Description Overview The gas turbine engine gearbox alternator went through a major overhaul in 2008 Shut down in 2009 Gas Turbine Specifications 4950 kW 6300 V, 50 Hz Stand power: 4950 kWe G/L NGP RPM: 14944 @ 50 Hz IGV setting: 5.0 T5 Base: 1206F G/L set point full load: 1250F Alternator Specifications Make: Leroy Somer Type: SA 56 BUL85-4P IP: 21 Power: 4800 kW (6000 kVA) PF: 0.8 Volts: 6300 Amps: 549.8 RPM: 1500 @ 50 Hz Temp: 40 deg. C ambient Hrsg Specifications Make: Moiman SA Type: Cenerdor Vapor pressure: 13 kg/cm2 Volume: 33.5 cubic meters Temp service: 250 deg. C Included Equipment Air compressors Transformer gas compressor Refrigeration compressor