Coal fired boiler – steam turbine generator for sale
10,000 kW combined cycle plant composed of multiple generating sets and auxiliary equipment
Solar Taurus 70 Gas Turbine Generating Set
7.2 MW Solar Taurus 70 combustion turbine, natural gas, 3/60/4160V
Natural gas fueled, operated at 340 psig (can be converted to liquid or dual fuel)
Equipped with Solonox
Manufactured in 2001
Taken out of service in February 2008 and laid up by Solar
Always serviced under Solar maintenance contract
Turbine engine rotor, combustors, liners, injectors, and new bearings rebuilt to zero hours and installed July 2008
Mounted on heavy skid base frame in sound attenuated enclosure with main gearbox and 4160V generator with exciter and governor
Unit is electric start with synchronizing and paralleling switchgear, microprocessor based controls, air inlet filtration system, fire protection system, exhaust muffler, lubricating system, fuel handling system, vibration monitor, silencer and interconnecting ducting
Heat rate: 10,363 BTU/kW/hr
Exhaust temperature: 913°F
NOx level of emissions: 18.84 ppm or 0.069 lb/MM BTU
Approximate dimensions: 37 ft L x 8 ft 11 in W x 8 ft 11 in H
Approximate shipping weight: 106,000 lbs
E.R.I. Heat Recovery Steam Generator (HRSG)
170,000 lb/hr E.R.I. HRSG, 500 psig DP @ 650°F SH package watertube boiler series MFA-5-120-SH
Shop assembled 'A' type design composed of 54 in ID steam drum and (2) 24 in OD lower drums with 2 in OD tubes
Total heating surface: 29,877 sq ft
Boiler has a 2,022 sq ft ±650°F superheater and 22,351 sq ft economizer
Built in 2001 in accordance with ASME code and bearing NB and HSB stamping
Equipped with a Verloop package natural gas burner
Equipped with combustion safeguard controls, fuel trains, duct connection to combustion turbine having 954°F gas temperature input
Boiler will generate 27,400 lb/hr with its own burner, with inlet guillotine damper closed
Includes all standard boiler valve trim, regulators and controls, FD fans with motors, interconnecting piping and ductwork and valves
Approximate dimensions: 63 ft 5 in L x 11 ft W x 17 ft 5 in H
GE Steam Turbine Generating Set
3.5 MW GE extraction, back pressure (non-condensing) steam turbine generating set, 3/60/4160V
Multi-stage, multi-valve steam turbine presently operating at 400 psi @ 650°F with A.E. 125 psig and 30 lb BP exhaust
Direct connected to an 8000 KVA GE A.C. generator, 3/60/4160V with exciter, throttle valve, new electronic governor, oil lube system with pumps, new controls and switchgear
Present steam rate is ±30.3 lb/kW-hr
Unit was originally rated at 3500 kW as a straight condensing unit, operated at 190 psig @ 843.7°F, 1.5 in Hg abs exhaust at 4160V
This 12-stage multi-valve turbine was reworked and rerated to the above extraction, back pressure machine
The 10th stage was removed for the 30 lb back pressure feature
Turbine rows 1-7 were replaced with new, and some nozzles were replaced
The generator and rotor have been rewound, therefore upgraded in capacity with the addition of a new generator cooler
The original rotating exciter is stored on site, along with a 3500 sq ft Westinghouse surface condenser with circulating pumps, steam ejector, and lube oil filtering system
Also available and installed over the unit is a 25 ton x 20 ft wide floor controlled Shaw box crane
Single-bearing, closed coupled, direct connected to a Cat SR4B AC generator, 3/60/575-600V wye, 1250 KVA, 4-wire, 4-pole
Insulation class H, 130°C temperature rise / 40°C ambient
Equipped with digital voltage regulator, 1600 amp molded case circuit breaker, battery start system, remote annunciator, radiator cooling system with fuel oil cooler, battery charger, 1000 gallon base mounted tank, exhaust flex with muffler and relating components
Manufactured in 2001
Operated for 216 hours and shut down October 6, 2007
Fuel rate: 71.2 GPH
Approximate dimensions: 16 ft L x 7 ft 8 in W x 11 ft 1 in H
Approximate shipping weight: 28,000 lbs
Also available: dry step up transformer from 600V wye grounded to 4160V delta
Boiler Feed Pumps
Ingersoll-Rand centrifugal boiler feed pump: 250 GPM @ 1380 FTDH, horizontal, split, size and type 2CNTA-6, NPSH 29, packing metallic, glands smothering, 4 in/300 lb suction, 2.5 in/600 lb discharge, cast iron casing and impellers, steel shaft, fast coupling, connected to a 150 HP ODP motor, 3/60/575V, all mounted on common steel baseplate, manufactured in 1974, approximate dimensions 8 ft 6 in L x 3 ft W x 2 ft 7 in H, approximate shipping weight 4,000 lbs
Flowserve boiler feed pumps (3 units): 450 GPM @ 1380 FTDH, type 3WX-10A4, 4 in/300 lb suction, 3 in/600 lb discharge, connected through coupling to 200 HP motors, 3/60/575V @ 3540 RPM, all mounted on common steel base, manufactured in 2002, approximate dimensions 9 ft 8 in L x 3 ft W x 3 ft H, approximate shipping weight 3,000 lbs each
Water Treatment and Filter System
90-325 GPM GE Glegg water treatment and filter system, 50-100 psig normal feedwater pressure at 45-85°F
Composed of (1) multi-media filter unit, (2) counter-current softener units, (1) brine regeneration system
Equipped with Allen Bradley Micrologix 1500 controls for the water filtration/softener system
Approximate dimensions: 6 ft 11 1/4 in ID x 19 ft H
Approximate shipping weight: 18,000 lbs
Babcock and Wilcox Watertube Boiler
Disassembled and reconditioned 100,000 lb/hr Babcock and Wilcox 725 psig D.P. at 825°F superheat watertube boiler, type S-55, built in 1957 in accordance with ASME code and bearing NB and HSB stamping
2-drum bent-tube type Stirling composed of a completely water-cooled furnace with top-supported construction
Consisting of a 54 in steam drum and a 36 in lower drum, designed for a total heating surface of 11,106 sq ft, of which 1,686 sq ft are in the waterwalls
Fitted with (1) 1,470 sq ft pendant type, single-pass superheater
No insulation or casing is included
Valve trim consists of (3) 2 in safety valves (2 for boiler and 2 for superheater), (1) Bailey 2-element feedwater regulator with bypass arrangement, (1) water column with gauge glass, (3) 1.5 in Yarway tandem blowoff valves, (1) continuous blowdown valve, (1) 4 in feed stop and check valve, drain valves, (1) 6 in main outlet valve, Diamond or Copes sootblowers as well as relating valve trim, regulators, and controls
Also including full complement of Bailey metering combustion controls and instrumentation in a separate free standing panel
Offered with integral grid steel, some new main structural columns, buckstays, hoppers, access and inspection doors
Previously operated at a utility as a standby or backup unit, mainly on natural gas; the stoker system was rotated periodically to insure serviceability
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.