THE BEST PHYSICAL STRENGTH AND DISTINGUISH BETWEEN MUSCLE TYPE, OVERWEIGHT AND/OR OBESITY. FINDS THE BEST CONTROL WEIGHT METHOD. SUGGESTS DIRECT ENERGY INTAKE AND DIETARY INTAKE OF NUTRIENTS IN CORRECT PROPORTIONS. GUIDING NUTRITION GUIDELINES AND RECOVERY MEASURES TO PROMOTE SYNTHESIS OF MUSCLES MASS. EVALUATION OF THE REHABILITATION TREATMENT EFFECT, GUIDING SCIENTIFIC BODY SLIMMING WITH SCIENTIFIC TRAINING, REHABILITATION, AND NUTRITION. DETECTS THE STATUS OF THE PHYSICAL AND HEALTH OF TEENAGERS, DEVELOPING FOR THEM A FEASIBLE EXERCISE PROGRAM. CLARIFY THE NUTRITION, AND OTHER FACTORS ON BODY COMPOSITION EFFECTS. SUGGEST INCIDENCE OF IMPORTANT PREVENTIVE MEASURES TO ATTEMPT TO REDUCE DIABETES. ADVANTAGES: WITH CE CERTIFICATE IT IS MULTI-FREQUENCY, INCLUDES 20KHz, 50KHz, AND 100KHz. IT CAN MEASURE YOUR WHOLE BODY. IT INCLUDES AN INBUILT MICRO THERMAL PRINTER AND HP COLOR PRINTER AT NO CHARGE THE ELECTRODE METHOD IS 8 POINT CONTACT ELECTRODE WHICH MAKES THE MEASUREMENT MORE ACCURATE. IT ANALYSIS A TOTAL OF 25 VALUE OF BODY COMPOSITIONS AND PROVIDES A HIGHLY ACCURATE WHOLE BODY ANALYSIS IN UNDER 10 SECONDS. THE COMPUTER HAS WIFI AND WIRELESS CONNECTION CAPABILITY SPECIFICATION: INPUT: 220V, 60Hz POWER: 53VA RATED CURRENT: <180μA SIZE: 390mm X 530mm x 1000mm QUANTITY: 1 Learn More -
T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENTREFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More -
T-6546 PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKREFERENCE NUMBER: T-6546PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKINTRODUCTIONMEDICAL SURGICAL MASK PARTICLE FILTRATION EFFICIENCY PFE TESTER IS SUITABLE FOR MEDICAL INSTRUMENT INSPECTION CENTER, SAFETY PROTECTION INSPECTION CENTER, LABOR PROTECTION INSPECTION CENTER, DRUG INSPECTION CENTER, DISEASE PREVENTION AND CONTROL CENTER, TEXTILE INSPECTION CENTER, HOSPITAL, MASK AND RESPIRATOR MANUFACTURERS, ETC.FEATURESTHE PFE TESTER FOR PARTICLE FILTRATION EFFICIENCY OF SURGICAL MASKS IS EQUIPPED WITH A SPECIAL SALT AEROSOL GENERATOR, WHICH CAN PRODUCE AEROSOLS WITH SPECIFIC PARTICLE SIZE AND CONCENTRATION.EQUIPPED WITH A SERIES OF SPECIAL FIXTURE, SUITABLE FOR THE DETECTION OF ALL KINDS OF MASKS.BUILT-IN HIGH LIFE PHOTOMETER MODULE, SAMPLING TIME ACCUMULATION, PROMPT LIGHT CLEANING.AUTOMATIC CONTROL OF AEROSOL GENERATION, AUTOMATIC CALCULATION OF CAPTURE EFFICIENCY AND MASK AIRFLOW RESISTANCE, REDUCE HUMAN INTERVENTION.BUILT-IN HIGH PRECISION ELECTRONIC FLOWMETER AND HIGH PERFORMANCE SAMPLING PUMP TO ENSURE FLOW STABILITY.PARAMETERTEST FLOW: PARAMETER RANGE: (5 ~ 100) L/MIN; RESOLUTION: (5 ~ 100) L/MIN;MAXIMUM ALLOWABLE ERROR: ±1%PRESSURE DETECTION RANGE: PARAMETER RANGE: (0 ~ 2500) PA; RESOLUTION: 0.1PA; MAXIMUM ALLOWABLE ERROR: ±1%CONCENTRATION DETECTION RANGE: PARAMETER RANGE: (0.001 ~ 100) 0 G/L;DETECTION ACCURACY: 1% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100%DETECTION REPEATABILITY: 5% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100% MEDIAN DIAMETER OF SALT AEROSOL PARTICLES (CMD): (0.075±0.02)MMEDIAN AEROSOL PARTICLE NUMBER DIAMETER (CMD) (OPTIONAL): (0.185±0.02) MOPERATING TEMPERATURE: 20±5CLearn MoreINSTRUMENT NOISE: <60DB(A)POWER SUPPLY: AC220V±10%, 50HZMAIN MACHINE SIZE: (LENGTH 700 X WIDTH 720 X HEIGHT 1450) mmQUANTITY: 1 -
T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More