Description Overview Plant built in 1996 Heat recovery steam generator with a back-pressure turbine Condensation turbine with regulated low pressure Gas Turbine General Electric LM6000PA 39 MW Natural gas fuel Mark V control Year 1998 Gas Generator GEC Alsthom 48.76 MVA 11 kV, 50 Hz Year 1996 Heat Recovery Steam Generator Without post combustion Two pressures: 52 bar at 440 °C (44 ton/h), 4 bar at 188 °C (13 ton/h) 35 m by pass stack with hydraulic system Year 1996 Back Pressure Steam Turbine Siemens T-5452 4.5 MW, 6 kV, 50 Hz Inlet 52 bar at 440 °C, outlet 4 bar at 188 °C 44 steam ton/h Condensing Steam Turbine Allen S22-630 3.8 MW, 11 kV, 50 Hz Inlet 4 bar at 188 °C, 34 ton/h Year 1995 Generator Condensing Steam Turbine Indar LSA-710-L/A4 Year 1996 Included Associated auxiliary equipment also included