Search results for: 'steam'
- Related search terms
- steam mach
- steam+ca
- steam+ca'
- steam 2'
- STEAM A
-
TT-7913 SIEMENS SST-300 COMPLETE STEAM POWER GENERATOR, 20.29 MW, YEAR 2021, 50HzTT-7913 SIEMENS SST-300 COMPLETE STEAM POWER GENERATOR, 20.29 MW, YEAR 2021, 50Hz 1. UNPACKED - STILL BOXED AND CRATED - COMPLETE PLANT 2. NEW UNUSED 3. MODEL: SIEMENS SST-300 4. YEAR OF MANUFACTURE: 2021 Learn More -
K-8158 COAL FIRED STEAM POWER PLANT 330 MW YEAR 1983K-8158 COAL FIRED STEAM POWER PLANT 330 MW YEAR 1983
COAL FIRED STEAM POWER PLANT 330 MW
PLANT FOR RELOCATION
EQUIPMENT AND AUXILIARIES IN EXCELLENT CONDITIONSUMMARY OF MAIN ADVANTAGES:
THE STEAM PLANT IS AVAILABLE NOW AND CAN BE REINSTALLED IN SHORT TIME
POWER AVAILABLE IN SHORT TIME
THE EQUIPMENT IS OFFERED AT ATTRACTIVE CONDITIONS
LOW INVESTMENT COST
THE MAIN EQUIPMENT IS BASED ON STATE OF THE ART DESIGN & EMISSION CONTROL
COMMERCIAL LIFE TIME FOR MANY YEARS TO COME
RELOCATION IN COOPERATION WITH OEM SUPERVISING AND GUARANTEES OVERALL CONCEPTTECHNICAL DATA OF BOILER:
OEM
STEAM OUTPUT DESIGN PRESSURE LIVE STEAM REHEAT TEMP FUEL980 T/H
203 BAR
184 BAR / GRAD CBROWN COAL, APPROXIMATELY 9,000 KJ/KG
HARD COAL POSSIBLE AS WELL (24,000 - 28,000 KJ/KG)CONSUMPTION APPROXIMATELY 280 T/H AT FULL LOAD WITH BROWN COAL
APPROXIMATELY 110 T/H AT FULL LOAD WITH HARD COALGRINDING MILLS: 6
EMISSION SO2 200 MG/NM3 X 200 MG/NM3 ASHES 50 MG/NM3 EXHAUST TEMP 70°C
TECHNICAL DATA STEAM TURBINE:
OEM
OUTPUT
LIVE STEAM: 330/345 MW, 177.5 BAR, 535°CGENERAL REMARKS:
PLANT HAS GONE IN COMMERCIAL OPERATION IN 1983
PLANT AND EQUIPMENT HAS BEEN IN OPERATION BASICALLY DURING THE WINTER PERIOD AND HAS 84,300 HOURS ACCUMULATED ONLY
ALL EQUIPMENT IS IN EXCELLENT CONDITION AND PROFESSIONALLY PRESERVEDENTIRE PLANT WITH ALL AUXILIARIES IS AVAILABLE FOR RELOCATION
SCOPE AND CONDITIONS:
DISASSEMBLED, PACKED, AND SHIPPED OR TURNKEY SOLUTION CAN BE NEGOTIATED
RELOCATION WILL BE INCOORDINATION WITH THE OEM WHO IS WILLING TO GIVE A CERTAIN LEVEL OF GUARANTEE FOR THE RELOCATED PLANTQUANTITY: 1
Learn More -
TT-6997 ELLIOTT STEAM TURBINE PAIRED WITH HYUNDAI-IDEAL ELECTRIC GENERATOR SET - NEW, YEAR 2016TT-6997 ELLIOTT STEAM TURBINE PAIRED WITH HYUNDAI-IDEAL ELECTRIC GENERATOR SET - NEW, YEAR 2016 1. ELLIOTT STEAM TURBINE PAIRED WITH HYUNDAI-IDEAL ELECTRIC GENERATOR SET 2. NEW, NEVER USED 3. MODEL: 2 DYR6 4. CAPACITY: 7MW QUANTITY: 1 Learn More -
TT-6696 DRESSER-RAND GMBH STEAM TURBINE DR 2TA, 3,750 KWTT-6696 DRESSER-RAND GMBH STEAM TURBINE DR 2TA, 3,750 KW 1. DRESSER-RAND GMBH STEAM TURBINE DR 2TA 2. UNUSED TURBINE 3. MAX. POWER OUTPUT: 3,750 KW / 5,000 HP QUANTITY: 1 Learn More -
TT-2148 MAN TURBO 16 MW STEAM TURBINE GENERATOR ASSEMBLY MODEL MARC4-B00TT-2148 MAN TURBO 16 MW STEAM TURBINE GENERATOR ASSEMBLY MODEL MARC4-B00 MAN TURBO 16 MW STEAM TURBINE GENERATOR ASSEMBLY MODEL MARC4-B00 USED QUANTITY: 1 Learn More -
TT-6830 SIEMENS/RENTECH CONDENSING STEAM TURBINE-GENERATOR PACKAGE, 24.5MW, UNUSED, YEAR 2013 TO 2014, 50 HzTT-6830 SIEMENS/RENTECH CONDENSING STEAM TURBINE-GENERATOR PACKAGE, 24.5MW, UNUSED, YEAR 2013 TO 2014, 50 Hz ALREADY DISMANTLED THE PACKAGE AND CAN MAKE IT AVAILABLE FOR DELIVERY IN 2 WEEKS Learn More -
TT-3544 SALVADE CONTINUOUS STEAM AGER STEAMER, WORKING WIDTH 3400mm, YEAR 2008TT-3544 SALVADE CONTINUOUS STEAM AGER STEAMER, WORKING WIDTH 3400mm, YEAR 2008 BRAND: SALVADE MODEL: VPM YEAR OF CONSTRUCTION: 2008 QUANTITY: 1 Learn More -
M-4010 10 MW BIOGAS TO STEAM CONGENERATION PLANT – 10 MEGAWATTSREFERENCE NUMBER: M-4010
10 MW BIOGAS TO STEAM CONGENERATION PLANT – 10 MEGAWATTS
10 MW BIOGAS-FIRED COGENERATION PLANT
LATE MODEL, EXCELLENT CONDITION
INCLUDES BOILER, STEAM TURBINE, GENERATOR AND CONDENSER
CAPABLE OF CONVERTING METHANE, LANDFILL GAS, BIOGAS OR NATURAL GAS INTO ELECTRICITY
COMPLETE WITH ALL SUPPORT EQUIPMENT, INCLUDING PUMPS, WATER SYSTEMS, BLOWERS, ETC.
COMPLETE CONTROL ROOM AVAILABLE WITH OPERATIONAL CONTROL PANELS FEATURING CONTROLS BY PANALARM, FOXBORO, BENTLY NEVADA AND BASLER
STARTERS AND SWITCH GEAR BY SIEMENS
BOILER:
125,000 LBS/HR @ 725 PSI DELTAK FIRE TUBE STEAM BOILER
16,189 SQ. FT. HEATING SURFACE
STEAM TURBINE:
101,000 LBS/HR @ 600 PSI TERRY MULTI-STAGE CONDENSING STEAM TURBINE
INCLUDES WOODWARD GOVERNOR AND TACKE GEAR REDUCER
GENERATOR:
10,200 KW IDEAL ELECTRIC
1,800 RPM, 60 HZ
INCLUDES BRUSHLESS EXCITER
CONDENSER:
7,809 SQ. FT. GRAHAM SHELL AND TUBE HEAT EXCHANGER
CS AND ADMIRALTY BRASS CONSTRUCTION
88,100 LBS/HR EXHAUST
86 MM BTU/HR DUTY
Learn More -
TT-7348 SIEMENS SST-400 STEAM TURBINE GENERATOR PACKAGE - NEW, 24.5 MW, YEAR 2014, 50 HzTT-7348 SIEMENS SST-400 STEAM TURBINE GENERATOR PACKAGE - NEW, 24.5 MW, YEAR 2014, 50 Hz 1. SIEMENS SST-400 STEAM TURBINE GENERATOR PACKAGE 2. BRAND SIEMENS 3. MODEL SST400 4. TYPE GAS TURBINES QUANTITY: 1 Learn More -
TT-7324 CONDENSING STEAM TURBINE-GENERATOR PACKAGE, 50Hz, 24.5MWTT-7324 CONDENSING STEAM TURBINE-GENERATOR PACKAGE, 50Hz, 24.5MW 1. CONDENSING STEAM TURBO-GENERATOR PACKAGE 2. 50Hz/11KV 3. 24.5 MW 4. UNUSED QUANTITY: 1 Learn More