Perkins, Diesel Generator Set, 2001

Description

  1. Overview
    1. Listing quantity: 2.
    2. Inventory number: E-2093.
  2. 100 kW Perkins Genset
    1. Rated 100 kW at 1800 rpm.
    2. New condition, 0 hours since new in 2001.
    3. Includes control panel and auto start/stop option.
    4. Serial number U757275H.
    5. Reference 1000804-30C.
  3. 100 kW CD 100, Cat 3054 Enclosed Genset
    1. Enclosed with fuel tank base.
    2. Year 1995, only 3 hours since new in 2000.
    3. Includes control panel, 500 amp breaker, 120/208 VAC.
    4. Serial numbers 7AK01760 and UE08330.
    5. Reference 1000804-30C.
  4. 125 kW Allis Chalmers Generator Set
    1. Rated 125 kW at 1800 rpm.
    2. Serial number 14-02457.
    3. Reference 1250804-30C.
  5. 150 kW Cummins/Onan Diesel Generator Set
    1. 2002 year model.
    2. 24.7 total hours since new.
    3. Equipped with jacket water heater, electronic governor, 12-lead re-connectable generator, battery rack, detector 12 control panel, 300 amp mainline circuit breaker, quiet site 2 factory enclosure with exhaust system, and a 24-hour base fuel tank.
    4. Meets Tier 1 requirements.
    5. Reference RCYNN-29 and 1500804-29.
  6. 165 kW Caterpillar Diesel Generator Set
    1. Caterpillar model 3306TA diesel engine.
    2. Serial number 66D2868, arrangement number 7N3381.
    3. 3 phase, 60 hertz, 0.8 power factor, 1800 rpm.
    4. Brown Boveri generator, 12-lead reconnectable, currently set at 120/208 V, will change to 277/480 V if desired.
    5. 600 amp mainline circuit breaker, Woodward electronic governor, generator control panel, safety shutdown system.
    6. Skid mounted, radiator cooled.
    7. 24 hours since reconditioned and placed into standby service.
    8. Will be tested and serviced prior to shipping; in excellent running condition.
    9. Reference OAYN-24B and 1650604-24B.
  7. 700 kW Used Caterpillar 3508 DITA Generator Set
    1. Rated 700 kW at 1800 rpm.
    2. Skid mounted with engine driven radiator, 24-VAC electric starter, analog Enercon control panel with auto and manual start, electronic Woodward governor, jacket water heaters, and a 1200 amp mainline circuit breaker.
    3. Generator end: Marathon model 682FDR8074CG-W500W, serial number MM-3022573, 682 frame, 480 VAC, 3 lead, 60 Hz, 3-phase with voltage regulator.
    4. Engine serial number 23Z00434, arrangement number 7N8701.
    5. Late 1980s model with less than 1,000 total hours since new.
    6. Reference 7000804-30C.
  8. 750 kW Cummins/Onan Diesel Generator Set
    1. Pritchard Brown weatherproof type enclosure.
    2. Cummins diesel engine model KTA 38 G1, serial number 33124238.
    3. Model 750DFGR, serial number E930507952.
    4. 277/480 volt, 3 phase, 60 hertz, 0.8 power factor, 1800 rpm.
    5. Generator control panel, safety shutdown system, mainline circuit breaker, block heater, engine mounted radiator.
    6. Engine model KTA-38-G1.
    7. 528 total hours since new in 1993.
    8. Dealer serviced and certified in perfect operating condition, ready for immediate delivery.
    9. Reference YCYNN-24B and 7500804-24B.
  9. 1250 kW Caterpillar 3512 DITA Generator Set
    1. Rated 1250 kW at 1800 rpm standby.
    2. Sound attenuated weather resistant container, radiator, 2000 amp mainline circuit breaker, digital control panel, 1250 gallon fuel tank.
    3. Currently set up at 480 VAC, 60 Hz, 3 phase.
    4. Only 3,200 hours since new in 1996.
    5. Load tested.
    6. Serial number 24Z07780.
    7. Reference 1250804-30C.
  10. 1500 kW Kohler Diesel Generator Set
    1. 1989 year model.
    2. Under 500 total hours since new.
    3. Totally enclosed with Marathon generator, weatherproof enclosure, and base fuel tank with approximately 3000 gallon capacity.
    4. Includes analog control panel, mufflers, and mainline circuit breaker.
    5. Two units available.
    6. Reference CYNNN-39A and 1500804-39A.
  11. 1750 kW Enclosed Caterpillar 3516 DITA Generator Set
    1. Rated 1750 kW at 1800 rpm standby.
    2. Installed inside a shipping container.
    3. 3000 amp breaker, electric governor, 1250-gallon fuel tank, EMCP II control panel, 24 VAC electric start.
    4. In excellent operating condition.
    5. Set up at 480 VAC, 60 Hz, 3 phases.
    6. Only 2,570 hours since new in 1999.
    7. Engine serial number 25Z06409, arrangement number 107-7350, OT spec 2T6387.
    8. Load tested.
    9. Reference 1750804-30C.
  12. 2000 kW Standby Generator Set
    1. Skid mounted, power command control panel, radiator cooled, 24 VAC electric starter, block heater.
    2. Currently set up at 480 VAC, 60 Hz, 3 phase.
    3. California certified.
    4. Only 190 hours since new in 2001.
    5. Serial number C010218471.
    6. Reference 2000804-30C.