Multi-pass flue gas travel for maximum heat extraction
Constructed and assembled as a completely packaged unit ready for field connections to the steam supply, return connection, electrical power supply, fuel supply, relief valve discharge, building management controls and flue-gas vent
150 psig steam boiler manufactured in strict accordance with the ASME power boiler code, section I, and bears the ASME “S” stamp for a maximum working pressure of 150 psig
Vessel And Tube Construction
Constructed on a heavy steel frame
Boiler pressure vessel constructed of adequately sized upper and lower drums
A minimum of two downcomers are located inside the furnace chamber to maximize proper thermal internal water circulation
Boiler steam drum outside diameter: no less than 24 in
Steam drum designed for providing steam quality in excess of 99%
Steel water tubes: 1.5 in outside diameter, 0.095 in wall thickness, six-pass, flexible serpentine bend design, not subject to thermal shock damage
Individual water tubes are easily removable and replaceable without welding or rolling
Maximum of two tube configurations
Complete with an adequate number of tappings and inspection opening to facilitate internal boiler inspection and cleaning
Furnace/Combustion Chamber Construction
Access to the furnace/combustion chamber through hinged access doors with an opening of 26 in width x 62 in height to allow for inspection of the interior chamber and the burner head
All remaining panels are individually removable
All access panels are affixed to the pressure vessel frame and insulated with 2 in internal fiber mono block and 2 in high temperature ceramic blanket insulation and are fully gasketed for pressurized firing
The chamber is water-wall design with one side of removable panels
The stationary interior wall is lined with 2 in ceramic blanket insulation
Front and rear wall insulation: 5 in mineral fiber mono block and 2 in ceramic blanket insulation
The chamber and flueways are designed to operate at a positive 0.50 in w.c. at the boiler flue outlet
The boiler will require a “positive pressure” type metal flue
Jacket Construction
Boiler unit includes a metal jacket, 16 gauge, zinc-coated, rust-resistant steel casing, finished with a suitable heat resistant paint and constructed on a structural steel frame and insulated with minimum 1.5 in fiberglass insulation
Complete jacket and insulation is easily removable and reinstalled
Complete with individually removable jacket doors with handles providing easy access to combustion chamber and access panels
Entire tube area is easily accessible for fireside cleaning
All controls are mounted on boiler front
Any external downcomers are provided with factory supplied insulation, jacketing and guards to prevent human contact to high temperature surfaces while boiler is in operation
Steam Boiler Trim
Complete with the following trim and controls:
ASME safety-relief valve(s)
Steam pressure gauge
High limit safety control
Water gauge glass
Low water cutoff and feed pump control
Auxiliary low water cutoff – probe type m/r
Gauge cocks
Gas Burner And Control Equipment
Complete with a UL listed force draft flame retention gas burner
Burner complete with integral motor and blower for supplying sufficient combustion air with normal vent conditions
Fuel: natural gas
Included Controls
Main manual gas shutoff valves
Motorized gas valve operator and auxiliary safety shutoff gas valve
Motorized gas valve with proof of closure operator and auxiliary safety shutoff gas valve
High and low gas pressure switches
Gas pilot shutoff and solenoid valves
Gas pilot ignition assembly with ignition transformer
Pilot and main gas pressure regulators
Burner mounted control panel containing:
Four indicator lights – call for heat, ignition, fuel, and flame safeguard alarm
Air safety switch
Fused on/off switch
Motor starter(s)
Honeywell electronic combustion safety control
Installation Requirement
Must be installed on a concrete pad larger than boiler base according to manufacturer’s written instructions and referenced standards
Condition
Casing newly repaired and painted by a Bryan technician
Blower motor dipped with new bearings installed
Water side hydrostatically tested prior to sale
All controls tested and fully operational
Additional Information
More information is available upon request
Specifications
Drum outside diameter: 24 inches
Tube outside diameter: 1.5 inches
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.