GE, LM6000PC, 2005, 49.8 MW, 50Hz, Natural Gas

Description

  1. Overview
    1. General electric GELM-6000 power plant, 50 MW, 50 Hz
    2. Model: GELM-6000
    3. 50 MW
    4. 50 Hz
    5. 1 x gas turbine
    6. 1 x HRSG boiler
    7. 1 x steam turbine
    8. 2 x generators
    9. Reference number: L-4320
  2. Engine
    1. General electric GE7LM6000-PC-NDW 602 engine, 50.6 MW, 50 Hz
    2. Model: GE7LM6000-PC NDW 602
    3. 50.6 MW
    4. Reference number: L-4319
  3. Core Engine
    1. GE LM6000PC core engine fired by natural gas
    2. GE
    3. Type: LM6000PS
    4. Core engine
    5. PUC quality natural gas fired only
    6. Engine hours since new 56,022
    7. Total hours since new 128,022
    8. Reference number: P-7944
  4. Barge Mounted Power Plant
    1. Barge mounted power plant, 220 MW, natural gas – GE LM-6000 PC sprint turbines
    2. Required amount of natural gas: 1 mmscmd (approx.)
    3. Total fresh water requirement: 1000 cubic meter per day (approx.)
    4. All turbines and their auxiliaries are mounted on a single floating barge
    5. 4 x GE LM-6000 PC sprint aero derivative gas turbines
    6. 50.8 MW each
    7. 4 x ABB steam generators
    8. 1 x IST steam turbine and generator
    9. 53 MW
    10. 1 x chiller
    11. For cooling the gas turbine intake air for increasing the output
    12. Capacity: 1210 TR
    13. Refrigerant: HFC134a
    14. Compressed air system
    15. 3 x 100% screw type air compressors with 2 x 100% desiccant type dryers
    16. Capacity: 12.7 Nm3 per minute and 8.64 bar g discharge pressure
    17. Electrical system
    18. Generated at 11 kV and evacuated as 220 kV
    19. 2 x step-up transformers 11kV / 220 kV (1 each for 2 gas turbines) and 1 step-up transformers for steam turbine
    20. 2 x auxiliary transformers for stepping down from 11 kV to 6.6 kV
    21. 4 x step-down transformers for stepping down the 6.6 kV to 415V
    22. Demineralization plant
    23. Produces de-mineralized water for generating system in OTSG
    24. Water cooling system
    25. Reference number: L-4427
  5. Power Plant Specifications
    1. GE power plant LM6000, 49.8 MW, year 2005 – 50Hz
    2. Manufacturer: GE
    3. Type of gas turbine: LM6000PC
    4. Running hours: 43970 h
    5. Manufacture year: 2005
    6. Power: 49.8 MW
    7. Commissioning year: 2006
    8. Efficiency: 39%
    9. Fuel: natural gas
    10. Stopped: 10.11.2015
    11. Overhaul: 26000 h
    12. After overhaul: 17970 h
    13. Next overhaul hour: 50000
    14. Consumption worth: 1 MW 278 SM3
    15. Normal stop: 2065
    16. Start: 2625
    17. Frequency: 50 Hz
    18. Reference number: R-6464
  6. Generator
    1. Generator: Brush
    2. Type: turbo generator
    3. Working hours: 43970 saat
    4. Year: 2004
    5. Commissioning year: 2006
    6. Output: 63500 KVA
    7. Volts: 11500
    8. Amps: 3188
    9. P.F: 0.8
    10. Phases/Hz: 3/50
    11. Phase conn: star
    12. Exc. volts: 205
    13. Exc. amps: 1035
    14. Rating: continuous
    15. Frame: BDAX 7- 290ERJT
    16. Spec: I.E.C.34-3
  7. Gear Box
    1. Gear box: Flender Graffenstaden
    2. Year: 2005
    3. Commissioning year: 2006
    4. Working hours: 43970
    5. Rated power: 70000 HP
    6. Rated speed input/output: 3627/3000 RPM
    7. Size: TX61/1CV
    8. Accord standard: API 613/95
  8. Boiler
    1. Boiler brand: Innovative Steam Technologies (IST)
    2. Year: 2005
    3. Commissioning year: 2006
    4. Working hours: 43970
    5. Capacity: 60 tons per hour