Description Overview Inventory number: E-3412 Two ABB Stal Laval gas turbine generators, model GT35, upgraded to 16 MW each To be removed from offshore platform Frigg TCP2 Dual fuel system on both turbines Specifications Manufacturer: ABB Stal Laval Type: GT 35 Power output: 16 MW each Original installation year: 1981 Turbines changed from B-version to C-version in 1994 due to larger power requirements Old relays control system Operating History Turbine "A" permanently stopped late 2004 (not required any more) Turbine "B" permanently stopped late 2003 (fault on generator stator windings) Total running time for Stal Laval "A" generator: 110,173 hours; turbine (new version): 58,093 hours Total running time for Stal Laval "B" generator: 98,086 hours; turbine (new version): 45,026 hours Service and Inspection Last service/inspection performed in 2001 (report available)