250 MW station comprising a single steam generator/steam turbine-alternator unit, designed to burn heavy fuel oil
Year 1975 and completed in 1979
The sudden unexpected and rapid rise in the price of oil in the 1970's, and a less than forecast demand for power, a decision was made to place the station in long term storage
Specifications
Make: Mitsubishi Heavy Industries Ltd, Japan
Type: Three casing, tandem compound, double flow, condensing, single reheat
Speed: 3,000 rpm
Nominal rating: 250,000 kW
Steam conditions at turbine stop valves: pressure 124 barg, temperature 538C
Design steam conditions are 124 bar gauge and 538C at the turbine stop valves
Reheat temperature is 538C and the design exhaust pressure is 74 mbar absolute
The nominal rating of the unit is 250,000 kW at a guaranteed steam flow rate of 748,660 kg/h through the stop valves at 124 bar gauge main steam pressure and 76 mbar absolute back pressure
Condition
Unused and in excellent condition
Placed in long term storage due to the sudden unexpected and rapid rise in the price of oil in the 1970's and less than forecast demand for power
Included
A full set of instruction and operation manuals are included
Scope available
An Indian company that specializes in the dismantling and re-assembly of this type of equipment has already visited the site and is familiar with the requirements to relocate it
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.