Description Item E-6226 Inventory number: E-6226 Item 7020-23 Year: 1988 2 x 6 MW, 50 Hz ABB back pressure steam turbine 35 bar, 435 degrees Celsius 3 barg 20,000 - 30,000 hours Item 7022 Year: 1974 - 1970 2 x 2.2 MW, 50 Hz, 400 V + 11 kV Back pressure steam turbines 40 bar / 3 bar Item 7018 Year: 1990 97 MW ABB Stal 11.5 kV 50 Hz Condensing steam turbine generator 90 bar, 500 degrees C Decommissioned in 2002 Item 7016 Year: 1999, unused 50 MW, 60 Hz, 11.4 kV 1800 psi Condensing steam turbine Item 7015 Year: 2000 2 x 15 MW, 6.3 kV Condensing extraction steam turbine generators With 3 x CFB coal-fired boilers And up to 80 ton extraction steam at 180 psi Item 7009 Year: 2002, unused 2.1 MW, 60 Hz Elliott condensing steam turbine 460 - 700 psi inlet 0 - 15 psi out Item 6078 Year: 1997 1.7 MW, 50 Hz, 400 V KKK extraction-condensing steam turbine 25 bar, 405 degrees C inlet Extraction at 5 bar Complete with 12 ton/hr condenser Item 6077 Year: 1974 42 MW, 50 Hz, 13.8 kV ABB Stal back pressure turbine 108/3.9 bar With 11.7 bar extraction Plus gas/oil-fired boiler 30,000 hours Decommissioned in 2005 Item 6070-71 + Item 5082 Year: 1999 3 x 20-34 MW Siemens condensing/extraction and back pressure mechanical drive steam turbines To be decommissioned in August 2007 Item 6067 Year: 1978 2 x 10 MW, 60 Hz, 6.6 kV Fuji 60 bar extraction/condensing steam turbines Extractions at 16.2 and 3.95 b ara Plus Mitsubishi HFO fired boilers Item 6064 Year: 1987-1990 4 x 100 MW, 50 Hz, 10.5 kV AEG condensing steam turbines 84 bar 510 degrees C Plus coal-fired boilers Item 6063 Year: 2003, unused 135 MW, 60 Hz, 13.8 kV Fuji condensing steam turbine Item 6061 Year: 1990 20 MW, 60 Hz, 13.8 kV Shin Nippon condensing steam turbine Inlet 850 psi Extraction 28 tons at 230 psi and bleed at 90 psi 8500 hours since overhaul Item 6058 Year: 1986 1,330 kW, 50 Hz, 6.3 kV KKK 522 / 72 psi Back pressure Item 6051 Year: 1986 45 MW, 50 Hz, 11 kV 39.5 bar 480 degrees C Alstom condensing steam turbine Part of 2 on 1 frame 6 CCGT plant Item 6035 Year: 1995 1.1 MW, 50 Hz, AEG 400 psi condensing, firing wood waste With 8 ton boiler Item 6026 Year: 1992 6.8 MW, 50 Hz 30 bar, 400 degrees C Extraction 10 bar Item 4119 Year: 2002, unused 5 MW, 50 Hz, 11 kV Peter Brotherhood condensing steam turbine 435 psi 35 degrees C 29 ton/hr No condenser But with matching heat recovery boiler Item 338 Year: 2002 195 MW, 60 Hz Tandem compound exhaust Condensing reheat unused steam turbine 126 bar, 566 degrees C With 16.5 kV, 60 Hz 224 MVA alternator Item 101 Year: 1996 3 x 17 MW, 50 Hz, 5.5 kV 40 bar, 465 degrees C Condensing Alsthom steam turbine gen sets With condensers (78 ton/hr) With rewound alternators Item 5020 Year: 1979, unused 250 MW, 124 bar, 19 kV, 50 Hz Unused Mitsubishi steam turbine with oil-fired boiler Immaculately preserved