General Electric, Keeler, 1988, 17.6 MW, 13800V, Wood-Fired Biomass Power Plant

Description

  1. Overview
    1. Biomass power plant, wood-fired, field-erected, 17.6 mw at 13,800 volts
    2. Includes one 1988 Keeler 140,000 pph field-erected watertube boiler designed for 1050 psig at 950 f
    3. Includes one General Electric turbine generator system using 900 psig at 890 f superheated steam
    4. Includes one General Electric condenser
    5. Feedwater system with one deaerator and two feedwater pumps
  2. Boiler Specifications
    1. 1988 Keeler 140,000 pph, field-erected, watertube boiler
    2. Designed for 1050 psig at 950 f
    3. Equipped with welded wall construction and pendant type superheater
  3. Turbine Generator System
    1. General Electric turbine utilizing 900 psig at 890 f superheated steam
    2. General Electric generator designed to produce 17.6 mw of power at 13,800 volts
    3. One hydraulic system
    4. One General Electric condenser
    5. Two hot well pumps
    6. One lot of transmission switchgear
    7. One emergency diesel generator
  4. Feedwater System
    1. One deaerator
    2. One turbine driven feedwater pump
    3. One electric driven feedwater pump
    4. One lot of interconnecting pipe, valves and fittings
  5. Water Treatment System
    1. One water softener
    2. One demineralizer
    3. One acid tank
    4. One caustic tank
    5. Two condensate tanks