Sulzer, 16VZAV40S, 1989, 10.56 MW, 10 kV, 50 Hz, HFO Power Plant

Description

  1. Inventory Number
    1. E-3855
  2. Gas Generators For Sale
    1. 10.56 MW Sulzer power plant, HFO, 10 kV, 50 Hz, 1989
    2. Model: 16VZAV40S
    3. Approximately 30000 hours operated
    4. With Alsthom alternator, 10 kV, 50 Hz
    5. Dismantled and stored in warehouse
    6. Quantity: 2
  3. Additional Sulzer Power Plants
    1. 10.56 MW Sulzer power plant, HFO, 10 kV, 50 Hz, 1993
    2. Model: 16VZAV40S
    3. Approximately 35000 hours operated
    4. With Alsthom alternator, 10 kV, 50 Hz
    5. Still installed in plant site and operating in good condition
    6. Quantity: 1
  4. Another Sulzer Power Plant
    1. 11.52 MW Sulzer power plant, HFO, 10 kV, 50 Hz, 1995
    2. Model: 16VZAV40S
    3. Approximately 23000 hours operated
    4. With Alsthom alternator, 10 kV, 50 Hz
    5. Still installed in plant site and operating in good condition
    6. Quantity: 1
  5. 54 MW Man B&W HFO/DO Power Plant
    1. Year: 2002
    2. Configuration: (3) x 18 MW
    3. Engine: (3) x 18V48/60
    4. 11 kV, 50 Hz, 500 rpm
    5. Complete plant in very good condition
  6. 44 MW Man Power Plant
    1. HFO, 1991/1992
    2. Configuration: (4) x 10.89 MW, 11 kV, 50 Hz, 600 rpm
    3. Diesel engines: (4) x Man B&W AG, Germany, type 18V 40/45, rated output 10.89 MW @ 600 rpm
    4. Fuel oil consumption (current site condition): approximately 226 g/kWh
    5. First commissioned in 1991/1992 and operated until 31st December 2005
    6. In 2004, all engines were overhauled in accordance with Man services/technical requirements/instructions
    7. Total 24000 ~ 32000 hours used, 720 ~ 3600 hours used since overhaul in 2004
    8. Alternators: (4) x Siemens, type 1DK-5037-3DE05-E, rated capacity 13200 kVA, rated voltage/frequency 11 kV/50 Hz, 3-phase synchronous/brushless excitation, F class insulation
  7. Gas Turbine Generator Sets
    1. General Electric Company (GEC), model EM 610B
    2. 11.8 kV, 50 Hz
    3. Base/peak load: 58.0/61.9 MW
    4. Featured with: 13 stage compressor and 2-stage power turbine, single shaft supported by 2 bearings
    5. 3.3 kV motor starter
    6. 2-pole, 3 phase, 50 Hz, 11.8 kV, 58.0 MW air cooled generator
    7. Brushless exciter control system
    8. 11.8/132 kV, 64.0 MW OFAF generator transformer with on load tap changer
    9. 11800/433 V, 200 kW ONAN unit transformer
    10. 110 V AC inverter with battery/charger system
    11. Full package of auxiliaries including a workshop
    12. With a 2.08 MW black start diesel generator as option
    13. History: two (2) model EM 610B open cycle, single shaft, gas turbine sets manufactured by GEC gas turbines limited and commissioned in 1981
    14. Originally installed in 1980 and operated site until 1991, the gas turbine sets were relocated, re-commissioned at site and renamed as CG5 & CG6 in 1992
    15. Available for service through until 1998 when they became surplus to generation requirements
    16. Currently under preservation
    17. Operating hours/starts for CG5 and CG6 are 598/825 and 910/975 respectively
    18. Less than 1000 total hours running since new
    19. Quantity: 2
  8. 6.6 MW Sulzer HFO Package
    1. Engine: Sulzer 12ZA40/80, manufactured/installed in 1996/1997
    2. 6.6 MW (ISO)
    3. HFO (heavy fuel oil)
    4. Skid mounted
    5. Alternator: type GBD-10J-77550, manufactured in 1996, 7750 kVA, 50 Hz, 600 rpm, 6.3 kV
    6. History: installed in 1997, approximately 51000 total hours, 4000 hours since overhaul in 2004
    7. Plant last run in 2004
    8. Can run on HFO (991 kg/m3, 380 cSt)
    9. Alfa Laval fuel treatment equipment available
    10. 1385 kg/h or 201 g/kWh (at 42708 kJ/kg)
    11. Quantity: 1