Superba, TVP, 1982, Heat Setting Line, 2 Tunnels, 24-End Creel

Description

  1. Overview
    1. Inventory number: E-1261
    2. Six Superba heat set machines available
    3. Machines can be separated with individual controls for an additional charge, for a total of six machines
  2. Superba I (Two Tunnels)
    1. Tunnel I: TVP 25-108/703-12G, year 1982, National Board No. 303
    2. 36-end creel
    3. Tunnel set up to run 24 ends
    4. Line entrance (common operator panel and entrance section with Tunnel II) coiler
    5. Superba pre-steamer with three circulating fans and control system
    6. Superba cooling fan
    7. Tunnel entrance section
    8. Three meter dead zone
    9. Two-meter entrance cooling section with two circulating fans
    10. Six-meter heat set section with CBS
    11. Two-meter exit cooling section with two circulating fans
    12. Tunnel exit
    13. Two Superba cooling fans
    14. Superba yarn takeoff system
    15. Superba MAT 2S accumulator, #596-10
    16. Belmont 24 spindle autodoff winder, take up on carpet tubes
    17. SamsoMatic tunnel control system
  3. Superba I Tunnel II
    1. Tunnel II: TVP 25-108/703-12D, year 1982, National Board No. 304
    2. 24-end creel
    3. Line entrance (common operator panel and entrance section with Tunnel I) coiler
    4. Superba pre-steamer with three circulating fans and control system
    5. Superba cooling fan
    6. Tunnel entrance
    7. Two-meter entrance cooling section with two circulating fans
    8. Nine-meter heat set section with CBS
    9. Two meter exit-cooling section
    10. Tunnel exit
    11. Two Superba cooling fans
    12. Superba yarn takeoff system
    13. Superba B3 manual doff winder with take up on carpet tubes
    14. SamsoMatic tunnel control system
  4. Superba II (Two Tunnels)
    1. Tunnel I: TVP 30-504/852-12G, year 1985, National Board No. 415
    2. 24-end creel
    3. Line entrance (common operator panel and entrance section with Tunnel II) coiler
    4. Superba pre-steamer with three circulating fans and control system
    5. Superba cooling fan
    6. Tunnel entrance
    7. Three meter dead zone
    8. Two-meter entrance cooling section with one circulating fan
    9. Six-meter heat set section with CBS
    10. Two-meter exit cooling section with one circulating fan
    11. Tunnel exit
    12. Two Superba exit-cooling fans
    13. Superba yarn takeoff system
    14. Superba B3 manual doff winder with take up on carpet tubes
    15. Superba ARG tunnel control system #431-3
  5. Superba II Tunnel II
    1. Tunnel II: TVP 30-504/852-12D, year 1985, National Board No. 414
    2. 24-end creel
    3. Line entrance (common operator panel and entrance section with Tunnel I) coiler
    4. Superba pre-steamer with three circulating fans and control system
    5. Superba entrance cooling fan
    6. Tunnel entrance
    7. Three meter dead zone
    8. Two-meter entrance cooling section with one circulating fan
    9. Six-meter heat set section with CBS
    10. Two-meter exit cooling section with one circulating fan
    11. Tunnel exit
    12. Two Superba cooling fans
    13. Superba yarn takeoff system
    14. Superba B3 manual doff winder with take up on carpet tubes
    15. SamsoMatic tunnel control system
  6. Superba III (Two Tunnels)
    1. Tunnel I: TVP 24-102/702-1G, year 1981, National Board No. 257
    2. 36-end creel
    3. Line set up for 36-end production
    4. Line entrance (common operator panel and entrance section with Tunnel II) coiler
    5. Superba pre-steamer with three circulating fans and control system
    6. Superba entrance cooling fan
    7. Tunnel entrance section
    8. Three meter dead zone
    9. Two-meter entrance cooling section with two circulating fans
    10. Six-meter heat set section with CBS
    11. Tunnel exit
    12. Two Superba exit-cooling fans
    13. Superb yarn take-up system
    14. No winder
    15. Superba ARG tunnel control system (no number)
  7. Superba III Tunnel II
    1. Tunnel II: TVP 24-102/702-1D, year 1982, National Board No. 258
    2. 36-end creel
    3. Line set up for 24-end production
    4. Line entrance (common operator panel and entrance section with Tunnel I) coiler
    5. Superba pre-steamer with three circulating fans and control system
    6. Superba entrance cooling fan
    7. Tunnel entrance section
    8. Three meter dead zone
    9. Two-meter entrance cooling section with two circulating fans
    10. Six-meter heat set section with CBS
    11. Two-meter exit cooling section with two circulating fans
    12. Tunnel exit
    13. Two Superba exit-cooling fans
    14. Superba yarn take-off system
    15. Superba B3 manual doff winder with take up on carpet tubes
    16. SamsoMatic tunnel control system