NovaStar, SZ109, 25 m3 Capacity, 54 kW, Ethylene Oxide Sterilizer (New)

Description

  1. Overview
    1. SZ109 eo sterilizer
    2. Size: 25 m3
    3. Inner size: 10300 x 1400 x 1750 mm
    4. Installation size: 10750 x 3300 x 2800 mm
    5. Transportation size: chamber 10750 x 2000 x 2500 mm, weight 13500 kg; water tank 1300 x 1000 x 2500 mm, weight 950 kg; door triangle 2400 x 1200 x 300 mm, weight 50 kg x 2
  2. Main Material
    1. Chamber material: inner sus 304 stainless steel, 8 mm thickness; water jacket q235 14# channel steel; insulation layer 100 kg grade mineral wool; outside stainless steel, 1.2 mm thickness; foot q235 16# channel steel.
    2. Door material: door flange sus 304 stainless steel 60x60; door plate sus 304 stainless steel 8 mm thickness; door water jacket sus 304 stainless steel; door sealer silicon.
    3. Water tank: tank material sus 304 stainless steel 5 mm thickness; electrical heat tube stainless steel, 3 kw power each; frame material q235 angle steel 60x60x6; insulation layer 100 kg grade mineral wool.
    4. Vaporization: eo vaporization tube sus 304 stainless steel φ48x3.
    5. Eo vaporization water tank: sus 304 stainless steel 5 mm thickness; insulation layer 100 kg grade mineral wool.
  3. Main Technical Parameters
    1. Sterilization temperature: 30-60 °c (automate); quantity of sensor: 2 for daily monitoring.
    2. Sterilization pressure: -80 to 80 kpa; quantity of sensor: 1; pressure meter: 1.
    3. Sterilization humidity: 35-85% rh adjustable (direct).
    4. Eo concentration: 300-1000 g/m3.
    5. Sterilization time: 3-12 hours.
    6. Pre-vacuum: according to process.
    7. Washing frequency: according to process.
    8. Ventilation time: according to process.
    9. Power supply: three phase five wire 480 v 60 hz.
    10. Power: 54 kw / 25 m3.
    11. Water: 0.15-0.3 mpa.
  4. Main Configuration
    1. Inner chamber uses sus 304 stainless steel, 8 mm thickness, can bear -80 kpa vacuum; outside uses stainless wire drawing board.
    2. Vacuum system (pre-vacuum and wash).
    3. Water tank heating (stainless water tank and water pump) and circulating system (chamber heating, content pre-heating and temperature keeping).
    4. Eo vaporization and automatic feeding system.
    5. Use high efficiency filter at the wash procedure after sterilization.
    6. Automatic steam generator and automatic humidification system.
    7. Pneumatic system and automatic open/close door device (control the valve's open and close, door's open and close, door's lock and door's seal).
    8. Computer control system: win7 os, sterilization parameter and trend (graph) display, control, record, print, save, real time check; more than 10 years retention time.
  5. Additional Information
    1. More information is available upon request.