Search results for: 'air com'
- Related search terms
- Complete
- Complete p
- air+in
- Comple
- complete+a
-
TT-4992 GENERAL ELECTRIC 7EA GTG PACKAGED POWER PLANT, 60 Hz, YEAR 2014TT-4992 GENERAL ELECTRIC 7EA GTG PACKAGED POWER PLANT, 60 Hz, YEAR 2014 GENERAL ELECTRIC 7EA GTG PACKAGED POWER PLANT YEAR: 2014 CONDITION DETAILS: NEVER USED OPERATIONAL STATUS: DISCONNECTED QUANTITY: 1 Learn More -
TT-1508 SIEMENS SGT-800 GENERATOR SET, 50 Hz, 47.5 MWTT-1508 SIEMENS SGT-800 GENERATOR SET, 50 Hz, 47.5 MW GAS TURBINE GENERATOR PLANT THIS USED SGT GENSET HAS FORMERLY BEEN USED BY A PAPER FACTORY AND HAS BEEN PROFESSIONALLY DISMANTLED AND PACKED BY THE ORIGINAL MANUFACTURER SIEMENS IN MARCH 2022. QUANTITY: 2 SETS Learn More -
V-2170 GENERAL ELECTRIC (GE) STEAM TURBINE 615MW FOR PRODUCING ELECTRICITY STEAM TURBINE ONLY IS BEING OFFERED FOR SALEV-2170 GENERAL ELECTRIC (GE) STEAM TURBINE 615MW FOR PRODUCING ELECTRICITY STEAM TURBINE ONLY IS BEING OFFERED FOR SALE UNIT DETAILS: TURBINE SERIAL NUMBER: 270T764 GENERATOR SERIAL NUMBER: 290T764 RPM: 3600 TURBINE: DESIGN CODE: G12 CONTROL SYSTEM: MARK VI STAGES: 22 LSB LENGTH: 30” INITIAL STEAM TEMPERATURE: 1050F INITIAL STEAM PRESSURE: 3,515 PSIA EXHAUST PRESSURE: 3.45 HGA GENERATOR: CODE: L2D RATING: 750,000 KVA VOLTAGE: 21,000 POWER FACTOR: .9 AMPS: 20,620 EXCITER RATING/VOLTS: 605 AMOUNT OF STEAM NEEDED: 4,200,000 TONS PER HOUR, 3500 PSI YEAR OF THE MACHINE: MANUFACTURED BETWEEN 2009 AND 2016 (IT TAKES 5 TO 6 YEARS TO PRODUCE IT) TYPE OF STEAM TURBINE: IS IT A BACK PRESSURE OR EXTRACTION STEAM TURBINE TO PRODUCE LOW PRESSURE AND MEDIUM PRESSURE STEAM? [ANSWER] LOW AND MEDIUM STEAM PRESSURES IN PSI: [ANSWER] AMOUNT OF STEAM AVAILABLE FROM EACH PRESSURE LEVEL (IN POUNDS OR TONS): [ANSWER] SHIPPING DIMENSIONS: IT WILL OCCUPY A BULK SPACE FOR APPROXIMATELY 2500 TONS WEIGHT. IN ESSENCE, 25,000 TON SHIP NEEDS TO BE ENGAGED AND MOVING. QUANTITY: 1 Learn More -
TT-3447 ATLAS COPCO RD20II AND T3W OIL RIG, YEAR 2013TT-3447 ATLAS COPCO RD20II AND T3W OIL RIG, YEAR 2013 ITEM 001 ATLAS COPCO RD20 RANGER II YEAR: 2013 HOURS: 86 HOURS ITEM 002 ATLAS COPCO T3W YEAR: 2013 HOURS: 57.3 HOURS KMS: 1418.6 KM Learn More -
TT-2077 GE FRAME 7EA 86.5MW POWER GENERATION SET – NEW, 60 Hz, YEAR 2014TT-2077 GE FRAME 7EA 86.5MW POWER GENERATION SET – NEW, 60 Hz, YEAR 2014 CONDITION: NEW NEVER USED MANUFACTURED: GENERAL ELECTRIC YEAR 2014 AVAILABILITY: DISCONNECTED / IMMEDIATE Learn More -
TT-2952 INGERSOLL-RAND RD20 II TOP DRIVE/AIR ROTARY DRILLING UNIT, YEAR 2001TT-2952 INGERSOLL-RAND RD20 II TOP DRIVE/AIR ROTARY DRILLING UNIT, YEAR 2001 INGERSOLL-RAND RD20 II TOP DRIVE/AIR ROTARY DRILLING UNIT YEAR 2001 TYPE: STANDARD BRAND: INGERSOLL RAND CATEGORY: DRILLING EQUIPMENT IN STOCK: YES TYPE: USED CONDITION: GOOD VERSATILITY: THE RD20 II IS A HIGHLY VERSATILE DRILLING RIG THAT CAN BE USED FOR A WIDE RANGE OF DRILLING APPLICATIONS, INCLUDING OIL AND GAS EXPLORATION, WATER WELL DRILLING, GEOTHERMAL DRILLING, AND MINING EXPLORATION. ITS ADAPTABILITY ALLOWS OPERATORS TO USE THE RIG IN DIFFERENT ENVIRONMENTS AND DRILLING CONDITIONS. QUANTITY: 1 Learn More -
J-4810 FUNG CHANG INDUSTRIAL RASCHEL KNITTING LINES FOR PLASTIC BAGS, YEAR 2020J-4810 FUNG CHANG INDUSTRIAL RASCHEL KNITTING LINES FOR PLASTIC BAGS, YEAR 2020 MAKE: FUNG CHANG INDUSTRIAL CO, LTD YEAR: 2020 CONSISTING OF 2 RASCHEL KNITTING LINES: ITEM 001 RASCHEL KNITTING LINE WITH AUTO-CUTTING DEVICE (COMPLETE LINE FOR ONION / POTATOES / FIRE LOG NETS), YEAR 2020 QUANTITY: 1 LINE ITEM 002 RASCHEL KNITTING LINE WITH AUTO-CUTTING DEVICE (COMPLETE LINE FOR ONION / POTATOES / FIRE LOG NETS), YEAR 2020 QUANTITY: 1 LINE Learn More -
TT-1767 TAURUS T60 TURBINES, 50-60Hz, YEAR 2012TT-1767 TAURUS T60 TURBINES, 50-60Hz, YEAR 2012 TAURUS T60 TURBINES TYPE: STANDARD BRAND: SOLAR CATEGORY: ENGINES/GENERATORS/MOTORS/TRANSMISSIONS SUBCATEGORY: TURBINE TYPE: NEW SURPLUS CONDITION: EXCELLENT 50Hz NATURAL GAS (CAN CONVERT TO DUAL DIESEL/NG WITH ADDITIONAL CHARGES) YEAR: 2012 Learn More -
T-7951 PRE AND FINISH – NEEDLER, WIDTH 2800mm TO 2900mmT-7951PRE AND FINISH – NEEDLER, WIDTH 2800mm TO 2900mm ITEM 001 PRE - NEEDLER QUANTITY: 1 ITEM 002 FINISH - NEEDLER QUANTITY: 1 Learn More -
1000 L STABILITY CHAMBERREFERENCE NUMBER: A-2492 1000 L STABILITY CHAMBER SPECIFICATIONS: INNER CHAMBER SIZE: 1 X 1 X 1 mm EXTERNAL DIMENSION: 1.2 X 1.97 X 2.17 mm TEMPERATURE RANGE: 70 TO 180°C HUMIDITY RANGE: 10% TO 98% RH, WHEN THE TEMPERATURE IS ABOVE 60°C, THE HUMIDITY CAN ACHIEVE 10% RH TEMPERATURE & HUMIDITY FLUCTUATION: ±0.2℃, ±0.5% RH INDICATION RESOLUTION: 0.01℃, 0.1% RH TEMPERATURE & HUMIDITY UNIFORMITY: ±2℃, ±3% RH (TESTED WITH THE EMPTY CHAMBER, 30 MINUTES AFTER STABILIZATION) HEAT UP AND COOL DOWN TIME: HEATING RATE: AVERAGE 3 ℃/MINUTES; COOLING RATE: AVERAGE 1 ℃/MINUTE (UNLOADED TEST) MATERIAL: INNER CHAMBER: SUS#304 STAINLESS STEEL EXTERIOR STRUCTURE: STAINLESS STEEL PLATE + POWDER COATED INSULATION: GLASS WOOL & PUF PERSPIRATION RESISTANT: K STYLE TUBE ACCESSORIES • TEMPERATURE RESISTANT SILICONE GASKET: 1 PC • CABLE PORT:1 PC; OD: 100 mm • WINDOW LIGHT: 1 PC • MULTIPANE VIEW WINDOW: 1 PC • LOADING SHELVES: 2 PCS REFRIGERATION & HEATING SYSTEM • ORIGINAL IMPORTED HIGH EFFICIENCY COMPRESSOR • AIR COOLING CONDENSER • FIN – TUBE HEATER • ORIGINAL IMPORTED SOLENOID VALVES • INNER SPIRAL K – TYPE REFRIGERANT COPPER TUBE • U – TYPE FINNED ELECTRO - THERMAL TUBE • HEATING & COOLING SYSTEMS SEPARATED • SINGLE STAGE REFRIGERATING SYSTEM HUMIDIFYING & DEHUMIDIFYING SYSTEM • ELECTRIC & BYTE TYPE HUMIDIFYING SYSTEM • STAINLESS STEEL HUMIDIFYING BARREL WITH VIEW WINDOW FOR WATER LEVEL • ADP DEHUMIDIFYING WAY • OVER – TEMPERATURE AND OVERFLOW PROTECTION UNITS • HUMIDIFYING & DEHUMIDIFYING SYSTEMS SEPARATED CIRCLING & DRAIN SYSTEM • CENTRIFUGAL FAN & IMPORTED MOTOR • REVERSE UNIFLOW (AIR FLOW DIRECTION) • FLOW – THROWS WIND • DRAIN SYSTEM USES SWIRL TYPE OUTLET AND U – TRAP DEPOSITION UNIT PROGRAMABLE MICRO COMPUTER LCD TOUCH CONTROLLER • PROGRAMMABLE TOUCH CONTROLLER, USER - FRIENDLY, STABLE AND EASY USE • PROGRAMS: 99 SEGMENTS PER PROGRAM, 120 PROGRAMS, 120 CYCLING PER PROGRAM • PID & SSR CONTROL WAY, STABLE AND EASY USE • HAVE SLOP CONTROL FUNCTION FOR HEATING & COOLING, LINKED PTNS CAN BE EXECUTED • PID AUTOMATIC CALCULATION • MICRO COMPUTER MULTI FUNCTION CONTROLLER, MAIN COMPONENTS ’DATA AUTOMATICALLY OUTPUT INCLUDING COMPRESSORS, SOLENOIDS, HEATING UNITS, ETC • ERRORS OF MAIN COMPONENTS APPEAR ON THE LCD PANEL • THE BRIGHTNESS OF THE LCD PANEL CAN BE ADJUSTED • TIME SEQUENCE CONTROL INTERFACE RELAYS HAVE 3 GROUPS WHICH MANAGE THE OUTPUT OF OUTSIDE LOGIC UNITS INCLUDING SIGNAL, MECHANICAL AND POWER, ETC • PROGRAMS AUTO – SAVE FUNCTION IF POWER CUT OFF SUDDENLY • HAVE HOLD & ADV BUTTONS INPROGRAMS • AUTOMATICALLY SET THE HIGH & LOW TEMPERATURE LIMITS AFTER PROGRAMS SET • PASSWORD SET FUNCTION • SD CARD SLOT, 2 GB SD CARD, RS232 OR ETHERNET (RJ45) OPERATING ENVIRONMENT • AMBIENT TEMPERATURE: +25℃ (2) RH ≤85% PROTECTION • ELECTRICITY LEAK PROTECTION • LIGHTNING STRIKE PROTECTION, ZRN LIGHTNING ARRESTER INSIDE THE CONTROLLER • SENSOR DATES TRANSFERRED INSIDE THE MICRO COMPUTER • TEMP. SENSORS TO OPEN CIRCUIT OR SHORT CIRCUIT (+ - OVER) • THE FIRST LEVEL OVER TEMPERATURE PROTECTION • ERROR DETECTED UNITS • THE SECOND LEVEL OVER TEMPERATURE PROTECTION TO ELECTRONIC OVER - TEMP PROTECTION UNIT • THE THIRD LEVEL OVER - TEMPERATURE PROTECTION • COMPRESSOR PROTECTION TO REFRIGERANTS PRESSURE PROTECTION & OVERLOAD PROTECTION. • EXTENDED PROTECTION UNIT TO TWO SUPPLETIVE PORTS • ERROR PROTECTION TO POWER CUT OFF, ERROR REPORTS SHOWN IN LCD PANEL AND AUDIBLE ALARM STARTS • DYNAMIC HIGH AND LOW TEMPERATURE PROTECTION • AMBIENT TEMPERATURE PROTECTION TO THE INNER CHAMBER AND SPECIMENS AUTOMATICALLY RETURN BACK TO AMBIENT TEMPERATURE AFTER THE OPERATION STOP SAFETY PROTECTION • NON-FUSE PROTECTION SWITCH • OVERHEAT ALARM PROTECTION • COMPRESSOR OVERLOAD PROTECTION • PHASE SEQUENCE PROTECTION • MOTOR OVER TO CURRENT PROTECTION Learn More